{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,8,31]],"date-time":"2025-08-31T10:01:18Z","timestamp":1756634478573},"reference-count":27,"publisher":"SLACK, Inc.","issue":"3","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Refract Surg"],"published-print":{"date-parts":[[2015,3]]},"abstract":"<jats:sec>\n            <jats:title>PURPOSE:<\/jats:title>\n            <jats:p>To objectively define the effective centration of myopic femtosecond laser-assisted LASIK ablation pattern, evaluate the difference between achieved versus planned excimer laser ablation centration, and compare these results from two different generations of an excimer laser system.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>METHODS:<\/jats:title>\n            <jats:p>The study retrospectively evaluated 280 eyes subjected to myopic LASIK. Digital image analysis was performed on Scheimpflug sagittal curvature maps (difference of preoperative to postoperative). Centration was assessed via proprietary software digital analysis of the coordinate displacement between the achieved ablation geometric center and the planned ablation center, which was the corneal vertex. Results from two different excimer laser generations (Eye-Q 400 [140 eyes] and EX500 [140 eyes]; Alcon\/WaveLight, Fort Worth, TX) were compared.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>RESULTS:<\/jats:title>\n            <jats:p>\n              Radial displacement was on average 360 \u00b1 220\n              <jats:italic>\u00b5<\/jats:italic>\n              m (range: 0 to 1,030\n              <jats:italic>\u00b5<\/jats:italic>\n              m) in the Eye-Q 400 laser group and 120 \u00b1 110\n              <jats:italic>\u00b5<\/jats:italic>\n              m (range: 0 to 580\n              <jats:italic>\u00b5<\/jats:italic>\n              m) in the EX500 laser group (\n              <jats:italic>P<\/jats:italic>\n              &lt; .01). The percentage of eyes with displacement of greater than 300\n              <jats:italic>\u00b5<\/jats:italic>\n              m was 52% in the Eye-Q 400 laser group and 4% in the EX500 laser group.\n            <\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>CONCLUSIONS:<\/jats:title>\n            <jats:p>Displacement of ablation pattern may depend on the laser platform used. The improvement in the efficiency of centration indicates that newer generation excimer lasers with faster eye tracking and active centration control appear to achieve a significantly more accurate centration of myopic ablation patterns. The authors propose this novel, objective technique for laser refractive surgeon evaluation may point out significant outcome measures not currently used in standard metrics of refractive laser efficiency.<\/jats:p>\n            <jats:p>\n              <jats:bold>\n                [\n                <jats:italic>J Refract Surg.<\/jats:italic>\n                2015;31(3):164\u2013169.]\n              <\/jats:bold>\n            <\/jats:p>\n          <\/jats:sec>","DOI":"10.3928\/1081597x-20150225-01","type":"journal-article","created":{"date-parts":[[2015,3,9]],"date-time":"2015-03-09T18:48:27Z","timestamp":1425926907000},"page":"164-169","source":"Crossref","is-referenced-by-count":21,"title":["LASIK Ablation Centration: An Objective Digitized Assessment and Comparison Between Two Generations of an Excimer Laser"],"prefix":"10.3928","volume":"31","author":[{"given":"Anastasios John","family":"Kanellopoulos","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"George","family":"Asimellis","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"2308","reference":[{"key":"e_1_3_2_2_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2008.12.037"},{"issue":"1","key":"e_1_3_2_3_2","first-page":"CD005135","article-title":"Laser-assisted in-situ keratomileusis (LASIK) versus photorefractive keratectomy (PRK) for myopia","author":"Shortt AJ","year":"2013","unstructured":"Shortt AJ, Allan BD, Evans JR. Laser-assisted in-situ keratomileusis (LASIK) versus photorefractive keratectomy (PRK) for myopia. Cochrane Database Syst Rev. 2013;1:CD005135","journal-title":"Cochrane Database Syst Rev"},{"key":"e_1_3_2_4_2","article-title":"Initial clinical experience with the Wavelight ALLEGRETTO-WAVE excimer laser in 287 consecutive myopic eyes treated With LASIK","volume":"43","author":"Stein JJ","year":"2002","unstructured":"Stein JJ, Miller AI, Pettinelli DJ, Kanellopoulos AJ. Initial clinical experience with the Wavelight ALLEGRETTO-WAVE excimer laser in 287 consecutive myopic eyes treated With LASIK. Invest Ophthalmol Vis Sci. 2002;43:E-Abstract 2034.","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"e_1_3_2_5_2","article-title":"Comparison of pre- and post-LASIK high order aberrations and coma with the Wavelight ALLEGRETTO-WAVE laser in non wavefront-guided procedures and measured by the Wavelight ALLEGRETTO aberrometer in 85 consecutive eyes","volume":"43","author":"Pettinelli DJ","year":"2002","unstructured":"Pettinelli DJ, Miller AI, Stein JJ, Kanellopoulos AJ. Comparison of pre- and post-LASIK high order aberrations and coma with the Wavelight ALLEGRETTO-WAVE laser in non wavefront-guided procedures and measured by the Wavelight ALLEGRETTO aberrometer in 85 consecutive eyes. Invest Ophthalmol Vis Sci. 2002;43:E-Abstract 2040.","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"e_1_3_2_6_2","article-title":"Comparison of the Wavelight ALLEGRETTO-WAVE aberrometer to subjective refraction data in pre-operative evaluation of LASIK candidates","volume":"43","author":"Tai A","year":"2002","unstructured":"Tai A, Stein J, Miller A, Pettinelli D, Kanellopoulos AJ. Comparison of the Wavelight ALLEGRETTO-WAVE aberrometer to subjective refraction data in pre-operative evaluation of LASIK candidates. Invest Ophthalmol Vis Sci. 2002;43:E-Abstract 2062.","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"e_1_3_2_7_2","article-title":"Prospective Evaluation of wavefront-guided LASIK with the Allegretto-Wave and the M2 in 150 eyes","volume":"44","author":"Cheng CJ","year":"2003","unstructured":"Cheng CJ, Huang JJ, Kanellopoulos AJ. A Prospective Evaluation of wavefront-guided LASIK with the Allegretto-Wave and the M2 in 150 eyes. Invest Ophthalmol Vis Sci. 2003;44:E-Abstract 2603.","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"e_1_3_2_8_2","article-title":"A prospective evaluation of asphericity-adjusted LASIK with the Allegretto-Wave and the M2 in 105 eyes","volume":"46","author":"Shein J","year":"2005","unstructured":"Shein J, Kanellopoulos AJ, Pe L, Jankov M. A prospective evaluation of asphericity-adjusted LASIK with the Allegretto-Wave and the M2 in 105 eyes. Invest Ophthalmol Vis Sci. 2005;46:E-Abstract 4379.","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"e_1_3_2_9_2","article-title":"A prospective evaluation of asphericity adjusted LASIK with the Allegretto-Wave and the M2 in 645 eyes","volume":"47","author":"Roe RH","year":"2006","unstructured":"Roe RH, Kanellopoulos A, Papakostas A, Pe L, Sperber L, Jankov M. A prospective evaluation of asphericity adjusted LASIK with the Allegretto-Wave and the M2 in 645 eyes. Invest Ophthalmol Vis Sci. 2006;47:E-Abstract 3604","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"e_1_3_2_10_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20090915-06"},{"key":"e_1_3_2_11_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.optom.2011.11.002"},{"key":"e_1_3_2_12_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(00)00884-1"},{"key":"e_1_3_2_13_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081-597X-20050101-08"},{"key":"e_1_3_2_14_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(99)00328-4"},{"key":"e_1_3_2_15_2","doi-asserted-by":"publisher","DOI":"10.1037\/h0043475"},{"key":"e_1_3_2_16_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2008.12.022"},{"key":"e_1_3_2_17_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(00)00806-3"},{"key":"e_1_3_2_18_2","doi-asserted-by":"publisher","DOI":"10.1364\/OE.18.022418"},{"key":"e_1_3_2_19_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2014.02.023"},{"key":"e_1_3_2_20_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2013.03.020"},{"key":"e_1_3_2_21_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20091209-01"},{"key":"e_1_3_2_22_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2007.09.013"},{"key":"e_1_3_2_23_2","doi-asserted-by":"publisher","DOI":"10.2147\/OPTH.S53718"},{"key":"e_1_3_2_24_2","doi-asserted-by":"publisher","DOI":"10.1097\/ICO.0b013e31819ba450"},{"key":"e_1_3_2_25_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20121005-05"},{"key":"e_1_3_2_26_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081-597X-20070501-06"},{"key":"e_1_3_2_27_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081-597X-20060401-08"},{"key":"e_1_3_2_28_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20111115-01"}],"container-title":["Journal of Refractive Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.healio.com\/doiresolver?doi=10.3928\/1081597X-20150225-01","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,5,2]],"date-time":"2023-05-02T21:54:06Z","timestamp":1683064446000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.healio.com\/doi\/10.3928\/1081597X-20150225-01"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2015,3]]},"references-count":27,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2015,3]]}},"alternative-id":["10.3928\/1081597X-20150225-01"],"URL":"https:\/\/doi.org\/10.3928\/1081597x-20150225-01","relation":{},"ISSN":["1081-597X"],"issn-type":[{"value":"1081-597X","type":"print"}],"subject":[],"published":{"date-parts":[[2015,3]]}}}