{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,6]],"date-time":"2025-10-06T19:24:15Z","timestamp":1759778655473},"reference-count":7,"publisher":"SLACK, Inc.","issue":"1","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Refract Surg"],"published-print":{"date-parts":[[2014,1]]},"abstract":"<jats:sec>\n            <jats:title>PURPOSE:<\/jats:title>\n            <jats:p>To increase precision in toric intraocular lens selection by reducing the frequency of outliers that arise from technology-dependent variability during the preoperative assessment for routine cataract surgery.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>METHODS:<\/jats:title>\n            <jats:p>\n              Mean preoperative values for absolute sphere, amount of astigmatism, and steepest cylindrical axis were obtained for 87 eyes (54 patients) each with a manual keratometer and four automated keratometers. The mean sphere, amount of astigmatism, and steepest cylindrical axis across five technologies for each eye were defined as the\n              <jats:italic>meld<\/jats:italic>\n              sphere,\n              <jats:italic>meld<\/jats:italic>\n              astigmatism, and\n              <jats:italic>meld<\/jats:italic>\n              axis, respectively. Each technology was evaluated against the\n              <jats:italic>meld<\/jats:italic>\n              by Bland\u2013Altman analysis, Student\u2019s paired\n              <jats:italic>t<\/jats:italic>\n              test, and correlation coefficients. Further comparison between individual technologies and the\n              <jats:italic>meld<\/jats:italic>\n              quantified the number of outlier measurements each technology produced.\n            <\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>RESULTS:<\/jats:title>\n            <jats:p>\n              The number of outliers between individual keratometers and the\n              <jats:italic>meld<\/jats:italic>\n              differed with specific measurement of sphere, axis, or amount of astigmatism. Although statistical analysis using Bland\u2013Altman plots, correlation coefficients, and paired\n              <jats:italic>t<\/jats:italic>\n              tests suggested insignificant difference from\n              <jats:italic>meld<\/jats:italic>\n              measurements for each parameter, precision-guided analysis presented more clinically significant outliers. The number of outliers can be reduced for sphere (range: 2%\u201346% to 1%\u20136%), astigmatism (range: 6%\u201323% to 0%\u20132%), and axis outliers (range: 15%\u201327% to 3%\u20136%) by averaging measurements from automated and manual keratometers.\n            <\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>CONCLUSIONS:<\/jats:title>\n            <jats:p>Although multiple keratometry technologies produced similar, average measurements, the authors found a disturbing number of outliers that may be overlooked when employing a single technology. Measurement errors can be dramatically reduced by averaging measurements from manual keratometry with any automated technology to make toric lens selection more precise.<\/jats:p>\n            <jats:p>\n              <jats:bold>\n                [\n                <jats:italic>J Refract Surg.<\/jats:italic>\n                2014;30(1):67\u201372.]\n              <\/jats:bold>\n            <\/jats:p>\n          <\/jats:sec>","DOI":"10.3928\/1081597x-20131217-07","type":"journal-article","created":{"date-parts":[[2014,2,18]],"date-time":"2014-02-18T17:05:43Z","timestamp":1392743143000},"page":"67-72","source":"Crossref","is-referenced-by-count":28,"title":["Optimizing Precision in Toric Lens Selection by Combining Keratometry Techniques"],"prefix":"10.3928","volume":"30","author":[{"given":"Andrew W.","family":"Browne","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Robert H.","family":"Osher","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"2308","reference":[{"key":"e_1_3_2_2_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2011.11.043"},{"key":"e_1_3_2_3_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2011.02.024"},{"key":"e_1_3_2_4_2","doi-asserted-by":"publisher","DOI":"10.1186\/1471-2415-12-41"},{"key":"e_1_3_2_5_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2010.07.005"},{"key":"e_1_3_2_6_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2010.08.050"},{"key":"e_1_3_2_7_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2011.03.055"},{"key":"e_1_3_2_8_2","doi-asserted-by":"publisher","DOI":"10.1038\/sj.eye.6702954"}],"container-title":["Journal of Refractive Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.healio.com\/doiresolver?doi=10.3928\/1081597X-20131217-07","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,5,3]],"date-time":"2023-05-03T13:29:38Z","timestamp":1683120578000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.healio.com\/doi\/10.3928\/1081597X-20131217-07"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2014,1]]},"references-count":7,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2014,1]]}},"alternative-id":["10.3928\/1081597X-20131217-07"],"URL":"https:\/\/doi.org\/10.3928\/1081597x-20131217-07","relation":{},"ISSN":["1081-597X"],"issn-type":[{"value":"1081-597X","type":"print"}],"subject":[],"published":{"date-parts":[[2014,1]]}}}