{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,30]],"date-time":"2026-07-30T06:26:26Z","timestamp":1785392786884,"version":"3.55.0"},"reference-count":80,"publisher":"SLACK, Inc.","issue":"11","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Refract Surg"],"published-print":{"date-parts":[[2014,11]]},"abstract":"<jats:sec>\n            <jats:title>PURPOSE:<\/jats:title>\n            <jats:p>To review the published literature describing the use of the LenSx femtosecond laser technology (Alcon Laboratories, Inc., Fort Worth, TX) in cataract surgery.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>METHODS:<\/jats:title>\n            <jats:p>Literature review.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>RESULTS:<\/jats:title>\n            <jats:p>The LenSx system has been used in more than 200,000 cataract surgery procedures to date. Pre-clinical evaluations have shown that this system produces accurate and reproducible capsulorhexes, and that both the energy required for phacoemulsification and total phacoemulsification time are less than with conventional phacoemulsification. In comparative studies, femtosecond lasers have been shown to produce more precise and reproducible capsulorhexes than manual procedures, and better intraocular lens placement; capsule overlap, circularity of capsulotomy, and centration of the intraocular lens are consistently better with femtosecond lasers than with manual procedures. The improved quality of capsulorhexis and intraocular lens positioning are reflected in favorable visual and refractive outcomes. As with any new technology, there is a significant learning curve: prospective cohort studies have shown that the incidence of intraoperative complications such as suction breaks or anterior capsular tears or tags decreases with experience. In general, the incidence of such complications is within the range (&lt; 2%) considered in recent evidence-based guidelines to be feasible and desirable.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>CONCLUSIONS:<\/jats:title>\n            <jats:p>Although femtosecond laser cataract surgery is in its infancy, the technology is evolving rapidly and offers the potential for more consistent and predictable results after cataract surgery.<\/jats:p>\n            <jats:p>\n              <jats:bold>\n                [\n                <jats:italic>J Refract Surg<\/jats:italic>\n                . 2014;30(11):730\u2013740.]\n              <\/jats:bold>\n            <\/jats:p>\n          <\/jats:sec>","DOI":"10.3928\/1081597x-20141021-04","type":"journal-article","created":{"date-parts":[[2014,11,6]],"date-time":"2014-11-06T15:56:34Z","timestamp":1415289394000},"page":"730-740","source":"Crossref","is-referenced-by-count":30,"title":["The Use of Femtosecond Lasers in Cataract Surgery: Review of the Published Results With the LenSx System"],"prefix":"10.3928","volume":"30","author":[{"given":"Zoltan Z.","family":"Nagy","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Leonardo","family":"Mastropasqua","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michael C.","family":"Knorz","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"2308","reference":[{"key":"e_1_3_3_2_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1442-9071.2012.02851.x"},{"key":"e_1_3_3_3_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20110708-01"},{"key":"e_1_3_3_4_2","doi-asserted-by":"publisher","DOI":"10.1126\/scitranslmed.3001305"},{"key":"e_1_3_3_5_2","doi-asserted-by":"publisher","DOI":"10.3126\/nepjoph.v3i1.4281"},{"key":"e_1_3_3_6_2","doi-asserted-by":"publisher","DOI":"10.17925\/USOR.2013.06.01.38"},{"key":"e_1_3_3_7_2","doi-asserted-by":"publisher","DOI":"10.1097\/ICU.0b013e3283414f76"},{"key":"e_1_3_3_8_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20081101-24"},{"key":"e_1_3_3_9_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2010.03.027"},{"key":"e_1_3_3_10_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20091117-04"},{"key":"e_1_3_3_11_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2005.12.144"},{"key":"e_1_3_3_12_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2013.06.016"},{"key":"e_1_3_3_13_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(01)00908-7"},{"key":"e_1_3_3_14_2","doi-asserted-by":"publisher","DOI":"10.1001\/archopht.126.6.816"},{"key":"e_1_3_3_15_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2008.02.013"},{"key":"e_1_3_3_16_2","volume-title":"Presented at the XXIX Congress of the European Society of Cataract and Refractive Surgeons","author":"Knorz M","unstructured":"Knorz M, Nagy Z. Reduction in mean cumulative dissipated energy (CDE) following lens fragmentation with an intraocular femtosecond laser. Presented at the XXIX Congress of the European Society of Cataract and Refractive Surgeons, Vienna, Austria, September 17\u201321, 2011."},{"key":"e_1_3_3_17_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20110607-01"},{"key":"e_1_3_3_18_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20110623-03"},{"key":"e_1_3_3_19_2","volume-title":"Presented at the XXIX Congress of the European Society of Cataract and Refractive Surgeons","author":"Brint S","unstructured":"Brint S. Comparison of femtosecond and manual capsulorrhexis on refractive predictability in cataract surgery. Presented at the XXIX Congress of the European Society of Cataract and Refractive Surgeons, Vienna, Austria, September 17\u201321, 2011."},{"key":"e_1_3_3_20_2","volume-title":"Presented at the XXIX Congress of the European Society of Cataract and Refractive Surgeons","author":"Donnenfeld E","unstructured":"Donnenfeld E, Slade S. Femtosecond laser created astigmatic incisions in cataract surgery with premium lens implantation. Presented at the XXIX Congress of the European Society of Cataract and Refractive Surgeons, Vienna, Austria, September 17\u201321, 2011."},{"key":"e_1_3_3_21_2","volume-title":"Presented at the XXIX Congress of the European Society of Cataract and Refractive Surgeons","author":"Stonecipher K","unstructured":"Stonecipher K. Comparison of outcomes following toric IOL implantation in cataract surgery: femtosecond laser vs manual capsulotomy. Presented at the XXIX Congress of the European Society of Cataract and Refractive Surgeons, Vienna, Austria, September 17\u201321, 2011."},{"key":"e_1_3_3_22_2","volume-title":"Presented at the American Society of Cataract and Refractive Surgeons meeting","author":"Steinert RF","unstructured":"Steinert RF, Slade SG. Application of femtosecond lasers in cataract surgery for creation of multi-planar self-sealing corneal incisions. Presented at the American Society of Cataract and Refractive Surgeons meeting, San Diego, CA, March 25\u201329, 2011."},{"key":"e_1_3_3_23_2","volume-title":"Presented at the American Society of Cataract and Refractive Surgeons meeting","author":"Slade SG","unstructured":"Slade SG. Comparison of effective lens position: femtosecond laser versus manual capsulotomy. Presented at the American Society of Cataract and Refractive Surgeons meeting, San Diego, CA, March 25\u201329, 2011."},{"key":"e_1_3_3_24_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20130117-05"},{"key":"e_1_3_3_25_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20101223-01"},{"key":"e_1_3_3_26_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1475-1313.2005.00314.x"},{"key":"e_1_3_3_27_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2005.04.026"},{"key":"e_1_3_3_28_2","first-page":"77","article-title":"Centration and diffractive multifocal IOLs","author":"Holladay JT","year":"2010","unstructured":"Holladay JT. Centration and diffractive multifocal IOLs. J Cataract Refract Surg Today. 2010:77\u201378.","journal-title":"J Cataract Refract Surg Today"},{"key":"e_1_3_3_29_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0161-6420(01)00756-4"},{"key":"e_1_3_3_30_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2008.05.046"},{"key":"e_1_3_3_31_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081-597X-20021101-04"},{"key":"e_1_3_3_32_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(99)00204-7"},{"key":"e_1_3_3_33_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20120815-04"},{"key":"e_1_3_3_34_2","volume-title":"Presented at the American Society of Cataract and Refractive Surgeons meeting","author":"Cionni RJ","unstructured":"Cionni RJ. Comparison of effective lens position and refractive outcome in monofocal and multifocal IOLs: femtosecond laser versus manual capsulotomy. Presented at the American Society of Cataract and Refractive Surgeons meeting, Chicago, IL, April 20\u201324, 2012."},{"key":"e_1_3_3_35_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20120309-01"},{"key":"e_1_3_3_36_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20120703-04"},{"key":"e_1_3_3_37_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20110913-01"},{"key":"e_1_3_3_38_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2006.01.099"},{"key":"e_1_3_3_39_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2004.02.072"},{"key":"e_1_3_3_40_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(99)80019-4"},{"key":"e_1_3_3_41_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2011.12.025"},{"key":"e_1_3_3_42_2","doi-asserted-by":"publisher","DOI":"10.1097\/APO.0b013e31823ff9de"},{"key":"e_1_3_3_43_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2011.09.003"},{"key":"e_1_3_3_44_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2012.10.026"},{"key":"e_1_3_3_45_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2006.05.013"},{"key":"e_1_3_3_46_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(98)80235-6"},{"key":"e_1_3_3_47_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2013.08.046"},{"key":"e_1_3_3_48_2","doi-asserted-by":"publisher","DOI":"10.1076\/soph.17.3.110.14783"},{"key":"e_1_3_3_49_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2010.11.001"},{"key":"e_1_3_3_50_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20120508-02"},{"key":"e_1_3_3_51_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2007.02.035"},{"key":"e_1_3_3_52_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2008.12.017"},{"key":"e_1_3_3_53_2","doi-asserted-by":"publisher","DOI":"10.1097\/ICO.0b013e3181583115"},{"key":"e_1_3_3_54_2","doi-asserted-by":"publisher","DOI":"10.3341\/kjo.2010.24.1.10"},{"key":"e_1_3_3_55_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2007.07.033"},{"key":"e_1_3_3_56_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0161-6420(03)00733-4"},{"key":"e_1_3_3_57_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2010.06.058"},{"key":"e_1_3_3_58_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2006.11.012"},{"key":"e_1_3_3_59_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2012.11.018"},{"key":"e_1_3_3_60_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20131217-03"},{"key":"e_1_3_3_61_2","first-page":"557","article-title":"The incidence, pathogenesis and treatment of cystoid macular edema following cataract surgery","volume":"96","author":"Flach AJ","year":"1998","unstructured":"Flach AJ. The incidence, pathogenesis and treatment of cystoid macular edema following cataract surgery. Trans Am Ophthalmol Soc. 1998;96:557\u2013634.","journal-title":"Trans Am Ophthalmol Soc"},{"key":"e_1_3_3_62_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0039-6257(02)00294-1"},{"key":"e_1_3_3_63_2","doi-asserted-by":"publisher","DOI":"10.1159\/000073070"},{"key":"e_1_3_3_64_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(03)00582-0"},{"key":"e_1_3_3_65_2","doi-asserted-by":"publisher","DOI":"10.1038\/sj.eye.6702460"},{"key":"e_1_3_3_66_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1755-3768.2010.01896.x"},{"key":"e_1_3_3_67_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00417-007-0605-6"},{"key":"e_1_3_3_68_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20110825-01"},{"key":"e_1_3_3_69_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2012.02.031"},{"key":"e_1_3_3_70_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2008.09.027"},{"key":"e_1_3_3_71_2","first-page":"333","article-title":"Visual performance in cataract patients with low levels of postoperative astigmatism: full correction versus spherical equivalent correction","volume":"6","author":"Lehmann RP","year":"2012","unstructured":"Lehmann RP, Houtman DM. Visual performance in cataract patients with low levels of postoperative astigmatism: full correction versus spherical equivalent correction. Clin Ophthalmol. 2012;6:333\u2013338.","journal-title":"Clin Ophthalmol"},{"key":"e_1_3_3_72_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20090101-04"},{"key":"e_1_3_3_73_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2009.04.037"},{"key":"e_1_3_3_74_2","volume-title":"Presented at the Annual Congress of the American Academy of Ophthalmology","author":"Lawless MA","unstructured":"Lawless MA. Toric IOL implantation with the femtosecond laser. Presented at the Annual Congress of the American Academy of Ophthalmology, Orlando, FL, October 22\u201325, 2011."},{"key":"e_1_3_3_75_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20120120-01"},{"key":"e_1_3_3_76_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2012.03.006"},{"key":"e_1_3_3_77_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2006.02.063"},{"key":"e_1_3_3_78_2","doi-asserted-by":"publisher","DOI":"10.1038\/sj.eye.6703015"},{"key":"e_1_3_3_79_2","doi-asserted-by":"publisher","DOI":"10.1136\/bjo.2006.104216"},{"key":"e_1_3_3_80_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2004.10.052"},{"key":"e_1_3_3_81_2","doi-asserted-by":"publisher","DOI":"10.1007\/s10792-008-9214-6"}],"container-title":["Journal of Refractive Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.healio.com\/doiresolver?doi=10.3928\/1081597X-20141021-04","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,5,3]],"date-time":"2023-05-03T10:12:58Z","timestamp":1683108778000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.healio.com\/doi\/10.3928\/1081597X-20141021-04"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2014,11]]},"references-count":80,"journal-issue":{"issue":"11","published-print":{"date-parts":[[2014,11]]}},"alternative-id":["10.3928\/1081597X-20141021-04"],"URL":"https:\/\/doi.org\/10.3928\/1081597x-20141021-04","relation":{},"ISSN":["1081-597X"],"issn-type":[{"value":"1081-597X","type":"print"}],"subject":[],"published":{"date-parts":[[2014,11]]}}}