{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,16]],"date-time":"2026-02-16T18:43:22Z","timestamp":1771267402682,"version":"3.50.1"},"reference-count":31,"publisher":"SLACK, Inc.","issue":"8","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Refract Surg"],"published-print":{"date-parts":[[2012,8]]},"abstract":"<jats:sec>\n            <jats:title>PURPOSE:<\/jats:title>\n            <jats:p>To compare the visual outcomes and wavefront analyses of patients who underwent cataract surgery with the implantation of a Tecnis toric intraocular lens (IOL) (Abbott Medical Optics) with those patients who received an Acrysof IQ toric IOL (Alcon Laboratories Inc).<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>METHODS:<\/jats:title>\n            <jats:p>The study included 40 eyes from 26 patients with regular corneal astigmatism between 1.00 and 3.00 diopters (D) who were undergoing phacoemulsification with implantation of a toric IOL. Patients were randomized into two groups (20 eyes in each group): one group received the Tecnis toric IOL (Tecnis group) and one group received the Acrysof IQ toric IOL (Acrysof group). Over a 2-month follow-up period, the main outcome measures were uncorrected (UDVA) and corrected distance visual acuity (CDVA), spherical equivalent refraction, residual astigmatism, rotational stability of the IOL, and higher order aberrations, measured with a dynamic retinoscopy aberrometer.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>RESULTS:<\/jats:title>\n            <jats:p>\n              At 2-month follow-up, UDVA, CDVA, spherical equivalent refraction, and residual astigmatism showed no statistically significant between-group differences (\n              <jats:italic>P<\/jats:italic>\n              =.834,\n              <jats:italic>P<\/jats:italic>\n              =.178,\n              <jats:italic>P<\/jats:italic>\n              =.447, and\n              <jats:italic>P<\/jats:italic>\n              =.166, respectively). No eye had IOL rotation &gt;10\u00b0. The toric IOL axis misalignment was similar in both groups (3.15\u00b0\u00b12.62\u00b0 in the Tecnis group and 3.25\u00b0\u00b12.04\u00b0 in the Acrysof group,\n              <jats:italic>P<\/jats:italic>\n              =.265). No statistically significant between-group differences were noted for all ocular aberrometry values, except for spherical aberration, which was higher in the Acrysof group (\n              <jats:italic>P<\/jats:italic>\n              =.029).\n            <\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>CONCLUSIONS:<\/jats:title>\n            <jats:p>Both studied IOLs promoted good postoperative UDVA, CDVA, and refractive results. Rotational stability was excellent for both IOLs. Postoperative spherical aberration was higher for the Acrysof toric IOL; however, this difference did not seem to affect overall visual quality.<\/jats:p>\n          <\/jats:sec>","DOI":"10.3928\/1081597x-20120703-03","type":"journal-article","created":{"date-parts":[[2012,7,13]],"date-time":"2012-07-13T07:20:19Z","timestamp":1342164019000},"page":"551-556","source":"Crossref","is-referenced-by-count":48,"title":["Comparison of the Visual Outcomes and OPD-Scan Results of AMO Tecnis Toric and Alcon Acrysof IQ Toric Intraocular Lenses"],"prefix":"10.3928","volume":"28","author":[{"given":"Tiago B.","family":"Ferreira","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ana","family":"Almeida","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"2308","reference":[{"key":"e_1_3_2_2_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2011.04.026"},{"key":"e_1_3_2_3_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2010.02.025"},{"key":"e_1_3_2_4_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2008.09.027"},{"key":"e_1_3_2_5_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20110317-03"},{"key":"e_1_3_2_6_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2004.11.053"},{"key":"e_1_3_2_7_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081-597X-20030701-07"},{"key":"e_1_3_2_8_2","doi-asserted-by":"publisher","DOI":"10.2147\/OPTH.S23345"},{"key":"e_1_3_2_9_2","doi-asserted-by":"publisher","DOI":"10.1097\/ICU.0b013e3283477c9c"},{"key":"e_1_3_2_10_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2008.11.043"},{"key":"e_1_3_2_11_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2010.04.043"},{"key":"e_1_3_2_12_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20100526-01"},{"key":"e_1_3_2_13_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ohc.2004.02.003"},{"key":"e_1_3_2_14_2","unstructured":"Summary of Safety and Effectiveness Data. US Food and Drug Administration Web site. www.accessdata.fda.gov\/cdrh_docs\/pdf\/P930014S015b.pdf. Accessed March 7 2012."},{"key":"e_1_3_2_15_2","unstructured":"Summary of Safety and Effectiveness Data. US Food and Drug Administration Web site. http:\/\/www.accessdata.fda.gov\/cdrh_docs\/pdf\/P930014S045b.pdf. Accessed March 7 2012."},{"key":"e_1_3_2_16_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2007.11.033"},{"key":"e_1_3_2_17_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2011.02.028"},{"key":"e_1_3_2_18_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2011.08.028"},{"key":"e_1_3_2_19_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2010.05.018"},{"key":"e_1_3_2_20_2","doi-asserted-by":"publisher","DOI":"10.5301\/ejo.5000090"},{"key":"e_1_3_2_21_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2009.10.044"},{"key":"e_1_3_2_22_2","volume-title":"Presented at: XXIX Congress of the European Society of Cataract and Refractive Surgeons","author":"Shah S","unstructured":"Shah S, Sheppard A, Bhatt U, Wolffsohn J. Visual outcomes and patient satisfaction with a new toric monofocal intraocular lens. Presented at: XXIX Congress of the European Society of Cataract and Refractive Surgeons; September 17\u201321, 2011; Vienna, Austria."},{"key":"e_1_3_2_23_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2009.08.033"},{"issue":"9","key":"e_1_3_2_24_2","doi-asserted-by":"crossref","first-page":"S1021","DOI":"10.3928\/1081-597X-20061102-02","article-title":"Precision of NIDEK OPD-scan measurements","volume":"22","author":"Holzer MP","year":"2006","unstructured":"Holzer MP, Goebels S, Auffarth GU. Precision of NIDEK OPD-scan measurements. J Refract Surg. 2006;22(9 Suppl):S1021\u2013S1023.","journal-title":"J Refract Surg"},{"key":"e_1_3_2_25_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081-597X-20061101-10"},{"key":"e_1_3_2_26_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2004.11.052"},{"key":"e_1_3_2_27_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2009.03.052"},{"key":"e_1_3_2_28_2","doi-asserted-by":"publisher","DOI":"10.3129\/i08-121"},{"key":"e_1_3_2_29_2","doi-asserted-by":"publisher","DOI":"10.1097\/ICU.0b013e3282f2d791"},{"key":"e_1_3_2_30_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2008.09.017"},{"key":"e_1_3_2_31_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2004.01.005"},{"key":"e_1_3_2_32_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0002-9394(02)01402-2"}],"container-title":["Journal of Refractive Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.healio.com\/doiresolver?doi=10.3928\/1081597X-20120703-03","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,5,3]],"date-time":"2023-05-03T12:27:06Z","timestamp":1683116826000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.healio.com\/doi\/10.3928\/1081597X-20120703-03"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2012,8]]},"references-count":31,"journal-issue":{"issue":"8","published-print":{"date-parts":[[2012,8]]}},"alternative-id":["10.3928\/1081597X-20120703-03"],"URL":"https:\/\/doi.org\/10.3928\/1081597x-20120703-03","relation":{},"ISSN":["1081-597X"],"issn-type":[{"value":"1081-597X","type":"print"}],"subject":[],"published":{"date-parts":[[2012,8]]}}}