{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,8]],"date-time":"2026-06-08T22:57:30Z","timestamp":1780959450320,"version":"3.54.1"},"reference-count":35,"publisher":"SLACK, Inc.","issue":"4","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Refract Surg"],"published-print":{"date-parts":[[2010,4]]},"abstract":"<jats:sec>\n            <jats:title>PURPOSE:<\/jats:title>\n            <jats:p>To investigate changes in Ocular Response Analyzer parameters after myopic LASIK.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>METHODS:<\/jats:title>\n            <jats:p>Thirty myopic patients (60 eyes) undergoing bilateral LASIK were studied prospectively. Corneal hysteresis, corneal resistance factor, Goldmann-correlated intraocular pressure (IOPg), and corneal-compensated IOP (IOPcc) measurements were obtained with the Ocular Response Analyzer before and after LASIK. Central corneal thickness and corneal flap thickness were also measured with optical coherence tomography.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>RESULTS:<\/jats:title>\n            <jats:p>\n              Compared with preoperative baseline values, corneal hysteresis, corneal resistance factor, IOPg, IOPcc, and central corneal thickness decreased postoperatively (\n              <jats:italic>P<\/jats:italic>\n              &lt;.01). Corneal hysteresis (CH), corneal resistance factor (CRF), IOPg, IOPcc, and central corneal thickness (CCT) increased between 10 days and 3 months (post-hoc,\n              <jats:italic>P<\/jats:italic>\n              &lt;.05). (The differences between the preoperative values and those at 3 months postoperatively are denoted by \u0394.) The correlation of the ablation depth was stronger for \u0394CRF (r=0.457) than for \u0394CH (r=0.271). \u0394CH was negatively correlated to flap thickness (r=\u22120.361) and the ratio of flap thickness to preoperative central corneal thickness (r=\u22120.442) whereas \u0394CRF was not. \u0394CH was positively correlated with \u0394IOPcc, and \u0394CRF was positively correlated with \u0394IOPg. \u0394IOPg was positively correlated with \u0394CCT whereas \u0394IOPcc was not.\n            <\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>CONCLUSIONS:<\/jats:title>\n            <jats:p>\n              Corneal biomechanical properties measured by corneal hysteresis and corneal resistance factor were decreased at 10 days after LASIK. Minimal recovery (approximately 10% of the changes) was achieved by 3 months. The changes in biomechanical properties may affect IOP measurement. [\n              <jats:italic>J Refract Surg<\/jats:italic>\n              . 2010;26:279\u2013288.]\n            <\/jats:p>\n          <\/jats:sec>","DOI":"10.3928\/1081597x-20100218-04","type":"journal-article","created":{"date-parts":[[2010,4,23]],"date-time":"2010-04-23T15:20:57Z","timestamp":1272036057000},"page":"279-288","source":"Crossref","is-referenced-by-count":32,"title":["Changes in Ocular Response Analyzer Parameters After LASIK"],"prefix":"10.3928","volume":"26","author":[{"given":"Shihao","family":"Chen","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ding","family":"Chen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jianhua","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fan","family":"Lu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Qinmei","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jia","family":"Qu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"2308","reference":[{"key":"e_1_3_3_2_2","doi-asserted-by":"publisher","DOI":"10.3109\/08820539809059822"},{"key":"e_1_3_3_3_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(01)00831-8"},{"key":"e_1_3_3_4_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(00)00434-X"},{"key":"e_1_3_3_5_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081-597X-20060501-03"},{"key":"e_1_3_3_6_2","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.03-1088"},{"key":"e_1_3_3_7_2","doi-asserted-by":"publisher","DOI":"10.1115\/1.2891373"},{"key":"e_1_3_3_8_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2004.10.038"},{"key":"e_1_3_3_9_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2004.09.042"},{"key":"e_1_3_3_10_2","doi-asserted-by":"publisher","DOI":"10.1097\/00003226-200201000-00015"},{"key":"e_1_3_3_11_2","doi-asserted-by":"publisher","DOI":"10.1016\/0014-4835(88)90016-4"},{"key":"e_1_3_3_12_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2006.09.036"},{"key":"e_1_3_3_13_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2006.07.058"},{"key":"e_1_3_3_14_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20080401-09"},{"key":"e_1_3_3_15_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1600-0420.2007.01023.x"},{"key":"e_1_3_3_16_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2004.10.044"},{"key":"e_1_3_3_17_2","first-page":"151","article-title":"Dynamic mechanical spectroscopy of the cornea for measurement of its viscoelastic properties in vitro","volume":"4","author":"Soergel F","year":"1995","unstructured":"Soergel F, Jean B, Seiler T, Bende T, Mucke S, Pechhold W, Pels L. Dynamic mechanical spectroscopy of the cornea for measurement of its viscoelastic properties in vitro. Ger J Ophthalmol. 1995;4:151\u2013156.","journal-title":"Ger J Ophthalmol"},{"key":"e_1_3_3_18_2","first-page":"2266","article-title":"Methodology for cornea compensated IOP and corneal resistance factor for the Reichert ocular response analyzer","volume":"47","author":"Luce D","year":"2006","unstructured":"Luce D. Methodology for cornea compensated IOP and corneal resistance factor for the Reichert ocular response analyzer. ARVO Meeting Abstracts. 2006;47:2266.","journal-title":"ARVO Meeting Abstracts"},{"key":"e_1_3_3_19_2","doi-asserted-by":"publisher","DOI":"10.1001\/archopht.1994.01090240090031"},{"key":"e_1_3_3_20_2","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.02-0343"},{"key":"e_1_3_3_21_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0161-6420(99)00022-6"},{"key":"e_1_3_3_22_2","first-page":"1791","article-title":"Repeatability and reproducibility of corneal thickness measurements by optical coherence tomography","volume":"43","author":"Muscat S","year":"2002","unstructured":"Muscat S, McKay N, Parks S, Kemp E, Keating D. Repeatability and reproducibility of corneal thickness measurements by optical coherence tomography. Invest Ophthalmol Vis Sci. 2002;43:1791\u20131795.","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"e_1_3_3_23_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2007.04.021"},{"key":"e_1_3_3_24_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2004.09.043"},{"key":"e_1_3_3_25_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081-597X-20070101-12"},{"key":"e_1_3_3_26_2","doi-asserted-by":"publisher","DOI":"10.1097\/01.opx.0000221388.26031.23"},{"key":"e_1_3_3_27_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0002-9394(01)01382-4"},{"key":"e_1_3_3_28_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2006.12.031"},{"key":"e_1_3_3_29_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2007.05.023"},{"key":"e_1_3_3_30_2","doi-asserted-by":"publisher","DOI":"10.1177\/112067210501500113"},{"key":"e_1_3_3_31_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(98)80222-8"},{"key":"e_1_3_3_32_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2003.12.033"},{"key":"e_1_3_3_33_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2004.09.031"},{"key":"e_1_3_3_34_2","doi-asserted-by":"publisher","DOI":"10.1097\/01.ijg.0000212268.42606.97"},{"key":"e_1_3_3_35_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1442-9071.2006.01185.x"},{"key":"e_1_3_3_36_2","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.06-0507"}],"container-title":["Journal of Refractive Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.healio.com\/doiresolver?doi=10.3928\/1081597X-20100218-04","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,5,2]],"date-time":"2023-05-02T22:34:55Z","timestamp":1683066895000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.healio.com\/doi\/10.3928\/1081597X-20100218-04"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2010,4]]},"references-count":35,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2010,4]]}},"alternative-id":["10.3928\/1081597X-20100218-04"],"URL":"https:\/\/doi.org\/10.3928\/1081597x-20100218-04","relation":{},"ISSN":["1081-597X"],"issn-type":[{"value":"1081-597X","type":"print"}],"subject":[],"published":{"date-parts":[[2010,4]]}}}