{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,6]],"date-time":"2026-03-06T23:54:46Z","timestamp":1772841286924,"version":"3.50.1"},"reference-count":59,"publisher":"SLACK, Inc.","issue":"2","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Refract Surg"],"published-print":{"date-parts":[[2011,2]]},"abstract":"<jats:sec>\n            <jats:title>Purpose:<\/jats:title>\n            <jats:p>To evaluate the effective optical zone (the part of the ablation that receives full correction) among eyes that underwent laser epithelial keratomileusis (LASEK)\/epi-LASEK treatments for myopic astigmatism.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods:<\/jats:title>\n            <jats:p>Twenty LASEK\/epi-LASEK treatments with a mean spherical equivalent refraction (SE) of \u22125.49\u00b12.35 diopters (D) performed using the SCHWIND AMARIS system were retrospectively evaluated at 6-month follow-up. In all cases, pre- and postoperative corneal wavefront analyses were performed with the Keratron Scout (OPTIKON 2000). Effective optical zone values were evaluated from the changes of root-mean-square (RMS) of higher order wavefront aberration (\u0394RMSho), spherical aberration (\u0394SphAb), and RMS of the change of higher order wavefront aberration (RMS[\u0394HOAb]). Correlations of effective optical zone with planned optical zone and SE correction were analyzed using a bilinear function as well as calculations of the isometric lines for which effective optical zone equals planned optical zone and of the nomogram planned optical zone to achieve an intended effective optical zone.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>\n              At 6 months, SE was \u22120.05\u00b10.43 D, with 90% of eyes within \u00b10.50 D. Mean higher order wavefront aberration RMS increased 0.12 \u03bcm, spherical aberration 0.09 \u03bcm, and coma 0.04 \u03bcm after treatment (6-mm diameter). Mean planned optical zone was 6.76\u00b10.25 mm, whereas mean EOZ\n              <jats:sub>\u0394RMSho<\/jats:sub>\n              was 6.74\u00b10.66 mm (bilinear correlation\n              <jats:italic>P<\/jats:italic>\n              &lt;.005), EOZ\n              <jats:sub>\u0394SphAb<\/jats:sub>\n              was 6.83\u00b10.58 mm (bilinear correlation\n              <jats:italic>P<\/jats:italic>\n              &lt;.0001), and EOZ\n              <jats:sub>RMS(\u0394HOAb)<\/jats:sub>\n              was 6.42\u00b10.58 mm (significantly smaller,\n              <jats:italic>P<\/jats:italic>\n              &lt;.05; bilinear correlation\n              <jats:italic>P<\/jats:italic>\n              &lt;.0005).\n            <\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions:<\/jats:title>\n            <jats:p>\n              The EOZ\n              <jats:sub>\u0394RMSho<\/jats:sub>\n              and EOZ\n              <jats:sub>\u0394SphAb<\/jats:sub>\n              were similar to the planned optical zone, whereas EOZ\n              <jats:sub>RMS(\u0394HOAb)<\/jats:sub>\n              was significantly smaller. Differences between effective optical zone and planned optical zone were larger for smaller planned optical zone or larger SE corrections. Planned optical zones &gt;6.75 mm result in effective optical zones at least as large as planned optical zones. For optical zones &lt;6.75 mm, a nomogram should be applied.\n            <\/jats:p>\n          <\/jats:sec>","DOI":"10.3928\/1081597x-20100428-03","type":"journal-article","created":{"date-parts":[[2010,5,19]],"date-time":"2010-05-19T19:54:06Z","timestamp":1274298846000},"page":"135-146","source":"Crossref","is-referenced-by-count":25,"title":["Aspheric Optical Zones: The Effective Optical Zone with the SCHWIND AMARIS"],"prefix":"10.3928","volume":"27","author":[{"given":"Massimo","family":"Camellin","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Samuel","family":"Arba Mosquera","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"2308","reference":[{"key":"e_1_3_2_2_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(88)80063-4"},{"key":"e_1_3_2_3_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0002-9394(21)00230-0"},{"key":"e_1_3_2_4_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0161-6420(99)00043-3"},{"key":"e_1_3_2_5_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0161-6420(00)00059-2"},{"key":"e_1_3_2_6_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081-597X-19900901-14"},{"key":"e_1_3_2_7_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0161-6420(95)30927-X"},{"key":"e_1_3_2_8_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081-597X-19940301-07"},{"issue":"7","key":"e_1_3_2_9_2","first-page":"2275","article-title":"Optical zone diameters for photorefractive corneal surgery","volume":"34","author":"Roberts CW","year":"1993","unstructured":"Roberts CW, Koester CJ. Optical zone diameters for photorefractive corneal surgery. Invest Ophthalmol Vis Sci. 1993;34(7):2275\u20132281.","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"e_1_3_2_10_2","doi-asserted-by":"publisher","DOI":"10.1136\/bjo.79.10.881"},{"issue":"13","key":"e_1_3_2_11_2","first-page":"1396","article-title":"Ocular aberrations before and after myopic corneal refractive surgery: LASIK-induced changes measured with laser ray tracing","volume":"42","author":"Moreno-Barriuso E","year":"2001","unstructured":"Moreno-Barriuso E, Lloves JM, Marcos S. Ocular aberrations before and after myopic corneal refractive surgery: LASIK-induced changes measured with laser ray tracing. Invest Ophthalmol Vis Sci. 2001;42(13):1396\u20131403.","journal-title":"Invest Ophthalmol Vis Sci"},{"issue":"13","key":"e_1_3_2_12_2","first-page":"3349","article-title":"Optical response to LASIK for myopia from total and corneal aberration measurements","volume":"42","author":"Marcos S","year":"2001","unstructured":"Marcos S, Barbero S, Llorente L, Merayo J. Optical response to LASIK for myopia from total and corneal aberration measurements. Invest Ophthalmol Vis Sci. 2001;42(13):3349\u20133356.","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"e_1_3_2_13_2","doi-asserted-by":"publisher","DOI":"10.1364\/JOSAA.11.001949"},{"key":"e_1_3_2_14_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081-597X-20030901-06"},{"key":"e_1_3_2_15_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(00)00827-0"},{"key":"e_1_3_2_16_2","first-page":"70","volume-title":"Corneal contribution to the wavefront aberration of the eye [PhD dissertation]","author":"Salmon TO","year":"1999","unstructured":"Salmon TO. Corneal contribution to the wavefront aberration of the eye [PhD dissertation]. Bloomington, IN: Indiana University; 1999:70."},{"key":"e_1_3_2_17_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081-597X-20030301-04"},{"key":"e_1_3_2_18_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2004.01.026"},{"key":"e_1_3_2_19_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2006.01.049"},{"key":"e_1_3_2_20_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081-597X-20040901-03"},{"key":"e_1_3_2_21_2","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.08-2316"},{"key":"e_1_3_2_22_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081-597X-20030901-17"},{"key":"e_1_3_2_23_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081-597X-20010901-15"},{"key":"e_1_3_2_24_2","doi-asserted-by":"publisher","DOI":"10.1063\/1.1502192"},{"key":"e_1_3_2_25_2","doi-asserted-by":"publisher","DOI":"10.1364\/OPEX.13.000336"},{"key":"e_1_3_2_26_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2004.04.073"},{"key":"e_1_3_2_27_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081-597X-20030501-10"},{"key":"e_1_3_2_28_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081-597X-20031101-09"},{"issue":"1","key":"e_1_3_2_29_2","first-page":"S57","article-title":"Epi-LASIK versus epi-LASEK","volume":"24","author":"Camellin M","year":"2008","unstructured":"Camellin M, Wyler D. Epi-LASIK versus epi-LASEK. J Refract Surg. 2008;24(1):S57\u2013S63.","journal-title":"J Refract Surg"},{"key":"e_1_3_2_30_2","doi-asserted-by":"publisher","DOI":"10.1097\/00006324-199711000-00021"},{"key":"e_1_3_2_31_2","volume-title":"Letterproeven tot Bepaling der Gezichtsscherpte","author":"Snellen H","year":"1862","unstructured":"Snellen H. Letterproeven tot Bepaling der Gezichtsscherpte. Utrecht, The Netherlands: Weyers; 1862."},{"key":"e_1_3_2_32_2","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.08-2176"},{"key":"e_1_3_2_33_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2004.10.046"},{"key":"e_1_3_2_34_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2003.09.008"},{"issue":"4","key":"e_1_3_2_35_2","first-page":"941","article-title":"Analysis of customized ablations: theoretical limitations of increasing negative asphericity","volume":"43","author":"Gatinel D","year":"2002","unstructured":"Gatinel D, Malet J, Hoang-Xuan T, Azar D. Analysis of customized ablations: theoretical limitations of increasing negative asphericity. Invest Ophthalmol Vis Sci. 2002;43(4):941\u2013948.","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"e_1_3_2_36_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081-597X-20070501-15"},{"key":"e_1_3_2_37_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00347-008-1717-z"},{"key":"e_1_3_2_38_2","doi-asserted-by":"publisher","DOI":"10.1364\/OE.16.003877"},{"key":"e_1_3_2_39_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(01)01163-4"},{"key":"e_1_3_2_40_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081-597X-20030101-04"},{"key":"e_1_3_2_41_2","doi-asserted-by":"publisher","DOI":"10.1007\/BF02181196"},{"key":"e_1_3_2_42_2","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.08-1766"},{"key":"e_1_3_2_43_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081-597X-20050101-08"},{"key":"e_1_3_2_44_2","doi-asserted-by":"publisher","DOI":"10.1093\/mnras\/94.5.377"},{"key":"e_1_3_2_45_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081-597X-20020901-30"},{"key":"e_1_3_2_46_2","volume-title":"Presented at: 8th International Congress on Wavefront Sensing and Optimized Refractive Corrections","author":"Drum B","unstructured":"Drum B. The evolution of the optical zone in corneal refractive surgery. Presented at: 8th International Congress on Wavefront Sensing and Optimized Refractive Corrections; February 22\u201325, 2007; Santa Fe, NM."},{"key":"e_1_3_2_47_2","doi-asserted-by":"publisher","DOI":"10.1364\/JOSAA.19.002329"},{"key":"e_1_3_2_48_2","doi-asserted-by":"publisher","DOI":"10.1097\/00003226-200105000-00011"},{"key":"e_1_3_2_49_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0002-9394(14)72896-X"},{"key":"e_1_3_2_50_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0161-6420(99)90105-7"},{"key":"e_1_3_2_51_2","doi-asserted-by":"publisher","DOI":"10.1364\/OE.14.006142"},{"key":"e_1_3_2_52_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081-597X-20011101-05"},{"key":"e_1_3_2_53_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0161-6420(99)90083-0"},{"key":"e_1_3_2_54_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2007.04.043"},{"key":"e_1_3_2_55_2","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.06-0867"},{"key":"e_1_3_2_56_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081-597X-20050301-07"},{"key":"e_1_3_2_57_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081-597X-20040701-06"},{"key":"e_1_3_2_58_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081-597X-20030901-07"},{"key":"e_1_3_2_59_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2004.10.043"},{"key":"e_1_3_2_60_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(13)80400-2"}],"container-title":["Journal of Refractive Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.slackinc.com\/doi\/resolver.asp?doi=10.3928\/1081597X-20100428-03","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,5,3]],"date-time":"2023-05-03T11:53:06Z","timestamp":1683114786000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.healio.com\/doi\/10.3928\/1081597X-20100428-03"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2011,2]]},"references-count":59,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2011,2]]}},"alternative-id":["10.3928\/1081597X-20100428-03"],"URL":"https:\/\/doi.org\/10.3928\/1081597x-20100428-03","relation":{},"ISSN":["1081-597X"],"issn-type":[{"value":"1081-597X","type":"print"}],"subject":[],"published":{"date-parts":[[2011,2]]}}}