{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,8]],"date-time":"2026-09-08T15:34:27Z","timestamp":1788881667212,"version":"build-2803163510"},"reference-count":12,"publisher":"SLACK, Inc.","issue":"2","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Refract Surg"],"published-print":{"date-parts":[[2013,2]]},"abstract":"<jats:sec>\n            <jats:title>PURPOSE:<\/jats:title>\n            <jats:p>To investigate inter-device agreement between the Pentacam (Optikgerate GmbH, Wetzlar, Germany) and IOLMaster (Carl Zeiss Meditec, Jena, Germany) in measuring corneal power, cylinder, and axis of astigmatism.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>METHODS:<\/jats:title>\n            <jats:p>Retrospective case series reviewing the status of eyes after toric IOL implantation to evaluate inter-device agreement in measuring corneal power, cylinder, and axis of astigmatism.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>RESULTS:<\/jats:title>\n            <jats:p>\n              Forty-nine eyes from 41 patients were evaluated. Agreement for corneal power and cylinder were deemed good and moderate, with 95% limits of agreement of \u22121.02 to +1.13 and \u22121.37 to +1.09 diopters (D), respectively. Agreement for axis of astigmatism was only fair, with a mean absolute difference of 8.9 degrees (range: 0.3 to 37.7 degrees, standard deviation: 8.79 degrees). Thirty percent of eyes had a 10-degree or greater difference in axis measurements, and 13% of eyes had a 20-degree or greater difference in measurements. Analysis by multivariate logistic regression showed higher cylinder powers associated with discrepant corneal power measurements (odds ratio: 3.46,\n              <jats:italic>P<\/jats:italic>\n              = .02), and increasing age was associated with discrepant axis measurements (odds ratio: 1.09,\n              <jats:italic>P<\/jats:italic>\n              = .03). Overall, there was no significant difference in accuracy predicting postoperative spherical equivalent refraction.\n            <\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>CONCLUSIONS:<\/jats:title>\n            <jats:p>Pentacam and IOLMaster agree well for corneal power but less so for cylinder and axis of astigmatism and thus cannot be used interchangeably.<\/jats:p>\n          <\/jats:sec>","DOI":"10.3928\/1081597x-20130117-06","type":"journal-article","created":{"date-parts":[[2013,2,4]],"date-time":"2013-02-04T16:31:59Z","timestamp":1359995519000},"page":"114-120","source":"Crossref","is-referenced-by-count":22,"title":["Agreement Between Pentacam and IOLMaster in Patients Undergoing Toric IOL Implantation"],"prefix":"10.3928","volume":"29","author":[{"given":"Bradford W.","family":"Lee","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anat","family":"Galor","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"William J.","family":"Feuer","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bozorgmehr","family":"Pouyeh","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jesse S.","family":"Pelletier","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pravin K.","family":"Vaddavalli","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Benjamin T.","family":"Lemelman","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Craig","family":"See","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sonia H.","family":"Yoo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"2308","reference":[{"key":"e_1_3_2_2_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2005.03.058"},{"key":"e_1_3_2_3_2","doi-asserted-by":"publisher","DOI":"10.1136\/bjo.86.4.458"},{"key":"e_1_3_2_4_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2006.08.031"},{"key":"e_1_3_2_5_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2009.02.031"},{"key":"e_1_3_2_6_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2010.08.050"},{"key":"e_1_3_2_7_2","doi-asserted-by":"publisher","DOI":"10.3129\/i09-172"},{"key":"e_1_3_2_8_2","doi-asserted-by":"publisher","DOI":"10.1191\/096228099673819272"},{"key":"e_1_3_2_9_2","volume-title":"Eye Care: Physician Performance Measurement Set","author":"American Academy of Ophthalmology, Physician Consortium for Performance Improvement, National Committee for Quality Assurance","year":"2010","unstructured":"American Academy of Ophthalmology, Physician Consortium for Performance Improvement, National Committee for Quality Assurance. Eye Care: Physician Performance Measurement Set. Chicago: American Medical Association; 2010."},{"key":"e_1_3_2_10_2","doi-asserted-by":"publisher","DOI":"10.1186\/1471-2415-8-22"},{"key":"e_1_3_2_11_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2011.11.026"},{"key":"e_1_3_2_12_2","doi-asserted-by":"publisher","DOI":"10.1177\/112067210501500102"},{"key":"e_1_3_2_13_2","doi-asserted-by":"publisher","DOI":"10.1001\/archopht.126.7.929"}],"container-title":["Journal of Refractive Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.healio.com\/doiresolver?doi=10.3928\/1081597X-20130117-06","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,5,2]],"date-time":"2023-05-02T22:35:18Z","timestamp":1683066918000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.healio.com\/doi\/10.3928\/1081597X-20130117-06"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2013,2]]},"references-count":12,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2013,2]]}},"alternative-id":["10.3928\/1081597X-20130117-06"],"URL":"https:\/\/doi.org\/10.3928\/1081597x-20130117-06","relation":{},"ISSN":["1081-597X"],"issn-type":[{"value":"1081-597X","type":"print"}],"subject":[],"published":{"date-parts":[[2013,2]]}}}