{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,10]],"date-time":"2026-02-10T18:44:43Z","timestamp":1770749083806,"version":"3.50.0"},"reference-count":18,"publisher":"SLACK, Inc.","issue":"12","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Refract Surg"],"published-print":{"date-parts":[[2014,12]]},"abstract":"<jats:sec>\n            <jats:title>PURPOSE:<\/jats:title>\n            <jats:p>To evaluate the rotational stability of a new one-piece hydrophobic acrylic toric intraocular lens (IOL) using a custom-developed software for analysis of slit-lamp photographs.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>METHODS:<\/jats:title>\n            <jats:p>In a prospective, multicenter study, 174 eyes were implanted with the TECNIS Toric IOL (Abbott Medical Optics, Inc., Santa Ana, CA). A custom-developed software was used to analyze high-resolution slit-lamp photographs of 156 eyes taken at day 1 (baseline) and 1, 3, and 6 months postoperatively. The software uses iris and sclera landmarks to align the baseline image and later images for comparison. Validation of software was performed through repeated analyses of protractor images rotated from 0.1\u00b0 to 10.0\u00b0 and randomly selected photographs of 20 eyes.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>RESULTS:<\/jats:title>\n            <jats:p>Software validation showed precision (repeatability plus reproducibility variation) of 0.02\u00b0 using protractor images and 2.22\u00b0 using slit-lamp photographs. Good quality slit-lamp images and clear landmarks were necessary for precise measurements. At 6 months, 94.2% of eyes had 5\u00b0 or less change in IOL orientation versus baseline; only 2 eyes (1.4%) had axis shift greater than 30\u00b0. Most eyes were within 5\u00b0 or less of rotation between 1 and 3 months (92.9%) and 3 and 6 months (94.1%). Mean absolute axis change (\u00b1 standard deviation) from 1 day to 6 months was 2.70\u00b0 \u00b1 5.51\u00b0.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>CONCLUSIONS:<\/jats:title>\n            <jats:p>The new custom software was precise and quick in analyzing slit-lamp photographs to determine postoperative toric IOL rotation.<\/jats:p>\n            <jats:p>\n              <jats:bold>\n                [\n                <jats:italic>J Refract Surg<\/jats:italic>\n                . 2014;30(12):820\u2013826.]\n              <\/jats:bold>\n            <\/jats:p>\n          <\/jats:sec>","DOI":"10.3928\/1081597x-20141117-01","type":"journal-article","created":{"date-parts":[[2014,12,1]],"date-time":"2014-12-01T16:35:45Z","timestamp":1417451745000},"page":"820-826","source":"Crossref","is-referenced-by-count":23,"title":["Software-Based Evaluation of Toric IOL Orientation in a Multicenter Clinical Study"],"prefix":"10.3928","volume":"30","author":[{"given":"Sanjeev","family":"Kasthurirangan","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Lucas","family":"Feuchter","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Pamela","family":"Smith","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Donald","family":"Nixon","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"2308","reference":[{"key":"e_1_3_3_2_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2012.08.055"},{"key":"e_1_3_3_3_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2008.10.057"},{"key":"e_1_3_3_4_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(13)80232-5"},{"key":"e_1_3_3_5_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2011.08.028"},{"key":"e_1_3_3_6_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2010.08.049"},{"key":"e_1_3_3_7_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2009.03.037"},{"key":"e_1_3_3_8_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0161-6420(99)90504-3"},{"key":"e_1_3_3_9_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2008.07.012"},{"key":"e_1_3_3_10_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(02)01843-6"},{"key":"e_1_3_3_11_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(01)01035-5"},{"key":"e_1_3_3_12_2","doi-asserted-by":"publisher","DOI":"10.1038\/eye.2001.61"},{"key":"e_1_3_3_13_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(00)00317-5"},{"key":"e_1_3_3_14_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0161-6420(00)00266-9"},{"key":"e_1_3_3_15_2","unstructured":"U.S. Food and Drug Administration. Premarket approval: Staar elastic ultraviolet-absorbing silicone posterior chamber intraocular lens with toric optic models AA-4203T and AA-4203TF-P880091\/S14. Summary of Safety and Effectiveness Data. November 4 1998."},{"key":"e_1_3_3_16_2","doi-asserted-by":"publisher","DOI":"10.3129\/i09-048"},{"key":"e_1_3_3_17_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2009.02.035"},{"key":"e_1_3_3_18_2","unstructured":"U.S. Food and Drug Administration. Acrysof single-piece posterior chamber intraocular lenses with toric optic. Summary of Safety and Effectiveness Data Report No. P930014\/S015. 2005."},{"key":"e_1_3_3_19_2","unstructured":"U.S. Food and Drug Administration. AcrySof toric intraocular lens models SN60T6 SN60T7 SN60T8 and SN60T9; and AcrySof IQ toric intraocular lens models SN6AT6 SN6AT7 SN6AT8 and SN6AT9. Summary of Safety and Effectiveness Data Report No. P930014\/S025. 2011."}],"container-title":["Journal of Refractive Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.healio.com\/doiresolver?doi=10.3928\/1081597X-20141117-01","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,5,3]],"date-time":"2023-05-03T03:40:49Z","timestamp":1683085249000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.healio.com\/doi\/10.3928\/1081597X-20141117-01"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2014,12]]},"references-count":18,"journal-issue":{"issue":"12","published-print":{"date-parts":[[2014,12]]}},"alternative-id":["10.3928\/1081597X-20141117-01"],"URL":"https:\/\/doi.org\/10.3928\/1081597x-20141117-01","relation":{},"ISSN":["1081-597X"],"issn-type":[{"value":"1081-597X","type":"print"}],"subject":[],"published":{"date-parts":[[2014,12]]}}}