{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,19]],"date-time":"2026-11-19T14:11:13Z","timestamp":1795097473533,"version":"4.10.3"},"reference-count":66,"publisher":"SLACK, Inc.","issue":"3","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Refract Surg"],"published-print":{"date-parts":[[2011,3]]},"abstract":"<jats:sec>\n                    <jats:title>Purpose:<\/jats:title>\n                    <jats:p>To compare corneal hysteresis (CH) and corneal resistance factor (CRF) in eyes with keratoconus with a central corneal thickness (CCT) \u2265520 \u03bcm with CH and CRF in matched controls, and to estimate the sensitivity and specificity of these parameters for discriminating between the two groups.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>This prospective, comparative case series comprised 19 eyes of 19 patients with keratoconus with CCT \u2265520 \u03bcm and 19 eyes of 19 healthy sex-, age-, and CCT-matched patients who underwent a complete clinical eye examination, corneal topography, tomography, and biomechanical evaluation. The receiver operating characteristic (ROC) curve was used to identify cutoff points that maximized the sensitivity and specificity for discriminating between groups.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      Central corneal thickness was 543.1\u00b113.9 \u03bcm (range: 520 to 568 \u03bcm) in the keratoconus group and 545\u00b112.5 \u03bcm (range: 527 to 575 \u03bcm) in the control group (\n                      <jats:italic>P<\/jats:italic>\n                      =.6017). Corneal hysteresis was 9.22\u00b11.44 mmHg (range: 6.2 to 11.35 mmHg) in the keratoconus group and 10.58\u00b11.91 mmHg (range: 7.34 to 13.53 mmHg) in the control group (\n                      <jats:italic>P<\/jats:italic>\n                      =.0075). Corneal resistance factor was 8.62\u00b11.52 mmHg (range: 5.60 to 11.20 mmHg) in the keratoconus group and 10.30\u00b11.92 mmHg (range: 6.95 to 14.12 mmHg) in the control group (\n                      <jats:italic>P<\/jats:italic>\n                      =.0049). The ROC curve analyses showed a poor overall predictive accuracy of CH (cutoff, 9.90 mmHg; sensitivity, 78.9%; specificity, 63.2%; test accuracy, 71.05%) and CRF (cutoff, 8.90 mmHg; sensitivity, 68.4%; specificity, 78.9%; test accuracy, 73.65%) for detecting keratoconus in the eyes studied.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions:<\/jats:title>\n                    <jats:p>Corneal hysteresis and CRF were statistically lower in the keratoconus group compared with the control group. Given the large overlap, both CH and CRF had low sensitivity and specificity for discriminating between groups.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.3928\/1081597x-20100415-02","type":"journal-article","created":{"date-parts":[[2010,5,19]],"date-time":"2010-05-19T15:54:06Z","timestamp":1274284446000},"page":"209-215","source":"Crossref","is-referenced-by-count":82,"title":["Ocular Response Analyzer Measurements in Keratoconus with Normal Central Corneal Thickness Compared with Matched Normal Control Eyes"],"prefix":"10.3928","volume":"27","author":[{"given":"Bruno M.","family":"Fontes","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"suffix":"Jr","given":"Renato","family":"Ambr\u00f3sio","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Guillermo Coca","family":"Velarde","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Walton","family":"Nos\u00e9","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"2308","reference":[{"key":"e_1_3_2_2_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0039-6257(00)00110-7"},{"key":"e_1_3_2_3_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20080601-09"},{"key":"e_1_3_2_4_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.exer.2003.09.017"},{"key":"e_1_3_2_5_2","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.05-0893"},{"key":"e_1_3_2_6_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2006.06.025"},{"key":"e_1_3_2_7_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2008.09.048"},{"key":"e_1_3_2_8_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2009.01.022"},{"key":"e_1_3_2_9_2","doi-asserted-by":"publisher","DOI":"10.1097\/OPX.0b013e318196a737"},{"key":"e_1_3_2_10_2","doi-asserted-by":"publisher","DOI":"10.1590\/S0004-27492006000400023"},{"key":"e_1_3_2_11_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2007.06.020"},{"key":"e_1_3_2_12_2","doi-asserted-by":"publisher","DOI":"10.1097\/ICO.0b013e3181839b06"},{"key":"e_1_3_2_13_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1442-9071.2009.02009.x"},{"key":"e_1_3_2_14_2","doi-asserted-by":"publisher","DOI":"10.1097\/ICL.0b013e318198be6e"},{"key":"e_1_3_2_15_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2009.01.009"},{"key":"e_1_3_2_16_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1442-9071.2009.01908.x"},{"key":"e_1_3_2_17_2","doi-asserted-by":"publisher","DOI":"10.1097\/ICO.0b013e31817f815a"},{"key":"e_1_3_2_18_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2007.07.021"},{"key":"e_1_3_2_19_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2009.05.006"},{"key":"e_1_3_2_20_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2008.06.008"},{"key":"e_1_3_2_21_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2006.02.037"},{"key":"e_1_3_2_22_2","doi-asserted-by":"publisher","DOI":"10.1097\/01.icu.0000243015.51886.3a"},{"key":"e_1_3_2_23_2","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.06-0557"},{"key":"e_1_3_2_24_2","doi-asserted-by":"publisher","DOI":"10.1136\/bjo.2003.034520"},{"key":"e_1_3_2_25_2","doi-asserted-by":"publisher","DOI":"10.1097\/00003226-200210000-00008"},{"key":"e_1_3_2_26_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0039-6257(97)00119-7"},{"key":"e_1_3_2_27_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2009.01.008"},{"key":"e_1_3_2_28_2","doi-asserted-by":"publisher","DOI":"10.1097\/OPX.0b013e3181784673"},{"key":"e_1_3_2_29_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.visres.2008.06.020"},{"key":"e_1_3_2_30_2","doi-asserted-by":"publisher","DOI":"10.1097\/ICO.0b013e318190734d"},{"key":"e_1_3_2_31_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2008.12.013"},{"key":"e_1_3_2_32_2","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.08-3312"},{"key":"e_1_3_2_33_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2007.12.034"},{"key":"e_1_3_2_34_2","doi-asserted-by":"publisher","DOI":"10.1097\/OPX.0b013e31818e8abe"},{"key":"e_1_3_2_35_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2008.05.026"},{"key":"e_1_3_2_36_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00417-008-0864-x"},{"key":"e_1_3_2_37_2","doi-asserted-by":"publisher","DOI":"10.1097\/OPX.0b013e3181783a5f"},{"key":"e_1_3_2_38_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20081101-14"},{"key":"e_1_3_2_39_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2008.02.011"},{"key":"e_1_3_2_40_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2007.04.021"},{"key":"e_1_3_2_41_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2006.07.058"},{"key":"e_1_3_2_42_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2007.05.023"},{"key":"e_1_3_2_43_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081-597X-20000701-03"},{"key":"e_1_3_2_44_2","doi-asserted-by":"publisher","DOI":"10.1136\/bjo.2008.140012"},{"key":"e_1_3_2_45_2","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.09-3689"},{"key":"e_1_3_2_46_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1442-9071.2009.02005.x"},{"key":"e_1_3_2_47_2","doi-asserted-by":"publisher","DOI":"10.1136\/bjo.2008.144253"},{"key":"e_1_3_2_48_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2004.10.044"},{"key":"e_1_3_2_49_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.survophthal.2007.08.004"},{"key":"e_1_3_2_50_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2007.07.008"},{"key":"e_1_3_2_51_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.clae.2008.12.009"},{"key":"e_1_3_2_52_2","doi-asserted-by":"publisher","DOI":"10.1136\/bjo.2007.136473"},{"key":"e_1_3_2_53_2","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.04-0694"},{"key":"e_1_3_2_54_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20091105-04"},{"key":"e_1_3_2_55_2","first-page":"xvi","volume-title":"Corneal Topography in the Wavefront Era: A Guide for Clinical Application","author":"Wang M","year":"2006","unstructured":"Wang M. Corneal Topography in the Wavefront Era: A Guide for Clinical Application. Thorofare, NJ: SLACK Incorporated; 2006; xvi."},{"key":"e_1_3_2_56_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2008.10.019"},{"key":"e_1_3_2_57_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1442-9071.2008.01821.x"},{"key":"e_1_3_2_58_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.clae.2009.02.005"},{"key":"e_1_3_2_59_2","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.07-0280"},{"key":"e_1_3_2_60_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1600-0420.2007.01023.x"},{"key":"e_1_3_2_61_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2006.09.036"},{"key":"e_1_3_2_62_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.clae.2006.09.006"},{"key":"e_1_3_2_63_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2005.12.007"},{"key":"e_1_3_2_64_2","article-title":"Methodology for cornea compensated IOP and corneal resistance factor for the Reichert Ocular Response Analyzer","volume":"47","author":"Luce D","year":"2006","unstructured":"Luce D. Methodology for cornea compensated IOP and corneal resistance factor for the Reichert Ocular Response Analyzer. Invest Ophthalmol Vis Sci. 2006;47:E-Abstract 2266.","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"e_1_3_2_65_2","doi-asserted-by":"publisher","DOI":"10.1097\/01.icu.0000233954.86723.25"},{"key":"e_1_3_2_66_2","doi-asserted-by":"publisher","DOI":"10.1097\/01.ico.0000226359.26678.d1"},{"key":"e_1_3_2_67_2","volume-title":"Presented at: American Society of Cataract and Refractive Surgery meeting","author":"Luce D","unstructured":"Luce D. ORA waveform analysis and beyond. Presented at: American Society of Cataract and Refractive Surgery meeting; April 3\u20138, 2009; San Francisco, California."}],"container-title":["Journal of Refractive Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.healio.com\/doiresolver?doi=10.3928\/1081597X-20100415-02","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,5,3]],"date-time":"2023-05-03T03:18:26Z","timestamp":1683083906000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.healio.com\/doi\/10.3928\/1081597X-20100415-02"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2011,3]]},"references-count":66,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2011,3]]}},"alternative-id":["10.3928\/1081597X-20100415-02"],"URL":"https:\/\/doi.org\/10.3928\/1081597x-20100415-02","relation":{},"ISSN":["1081-597X"],"issn-type":[{"value":"1081-597X","type":"print"}],"subject":[],"published":{"date-parts":[[2011,3]]}}}