{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,25]],"date-time":"2026-09-25T00:51:47Z","timestamp":1790297507265,"version":"4.1.0"},"reference-count":52,"publisher":"SLACK, Inc.","issue":"3","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Refract Surg"],"published-print":{"date-parts":[[2012,3]]},"abstract":"<jats:sec>\n                    <jats:title>PURPOSE:<\/jats:title>\n                    <jats:p>To provide an overview of the clinical results of different ablation profiles based on wavefront technology and discuss their characteristics and limitations.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>METHODS:<\/jats:title>\n                    <jats:p>Literature review of studies reporting results of ablation profiles based on wavefront technology in virgin healthy eyes.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>RESULTS:<\/jats:title>\n                    <jats:p>Over the past 10 years, a large number of studies comparing different treatment algorithms and newer excimer laser platforms have been published. Thirty-six clinical studies including 3637 eyes analyzing the clinical results obtained after wavefront-guided, wavefront-optimized, and Q-factor profiles have been reviewed. Although wavefront-driven profiles allowed reduction of the amount of induced optical aberrations with conventional ablations, thereby improving the quality of vision, it appears that no algorithm of treatment or excimer laser platform has demonstrated a clear superiority over another. Wound healing and unexpected biomechanical response to surgery affect the accuracy of customized treatments and produce variable results. In addition, it is difficult to rigorously analyze and compare findings among different studies because of the diverse variety in which the data are reported.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>CONCLUSIONS:<\/jats:title>\n                    <jats:p>Despite several technological improvements over the years, wavefront ablation profiles have not consistently demonstrated superiority in terms of visual acuity and lower order aberrations compared to the standard procedure, although the induction of higher order aberrations has been reduced. The concept of an individualized eye model has emerged recently, based on the optical ray tracing algorithm, and could theoretically provide a higher level of customization, thus fulfilling the promise of \u201csuper vision.\u201d<\/jats:p>\n                  <\/jats:sec>","DOI":"10.3928\/1081597x-20120217-01","type":"journal-article","created":{"date-parts":[[2012,2,28]],"date-time":"2012-02-28T08:54:54Z","timestamp":1330419294000},"page":"224-232","source":"Crossref","is-referenced-by-count":47,"title":["Wavefront Ablation Profiles in Refractive Surgery: Description, Results, and Limitations"],"prefix":"10.3928","volume":"28","author":[{"given":"David","family":"Smadja","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Glauco","family":"Reggiani-Mello","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marcony R.","family":"Santhiago","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ronald R.","family":"Krueger","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"2308","reference":[{"key":"e_1_3_2_2_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(88)80063-4"},{"key":"e_1_3_2_3_2","doi-asserted-by":"publisher","DOI":"10.1097\/00055735-200308000-00005"},{"key":"e_1_3_2_4_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(01)01163-4"},{"issue":"2","key":"e_1_3_2_5_2","doi-asserted-by":"crossref","first-page":"S186","DOI":"10.3928\/1081-597X-19980401-09","article-title":"A scanning and rotating slit arF excimer laser delivery system for refractive surgery","volume":"14","author":"Lubatschowski H","year":"1998","unstructured":"Lubatschowski H, Kermani O, Welling H, Ertmer W. A scanning and rotating slit arF excimer laser delivery system for refractive surgery. J Refract Surg. 1998;14(2 Suppl):S186\u2013S191.","journal-title":"J Refract Surg"},{"key":"e_1_3_2_6_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081-597X-20051101-25"},{"key":"e_1_3_2_7_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(02)01638-3"},{"key":"e_1_3_2_8_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081-597X-20041101-12"},{"key":"e_1_3_2_9_2","volume-title":"Presented at: 6th International Wavefront Congress","author":"Artal P","unstructured":"Artal P. What aberration pattern (if any) produces the best vision? Presented at: 6th International Wavefront Congress; February 11\u201313, 2005; Athens, Greece."},{"key":"e_1_3_2_10_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2004.01.026"},{"key":"e_1_3_2_11_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(01)01322-0"},{"issue":"5","key":"e_1_3_2_12_2","first-page":"S595","article-title":"Optimized prolate ablations with the NIDEK CXII excimer laser","volume":"21","author":"Holladay JT","year":"2005","unstructured":"Holladay JT, Bains HS. Optimized prolate ablations with the NIDEK CXII excimer laser. J Refract Surg. 2005;21(5 Suppl):S595\u2013S597.","journal-title":"J Refract Surg"},{"key":"e_1_3_2_13_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20100212-04"},{"key":"e_1_3_2_14_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2003.06.022"},{"issue":"13","key":"e_1_3_2_15_2","first-page":"3349","article-title":"Optical response to LASIK surgery for myopia from total and corneal aberration measurements","volume":"42","author":"Marcos S","year":"2001","unstructured":"Marcos S, Barbero S, Llorente L, Merayo-Lloves J. Optical response to LASIK surgery for myopia from total and corneal aberration measurements. Invest Ophthalmol. 2001;42(13):3349\u20133356.","journal-title":"Invest Ophthalmol"},{"issue":"42","key":"e_1_3_2_16_2","first-page":"1396","article-title":"Ocular aberrations before and after myopic corneal refractive surgery: LASIK-induced changes measured with laser ray tracing","author":"Moreno-Barriuso E","year":"2001","unstructured":"Moreno-Barriuso E, Lloves JM, Marcos S, Navarro R, Llorente L, Barbero S. Ocular aberrations before and after myopic corneal refractive surgery: LASIK-induced changes measured with laser ray tracing. Invest Ophthalmol Vis Sci. 2001;(42):1396\u20131403.","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"e_1_3_2_17_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081-597X-20000901-12"},{"key":"e_1_3_2_18_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20101215-08"},{"key":"e_1_3_2_19_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081-597X-20000901-27"},{"key":"e_1_3_2_20_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2005.07.045"},{"key":"e_1_3_2_21_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2008.12.038"},{"key":"e_1_3_2_22_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081-597X-20051101-29"},{"key":"e_1_3_2_23_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2010.12.058"},{"key":"e_1_3_2_24_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2010.12.039"},{"key":"e_1_3_2_25_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2007.06.037"},{"key":"e_1_3_2_26_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081-597X-20070101-06"},{"key":"e_1_3_2_27_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081-597X-20040901-39"},{"key":"e_1_3_2_28_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20100921-07"},{"key":"e_1_3_2_29_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2009.05.035"},{"issue":"5","key":"e_1_3_2_30_2","doi-asserted-by":"crossref","first-page":"S674","DOI":"10.3928\/1081-597X-20040903-08","article-title":"Comparison of conventional and OATz ablation profiles for laser in situ keratomileusis to correct myopia up to \u221210.00 diopters","volume":"20","author":"Vongthongsri A","year":"2004","unstructured":"Vongthongsri A, Phusitphoykai N, Siriboonkoom J. Comparison of conventional and OATz ablation profiles for laser in situ keratomileusis to correct myopia up to \u221210.00 diopters. J Refract Surg. 2004;20(5 Suppl):S674\u2013S675.","journal-title":"J Refract Surg"},{"issue":"2","key":"e_1_3_2_31_2","doi-asserted-by":"crossref","first-page":"S217","DOI":"10.3928\/1081-597X-20030302-08","article-title":"Comparison of conventional versus wavefront-guided laser in situ keratomileusis in the same patient","volume":"19","author":"Phusitphoykai N","year":"2003","unstructured":"Phusitphoykai N, Tungsiripat T, Siriboonkoom J, Vongthongsri A. Comparison of conventional versus wavefront-guided laser in situ keratomileusis in the same patient. J Refract Surg. 2003;19(2 Suppl):S217\u2013S221.","journal-title":"J Refract Surg"},{"key":"e_1_3_2_32_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20081101-07"},{"key":"e_1_3_2_33_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081-597X-20040901-04"},{"key":"e_1_3_2_34_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081-597X-20040901-03"},{"key":"e_1_3_2_35_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081-597X-20060901-05"},{"key":"e_1_3_2_36_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2005.11.026"},{"key":"e_1_3_2_37_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20090401-03"},{"issue":"4","key":"e_1_3_2_38_2","first-page":"S424","article-title":"Wavefront-optimized versus wavefront-guided LASIK for myopic astigmatism with the ALLEGRETTO WAVE: three-month results of a prospective FDA trial","volume":"24","author":"Stonecipher KG","year":"2008","unstructured":"Stonecipher KG, Kezirian GM. Wavefront-optimized versus wavefront-guided LASIK for myopic astigmatism with the ALLEGRETTO WAVE: three-month results of a prospective FDA trial. J Refract Surg. 2008;24(4):S424\u2013S431.","journal-title":"J Refract Surg"},{"key":"e_1_3_2_39_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2007.10.028"},{"key":"e_1_3_2_40_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20090915-04"},{"key":"e_1_3_2_41_2","doi-asserted-by":"publisher","DOI":"10.1097\/OPX.0b013e3182333a50"},{"key":"e_1_3_2_42_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20080501-05"},{"key":"e_1_3_2_43_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2009.09.031"},{"key":"e_1_3_2_44_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2006.01.049"},{"key":"e_1_3_2_45_2","doi-asserted-by":"publisher","DOI":"10.1177\/112067210901900405"},{"key":"e_1_3_2_46_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20081001-03"},{"key":"e_1_3_2_47_2","doi-asserted-by":"publisher","DOI":"10.1097\/01.opx.0000232227.70122.b5"},{"key":"e_1_3_2_48_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ohc.2004.03.002"},{"key":"e_1_3_2_49_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081-597X-20011101-05"},{"key":"e_1_3_2_50_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(03)00334-1"},{"key":"e_1_3_2_51_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20090422-05"},{"issue":"4","key":"e_1_3_2_52_2","first-page":"S446","article-title":"Optical ray tracing for the calculation of optimized corneal ablation profiles in refractive treatment planning","volume":"24","author":"Mrochen M","year":"2008","unstructured":"Mrochen M, Bueeler M, Donitzky C, Seiler T. Optical ray tracing for the calculation of optimized corneal ablation profiles in refractive treatment planning. J Refract Surg. 2008;24(4):S446\u2013S451.","journal-title":"J Refract Surg"},{"key":"e_1_3_2_53_2","volume-title":"Presented at: WaveLight User Meeting","author":"Cummings AB","unstructured":"Cummings AB. Ray tracing profiles for laser refractive surgery - initial results from the European Multicenter Trial. Presented at: WaveLight User Meeting; June 26, 2010; Dublin, Ireland."}],"container-title":["Journal of Refractive Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.slackinc.com\/doi\/resolver.asp?doi=10.3928\/1081597X-20120217-01","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,5,3]],"date-time":"2023-05-03T09:30:50Z","timestamp":1683106250000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.healio.com\/doi\/10.3928\/1081597X-20120217-01"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2012,3]]},"references-count":52,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2012,3]]}},"alternative-id":["10.3928\/1081597X-20120217-01"],"URL":"https:\/\/doi.org\/10.3928\/1081597x-20120217-01","relation":{"has-review":[{"id-type":"doi","id":"10.3410\/f.714147863.789552921","asserted-by":"object"},{"id-type":"doi","id":"10.3410\/f.714147863.791552827","asserted-by":"object"}]},"ISSN":["1081-597X"],"issn-type":[{"value":"1081-597X","type":"print"}],"subject":[],"published":{"date-parts":[[2012,3]]}}}