{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,14]],"date-time":"2026-11-14T04:36:55Z","timestamp":1794631015884,"version":"4.9.1"},"reference-count":22,"publisher":"SLACK, Inc.","issue":"6","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Refract Surg"],"published-print":{"date-parts":[[2014,6,1]]},"abstract":"<jats:sec>\n                    <jats:title>PURPOSE:<\/jats:title>\n                    <jats:p>To report a novel method of contact lens-assisted corneal cross-linking (CACXL) in eyes with thin corneas.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>METHODS:<\/jats:title>\n                    <jats:p>\n                      Patients diagnosed as having progressive keratectasia with a minimum corneal thickness less than 400 and greater than 350\n                      <jats:italic toggle=\"yes\">\u03bc<\/jats:italic>\n                      m after epithelial abrasion were included. After epithelial abrasion, the iso-osmolar riboflavin 0.1% in dextran was applied every 3 minutes for 30 minutes. An ultraviolet barrier-free soft contact lens (0.09-mm thickness, 14-mm diameter) soaked in iso-osmolar riboflavin 0.1% for 30 minutes was placed on the cornea. Once the minimum corneal thickness value was confirmed to be greater than 400\n                      <jats:italic toggle=\"yes\">\u03bc<\/jats:italic>\n                      m, the ultraviolet-A irradiance was started along with instillation of iso-osmolar riboflavin 0.1% in the pre-corneal and pre-contact lens region. Intraoperative minimum corneal thickness changes were recorded with ultrasound pachymetry and optical coherence tomography. Postoperative visual acuity, corneal topography (Orbscan; Bausch &amp; Lomb, Rochester, NY), endothelial cell loss (EM-3000; Tomey, Nagoya, Japan), and stromal demarcation line (Visante; Carl Zeiss Meditec, Jena, Germany) were measured.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>RESULTS:<\/jats:title>\n                    <jats:p>\n                      Fourteen eyes underwent the procedure. Mean preoperative minimum corneal thickness after epithelial abrasion was 377.2 \u00b1 14.5\n                      <jats:italic toggle=\"yes\">\u03bc<\/jats:italic>\n                      m (range: 350 to 398\n                      <jats:italic toggle=\"yes\">\u03bc<\/jats:italic>\n                      m). There was a significant difference in minimum functional corneal thickness (Friedman test,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = .000) intraoperatively, before epithelial abrasion, after epithelial abrasion, and with contact lens and riboflavin film. Mean minimum functional corneal thickness after the contact lens was 485.1 \u00b1 15.8\n                      <jats:italic toggle=\"yes\">\u03bc<\/jats:italic>\n                      m (range: 458 to 511\n                      <jats:italic toggle=\"yes\">\u03bc<\/jats:italic>\n                      m). Mean absolute increase in the minimum corneal thickness along with the contact lens and pre-corneal riboflavin film was 107.9 \u00b1 9.4\n                      <jats:italic toggle=\"yes\">\u03bc<\/jats:italic>\n                      m (range: 90 to 124\n                      <jats:italic toggle=\"yes\">\u03bc<\/jats:italic>\n                      m). Mean depth of stromal demarcation line was 252.9 \u00b1 40.8\n                      <jats:italic toggle=\"yes\">\u03bc<\/jats:italic>\n                      m (range: 208 to 360\n                      <jats:italic toggle=\"yes\">\u03bc<\/jats:italic>\n                      m). There was no significant endothelial loss (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = .063) and the corneal topography was stable at the last follow-up (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = .505).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>CONCLUSIONS:<\/jats:title>\n                    <jats:p>\n                      CACXL technique was effective and safe in performing cross-linking in corneas less than 400\n                      <jats:italic toggle=\"yes\">\u03bc<\/jats:italic>\n                      m after epithelial abrasion and appeared effective based on stromal demarcation line depth.\n                    <\/jats:p>\n                    <jats:p>\n                      <jats:bold>\n                        [\n                        <jats:italic toggle=\"yes\">J Refract Surg.<\/jats:italic>\n                        2014;30(6):366\u2013372.]\n                      <\/jats:bold>\n                    <\/jats:p>\n                  <\/jats:sec>","DOI":"10.3928\/1081597x-20140523-01","type":"journal-article","created":{"date-parts":[[2014,6,27]],"date-time":"2014-06-27T16:52:48Z","timestamp":1403887968000},"page":"366-372","source":"Crossref","is-referenced-by-count":139,"title":["Contact Lens-Assisted Collagen Cross-Linking (CACXL): A New Technique for Cross-Linking Thin Corneas"],"prefix":"10.3928","volume":"30","author":[{"given":"Soosan","family":"Jacob","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dhivya Ashok","family":"Kumar","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Amar","family":"Agarwal","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sushanth","family":"Basu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pratheek","family":"Sinha","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ashvin","family":"Agarwal","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"2308","reference":[{"key":"e_1_3_2_2_2","doi-asserted-by":"publisher","DOI":"10.1006\/exer.1997.0410"},{"key":"e_1_3_2_3_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0002-9394(02)02220-1"},{"key":"e_1_3_2_4_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(03)00407-3"},{"key":"e_1_3_2_5_2","doi-asserted-by":"publisher","DOI":"10.1097\/ICO.0b013e3180334f78"},{"key":"e_1_3_2_6_2","doi-asserted-by":"publisher","DOI":"10.1097\/01.icu.0000233954.86723.25"},{"key":"e_1_3_2_7_2","doi-asserted-by":"publisher","DOI":"10.1186\/1471-2415-9-10"},{"key":"e_1_3_2_8_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2008.10.060"},{"key":"e_1_3_2_9_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2011.08.030"},{"key":"e_1_3_2_10_2","doi-asserted-by":"publisher","DOI":"10.1038\/sj.eye.6700751"},{"key":"e_1_3_2_11_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2009.07.044"},{"key":"e_1_3_2_12_2","doi-asserted-by":"publisher","DOI":"10.2147\/OPTH.S37335"},{"key":"e_1_3_2_13_2","doi-asserted-by":"publisher","DOI":"10.1076\/ceyr.17.11.1058.5233"},{"key":"e_1_3_2_14_2","doi-asserted-by":"publisher","DOI":"10.1001\/archopht.126.5.619"},{"key":"e_1_3_2_15_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2013.09.010"},{"key":"e_1_3_2_16_2","doi-asserted-by":"publisher","DOI":"10.1097\/ICO.0b013e31828733ea"},{"key":"e_1_3_2_17_2","doi-asserted-by":"publisher","DOI":"10.1097\/01.ico.0000225720.38748.58"},{"key":"e_1_3_2_18_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2009.06.031"},{"key":"e_1_3_2_19_2","doi-asserted-by":"publisher","DOI":"10.1097\/ICO.0b013e318030df5a"},{"key":"e_1_3_2_20_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2009.01.009"},{"key":"e_1_3_2_21_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2008.09.048"},{"key":"e_1_3_2_22_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1600-0420.2004.00369.x"},{"key":"e_1_3_2_23_2","first-page":"2165","article-title":"UV absorbance of the human cornea in the 240- to 400-nm range","volume":"43","author":"Kolozsvari L","year":"2002","unstructured":"Kolozsvari L, Nogradi A, Hopp B, Bor Z. UV absorbance of the human cornea in the 240- to 400-nm range. Invest Ophthalmol Vis Sci. 2002;43:2165\u20132168","journal-title":"Invest Ophthalmol Vis Sci"}],"container-title":["Journal of Refractive Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.healio.com\/doiresolver?doi=10.3928\/1081597X-20140523-01","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,7,29]],"date-time":"2026-07-29T15:41:42Z","timestamp":1785339702000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.healio.com\/doi\/10.3928\/1081597X-20140523-01"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2014,6,1]]},"references-count":22,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2014,6,1]]}},"alternative-id":["10.3928\/1081597X-20140523-01"],"URL":"https:\/\/doi.org\/10.3928\/1081597x-20140523-01","relation":{},"ISSN":["1081-597X"],"issn-type":[{"value":"1081-597X","type":"print"}],"subject":[],"published":{"date-parts":[[2014,6,1]]}}}