{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,28]],"date-time":"2026-02-28T05:10:57Z","timestamp":1772255457109,"version":"3.50.1"},"reference-count":17,"publisher":"SLACK, Inc.","issue":"4","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Refract Surg"],"published-print":{"date-parts":[[2011,4]]},"abstract":"<jats:sec>\n                    <jats:title>Purpose:<\/jats:title>\n                    <jats:p>To compare wavefront-guided and wavefront-optimized LASIK in patients with myopic astigmatism up to \u22127.00 diopters (D) sphere and 3.00 D cylinder.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>In this prospective, comparative study, 41 patients had wavefront-guided LASIK in one eye and wavefront-optimized LASIK in the fellow eye. The LASIK flap was created with a Hansatome XP microkeratome (Bausch &amp; Lomb). The ALLEGRETTO Concerto excimer laser (WaveLight Laser Technologie AG) was used for photoablation. Pupil centroid shift and cyclotorsion were not compensated in the wavefront-guided treatments. The ALLEGRETTO Wave analyzer was used to measure ocular wavefront aberrations, and the CSV-1000 instrument (VectorVision) was used to measure contrast sensitivity before and 1 and 3 months after LASIK.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      Preoperative mean spherical equivalent refraction was \u22124.25\u00b11.19 D (range: \u22127.50 to \u22122.50 D) and \u22124.15\u00b11.21 D (range: \u22127.13 to \u22121.75 D) in the wavefront-guided and wavefront-optimized groups, respectively. Three months postoperatively, 33 (89.2%) eyes in the wavefront-guided group and 31 (83.8%) eyes in the wavefront-optimized group had uncorrected distance visual acuity of 20\/20. Higher order aberrations increased from 0.28\u00b10.08 \u03bcm (range: 0.13 to 0.48 \u03bcm) and 0.26\u00b10.08 \u03bcm (range: 0.13 to 0.55 \u03bcm) to 0.45\u00b10.17 \u03bcm (range: 0.18 to 0.71 \u03bcm) and 0.45\u00b10.16 \u03bcm (range: 0.21 to 0.84 \u03bcm) in the wavefront-guided and wavefront-optimized groups, respectively. Except for C6 trefoil (\n                      <jats:italic>P<\/jats:italic>\n                      =.006), all Zernike polynomials increased in both groups postoperatively with no statistical difference between groups in spherical aberration (\n                      <jats:italic>P<\/jats:italic>\n                      =.41), C7 coma (\n                      <jats:italic>P<\/jats:italic>\n                      =.67), C8 coma (\n                      <jats:italic>P<\/jats:italic>\n                      =.79), and trefoil (\n                      <jats:italic>P<\/jats:italic>\n                      =.82). Contrast sensitivity did not decrease in either group and no statistically significant differences between groups were noted.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions:<\/jats:title>\n                    <jats:p>Higher order aberrations, especially spherical aberration, increasd approximately the same amount in both groups.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.3928\/1081597x-20100812-02","type":"journal-article","created":{"date-parts":[[2010,9,14]],"date-time":"2010-09-14T11:14:28Z","timestamp":1284462868000},"page":"245-250","source":"Crossref","is-referenced-by-count":28,"title":["Wavefront-Guided vs Wavefront-Optimized LASIK: A Randomized Clinical Trial Comparing Contralateral Eyes"],"prefix":"10.3928","volume":"27","author":[{"given":"Mohammad","family":"Miraftab","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mohammad A.","family":"Seyedian","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hassan","family":"Hashemi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"2308","reference":[{"key":"e_1_3_2_2_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2004.01.026"},{"key":"e_1_3_2_3_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2008.04.010"},{"key":"e_1_3_2_4_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2007.10.028"},{"issue":"2","key":"e_1_3_2_5_2","doi-asserted-by":"crossref","first-page":"S217","DOI":"10.3928\/1081-597X-20030302-08","article-title":"Comparison of conventional versus wavefront-guided laser in situ keratomileusis in the same patient","volume":"19","author":"Phusitphoykai N","year":"2003","unstructured":"Phusitphoykai N, Tungsiripat T, Siriboonkoom J, Vongthongsri A. Comparison of conventional versus wavefront-guided laser in situ keratomileusis in the same patient. J Refract Surg. 2003;19(2 Suppl):S217\u2013S220.","journal-title":"J Refract Surg"},{"key":"e_1_3_2_6_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081-597X-20040901-03"},{"key":"e_1_3_2_7_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081-597X-20040901-04"},{"key":"e_1_3_2_8_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081-597X-20010901-06"},{"key":"e_1_3_2_9_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(01)00996-8"},{"key":"e_1_3_2_10_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081-597X-20010501-05"},{"key":"e_1_3_2_11_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0161-6420(02)01013-8"},{"key":"e_1_3_2_12_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(00)00884-1"},{"key":"e_1_3_2_13_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(02)01322-6"},{"key":"e_1_3_2_14_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0161-6420(01)00588-7"},{"key":"e_1_3_2_15_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(00)00707-0"},{"issue":"2","key":"e_1_3_2_16_2","doi-asserted-by":"crossref","first-page":"S190","DOI":"10.3928\/1081-597X-20030302-04","article-title":"Early results of Nidek customized aspheric transition zones (CATz) in laser in situ keratomileusis","volume":"19","author":"Kermani O","year":"2003","unstructured":"Kermani O, Schmiedt K, Oberheide U, Gerten G. Early results of Nidek customized aspheric transition zones (CATz) in laser in situ keratomileusis. J Refract Surg. 2003;19(2 Suppl):S190\u2013S194.","journal-title":"J Refract Surg"},{"key":"e_1_3_2_17_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2005.11.026"},{"issue":"4","key":"e_1_3_2_18_2","first-page":"S424","article-title":"Wavefront-optimized versus wavefront-guided LASIK for myopic astigmatism with the ALLEGRETTO WAVE: three-month results of a prospective FDA trial","volume":"24","author":"Stonecipher KG","year":"2008","unstructured":"Stonecipher KG, Kezirian GM. Wavefront-optimized versus wavefront-guided LASIK for myopic astigmatism with the ALLEGRETTO WAVE: three-month results of a prospective FDA trial. J Refract Surg. 2008;24(4):S424\u2013S430.","journal-title":"J Refract Surg"}],"container-title":["Journal of Refractive Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.slackinc.com\/doi\/resolver.asp?doi=10.3928\/1081597X-20100812-02","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,5,3]],"date-time":"2023-05-03T03:19:10Z","timestamp":1683083950000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.healio.com\/doi\/10.3928\/1081597X-20100812-02"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2011,4]]},"references-count":17,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2011,4]]}},"alternative-id":["10.3928\/1081597X-20100812-02"],"URL":"https:\/\/doi.org\/10.3928\/1081597x-20100812-02","relation":{"has-review":[{"id-type":"doi","id":"10.3410\/f.9961956.10694054","asserted-by":"object"}]},"ISSN":["1081-597X"],"issn-type":[{"value":"1081-597X","type":"print"}],"subject":[],"published":{"date-parts":[[2011,4]]}}}