{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,9]],"date-time":"2026-03-09T15:39:08Z","timestamp":1773070748238,"version":"3.50.1"},"reference-count":53,"publisher":"SLACK, Inc.","issue":"6","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Refract Surg"],"published-print":{"date-parts":[[2011,6]]},"abstract":"<jats:sec>\n            <jats:title>Purpose:<\/jats:title>\n            <jats:p>To determine the spherical wave aberration of the human eye based on corneal topography.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods:<\/jats:title>\n            <jats:p>Based on the pre- and postoperative status of 146 consecutive eyes (median patient age 36 years), the correlations between spherical aberration and asphericity and between corneal and ocular spherical aberrations were determined using simple linear regression methods. The asphericity (Q) values for which spherical aberration equals zero as well as the reference Q values for which corneal spherical aberration equals ocular spherical aberration have been determined. Patients underwent LASIK using the AMARIS excimer laser platform (SCHWIND eye-tech-solutions). All ablations were based on aspheric aberration-neutral profiles.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>\n              Corneal and ocular spherical aberrations correlate well with Q value and the value\n              <jats:italic>p<\/jats:italic>\n              \u00b7\n              <jats:italic>R<\/jats:italic>\n              <jats:sup>\u22123<\/jats:sup>\n              in patients before and after LASIK for myopic astigmatism. A Q value of \u22120.19 to \u22120.27 can provide zero ocular spherical aberration in patients before and after LASIK for myopic astigmatism. Ocular spherical aberration is induced at a rate of half the induced corneal spherical aberration. A reference Q value of \u22120.12 to +0.01 can provide corneal spherical aberration equal to ocular spherical aberration in patients before and after LASIK for myopic astigmatism.\n            <\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions:<\/jats:title>\n            <jats:p>Ocular and corneal wave aberrations are two different concepts that are not interchangeable. As for spherical aberration, a simple static model with a reference cornea deviating from a Cartesian oval can provide a 2:1 correspondence between corneal and ocular spherical aberration.<\/jats:p>\n          <\/jats:sec>","DOI":"10.3928\/1081597x-20101001-01","type":"journal-article","created":{"date-parts":[[2010,10,18]],"date-time":"2010-10-18T20:04:59Z","timestamp":1287432299000},"page":"434-443","source":"Crossref","is-referenced-by-count":16,"title":["Correlation Among Ocular Spherical Aberration, Corneal Spherical Aberration, and Corneal Asphericity Before and After LASIK for Myopic Astigmatism with the SCHWIND Amaris Platform"],"prefix":"10.3928","volume":"27","author":[{"given":"Samuel Arba","family":"Mosquera","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Diego","family":"de Ortueta","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"2308","reference":[{"key":"e_1_3_2_2_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(02)01895-3"},{"key":"e_1_3_2_3_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2004.01.026"},{"key":"e_1_3_2_4_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2006.01.049"},{"key":"e_1_3_2_5_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081-597X-19930901-08"},{"key":"e_1_3_2_6_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(00)00827-0"},{"key":"e_1_3_2_7_2","doi-asserted-by":"publisher","DOI":"10.1167\/4.4.9"},{"key":"e_1_3_2_8_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081-597X-20030301-04"},{"key":"e_1_3_2_9_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081-597X-20030901-06"},{"key":"e_1_3_2_10_2","doi-asserted-by":"publisher","DOI":"10.1364\/JOSAA.19.002329"},{"issue":"13","key":"e_1_3_2_11_2","first-page":"3349","article-title":"Optical response to LASIK surgery for myopia from total and corneal aberration measurements","volume":"42","author":"Marcos S","year":"2001","unstructured":"Marcos S, Barbero S, Llorente L, Merayo-Lloves J. Optical response to LASIK surgery for myopia from total and corneal aberration measurements. Invest Ophthalmol Vis Sci. 2001;42(13):3349\u20133356.","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"e_1_3_2_12_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081-597X-20010901-19"},{"key":"e_1_3_2_13_2","doi-asserted-by":"publisher","DOI":"10.1167\/6.1.1"},{"key":"e_1_3_2_14_2","doi-asserted-by":"publisher","DOI":"10.1364\/JOSAA.24.003274"},{"key":"e_1_3_2_15_2","doi-asserted-by":"publisher","DOI":"10.1364\/JOSAA.18.001793"},{"key":"e_1_3_2_16_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(03)00467-X"},{"key":"e_1_3_2_17_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081-597X-20020901-30"},{"key":"e_1_3_2_18_2","first-page":"101","volume-title":"Visual Instrumentation: Optical Design & Engineering Principles","author":"Thibos L","year":"1999","unstructured":"Thibos L, Bradley A. Modeling the refractive and neurosensor systems of the eye. In: , Mouroulis P, ed. Visual Instrumentation: Optical Design & Engineering Principles. Columbus, OH: McGraw-Hill Companies; 1999:101\u2013159."},{"key":"e_1_3_2_19_2","doi-asserted-by":"publisher","DOI":"10.1038\/254663a0"},{"key":"e_1_3_2_20_2","doi-asserted-by":"publisher","DOI":"10.1080\/713820960"},{"key":"e_1_3_2_21_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1475-1313.1989.tb00899.x"},{"key":"e_1_3_2_22_2","doi-asserted-by":"publisher","DOI":"10.1097\/00006324-199711000-00021"},{"key":"e_1_3_2_23_2","unstructured":"Salmon TO. Corneal contribution to the wavefront aberration of the eye [PhD dissertation]. Bloomington IN: Indiana University; 1999:70."},{"key":"e_1_3_2_24_2","unstructured":"Snellen H. Letterproeven tot bepaling der gezichtsscherpte. Utrecht The Netherlands: Weyers; 1862."},{"key":"e_1_3_2_25_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00347-008-1717-z"},{"key":"e_1_3_2_26_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(88)80063-4"},{"key":"e_1_3_2_27_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2004.10.046"},{"key":"e_1_3_2_28_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2003.09.008"},{"key":"e_1_3_2_29_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081-597X-20070501-15"},{"key":"e_1_3_2_30_2","doi-asserted-by":"publisher","DOI":"10.1364\/OE.16.003877"},{"key":"e_1_3_2_31_2","doi-asserted-by":"publisher","DOI":"10.1007\/BF02181196"},{"key":"e_1_3_2_32_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(01)01163-4"},{"key":"e_1_3_2_33_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081-597X-20030101-04"},{"key":"e_1_3_2_34_2","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.08-1766"},{"key":"e_1_3_2_35_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081-597X-20050101-08"},{"key":"e_1_3_2_36_2","doi-asserted-by":"publisher","DOI":"10.1093\/mnras\/94.5.377"},{"key":"e_1_3_2_37_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2008.09.014"},{"key":"e_1_3_2_38_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081-597X-20050901-22"},{"key":"e_1_3_2_39_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1475-1313.2006.00461.x"},{"key":"e_1_3_2_40_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20080501-12"},{"key":"e_1_3_2_41_2","doi-asserted-by":"publisher","DOI":"10.1088\/0959-5309\/55\/5\/302"},{"key":"e_1_3_2_42_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1475-1313.2009.00670.x"},{"issue":"4","key":"e_1_3_2_43_2","first-page":"941","article-title":"Analysis of customized corneal ablations: theoretical limitations of increasing negative asphericity","volume":"43","author":"Gatinel D","year":"2002","unstructured":"Gatinel D, Malet J, Hoang-Xuan T, Azar DT. Analysis of customized corneal ablations: theoretical limitations of increasing negative asphericity. Invest Ophthalmol Vis Sci. 2002;43(4):941\u2013948.","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"e_1_3_2_44_2","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.03-0753"},{"key":"e_1_3_2_45_2","doi-asserted-by":"publisher","DOI":"10.1364\/JOSAA.17.000955"},{"key":"e_1_3_2_46_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2004.08.035"},{"key":"e_1_3_2_47_2","volume-title":"Presented at: 6th International Congress on Wavefront Sensing and Optimized Refractive Corrections","author":"Artal P","unstructured":"Artal P. What aberration pattern (if any) produces the best vision? Presented at: 6th International Congress on Wavefront Sensing and Optimized Refractive Corrections; February 11\u201313, 2005; Athens, Greece."},{"key":"e_1_3_2_48_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(01)01322-0"},{"key":"e_1_3_2_49_2","doi-asserted-by":"publisher","DOI":"10.1080\/09500340308235245"},{"key":"e_1_3_2_50_2","doi-asserted-by":"publisher","DOI":"10.3341\/kjo.2008.22.3.164"},{"key":"e_1_3_2_51_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20091016-04"},{"key":"e_1_3_2_52_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081-597X-20040901-32"},{"key":"e_1_3_2_53_2","doi-asserted-by":"publisher","DOI":"10.1097\/01.opx.0000232227.70122.b5"},{"issue":"5","key":"e_1_3_2_54_2","first-page":"S678","article-title":"Correlation of wavefront data and corneal asphericity with contrast sensitivity after laser in situ keratomileusis for myopia","volume":"20","author":"Pop M","year":"2004","unstructured":"Pop M, Payette Y. Correlation of wavefront data and corneal asphericity with contrast sensitivity after laser in situ keratomileusis for myopia. J Refract Surg. 2004;20(5 Suppl):S678\u2013S684.","journal-title":"J Refract Surg"}],"container-title":["Journal of Refractive Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.slackinc.com\/doi\/resolver.asp?doi=10.3928\/1081597X-20101001-01","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,5,3]],"date-time":"2023-05-03T07:20:23Z","timestamp":1683098423000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.healio.com\/doi\/10.3928\/1081597X-20101001-01"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2011,6]]},"references-count":53,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2011,6]]}},"alternative-id":["10.3928\/1081597X-20101001-01"],"URL":"https:\/\/doi.org\/10.3928\/1081597x-20101001-01","relation":{},"ISSN":["1081-597X"],"issn-type":[{"value":"1081-597X","type":"print"}],"subject":[],"published":{"date-parts":[[2011,6]]}}}