{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,29]],"date-time":"2026-06-29T10:48:42Z","timestamp":1782730122655,"version":"3.54.5"},"reference-count":26,"publisher":"SLACK, Inc.","issue":"3","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Refract Surg"],"published-print":{"date-parts":[[2015,3]]},"abstract":"<jats:sec>\n            <jats:title>PURPOSE:<\/jats:title>\n            <jats:p>To determine glare-induced change during visual acuity testing in patients with and without cataract using the controlled point source light-emitting diode (LED) glare tester (EpiGlare Tester; Epico, LLC, Columbus, OH), a new medical device for identification of glare disability.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>METHODS:<\/jats:title>\n            <jats:p>This prospective, multicenter study enrolled 40 patients (80 eyes with cataracts) and 49 control subjects (98 eyes without cataracts). Corrected distance visual acuity (CDVA) was measured with and without glare using the EpiGlare Tester as a glare source. Functional visual ability was evaluated using driving and glare subscales from the Refractive Status Vision Profile questionnaire. The primary efficacy measure was change in CDVA measurement with and without glare in patients with senile cataract compared to participants without cataract. Secondary efficacy measures included correlation of the CDVA change caused by functional glare disability and subjective patient and investigator assessments.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>RESULTS:<\/jats:title>\n            <jats:p>\n              CDVA reduction was greater for patients with cataract, with a mean reduction of \u22120.49 \u00b1 0.3 logMAR, than for participants without cataracts at \u22120.13 \u00b1 0.2 logMAR (\n              <jats:italic>P<\/jats:italic>\n              &lt; .001). This equates to a 5-line Snellen reduction (0.49 logMAR) in patients with cataracts and a 1-line reduction (\u22120.13 logMAR) in patients without cataracts. Among patients with cataracts, 83% stated the device accurately represented the difficulty experienced while driving at night (\n              <jats:italic>P<\/jats:italic>\n              &lt; .001); among participants without cataracts, 71% reported being minimally affected by glare from the device (\n              <jats:italic>P<\/jats:italic>\n              = .003).\n            <\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>CONCLUSIONS:<\/jats:title>\n            <jats:p>A new controlled point source LED glare tester demonstrated the adverse effect on visual acuity due to glare in patients with cataract, accurately simulated night driving glare issues for patients with cataracts, and was rated as easy to use and useful by investigators.<\/jats:p>\n            <jats:p>\n              <jats:bold>\n                [\n                <jats:italic>J Refract Surg.<\/jats:italic>\n                2015;31(3):196\u2013201.]\n              <\/jats:bold>\n            <\/jats:p>\n          <\/jats:sec>","DOI":"10.3928\/1081597x-20150225-03","type":"journal-article","created":{"date-parts":[[2015,3,9]],"date-time":"2015-03-09T18:48:21Z","timestamp":1425926901000},"page":"196-201","source":"Crossref","is-referenced-by-count":7,"title":["Evaluation of a New Controlled Point Source LED Glare Tester for Disability Glare Detection in Participants With and Without Cataracts"],"prefix":"10.3928","volume":"31","author":[{"given":"Alice T.","family":"Epitropoulos","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nicole R.","family":"Fram","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Samuel","family":"Masket","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"suffix":"Jr.","given":"Francis W.","family":"Price","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michael E.","family":"Snyder","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"R. Doyle","family":"Stulting","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"2308","reference":[{"key":"e_1_3_3_2_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0161-6420(90)32431-4"},{"key":"e_1_3_3_3_2","volume-title":"Preferred Practice Guidelines: Cataract in the Adult Eye","author":"American Academy of Ophthalmology Cataract and Anterior Segment Panel","year":"2011","unstructured":"American Academy of Ophthalmology Cataract and Anterior Segment Panel. Preferred Practice Guidelines: Cataract in the Adult Eye. San Francisco: American Academy of Ophthalmology, 2011. Available at: www.aao.org\/ppp. Accessed January 31, 2013."},{"key":"e_1_3_3_4_2","doi-asserted-by":"publisher","DOI":"10.1364\/JOSAA.12.002252"},{"key":"e_1_3_3_5_2","doi-asserted-by":"publisher","DOI":"10.1001\/archopht.119.6.881"},{"key":"e_1_3_3_6_2","doi-asserted-by":"publisher","DOI":"10.1001\/jama.288.7.841"},{"key":"e_1_3_3_7_2","unstructured":"Shieber F. Recent Developments in Vision Aging and Driving: 1988\u20131994 . Ann Arbor: University of Michigan Transportation Research Institute. 1994;Oct. Report No. UMTRI-94-26. Available at: http:\/\/deepblue.lib.umich.edu\/handle\/2027.42\/1075. Accessed June 18 2013."},{"key":"e_1_3_3_8_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1600-0420.2006.00860.x"},{"key":"e_1_3_3_9_2","first-page":"64","article-title":"The association of multiple visual impairments with self reported visual disability: SEE project","volume":"42","author":"Rubin GS","year":"2001","unstructured":"Rubin GS, Bandeen-Roche K, Huang GH, et al. The association of multiple visual impairments with self reported visual disability: SEE project. Invest Ophthalmol Vis Sci. 2001;42:64\u201372.","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"e_1_3_3_10_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(98)80354-4"},{"key":"e_1_3_3_11_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0002-9394(99)00219-6"},{"key":"e_1_3_3_12_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(89)80003-3"},{"key":"e_1_3_3_13_2","doi-asserted-by":"publisher","DOI":"10.1001\/archopht.1996.01100130521004"},{"key":"e_1_3_3_14_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(89)80005-7"},{"key":"e_1_3_3_15_2","first-page":"21","volume-title":"Cataract Surgery: Technique, Complications & Management","author":"Masket S","year":"1995","unstructured":"Masket S, Belani S. Preoperative evaluation of the patient with visually significant cataract. In: , Steinert RF, ed. Cataract Surgery: Technique, Complications & Management. Philadelphia: W. B. Saunders Co.; 1995:21\u201332."},{"key":"e_1_3_3_16_2","doi-asserted-by":"publisher","DOI":"10.1038\/eye.1990.100"},{"key":"e_1_3_3_17_2","doi-asserted-by":"publisher","DOI":"10.1136\/bjo.80.9.799"},{"key":"e_1_3_3_18_2","unstructured":"BAT Brightness Acuity Tester (Product No. BAT-1000) instruction manual. Available at: https:\/\/marco.zendesk.com\/hc\/enus\/articles\/201585446-Brightness-Acuity-Tester-BAT-1000-Instruction-Manual. Accessed January 31 2013."},{"key":"e_1_3_3_19_2","first-page":"108","article-title":"Assessing the reliability, discriminative ability, and validity of disability glare tests","volume":"34","author":"Elliot DB","year":"1993","unstructured":"Elliot DB, Bullimore MA. Assessing the reliability, discriminative ability, and validity of disability glare tests. Invest Ophthalmol Vis Sci. 1993;34:108\u2013119.","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"e_1_3_3_20_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(01)00844-6"},{"key":"e_1_3_3_21_2","doi-asserted-by":"publisher","DOI":"10.1097\/OPX.0b013e318141fe75"},{"key":"e_1_3_3_22_2","unstructured":"Sensitivity Analysis of Headlamp Parameters Affecting Visibility and Glare United States Department of Transportation and National Highway Traffic Safety Administration"},{"key":"e_1_3_3_23_2","unstructured":"Kalich ME Lewis LJ Mora A et al.for the US Army Aeromedical Research Laboratory Fort Rucker AL (USAARL). Report no 2009\u201318: Review of Efforts to Develop a Low Luminance-Level Disability Glare Tester. Sensory Research Division. Sept 2009 . Available at: http:\/\/www.dtic.mil\/cgi-bin\/GetTRDoc?Location=U2&doc=GetTRDoc.pdf&AD=ADA511514. Accessed June 18 2013."},{"key":"e_1_3_3_24_2","doi-asserted-by":"publisher","DOI":"10.1080\/09286580590932752"},{"key":"e_1_3_3_25_2","first-page":"317","article-title":"Confirmation of the validity of the psychophysical light scattering factor","volume":"35","author":"Whitaker D","year":"1994","unstructured":"Whitaker D, Elliott DB, Steen R. Confirmation of the validity of the psychophysical light scattering factor. Invest Ophthalmol Vis Sci. 1994;35:317\u2013321.","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"e_1_3_3_26_2","first-page":"412","volume-title":"Proceedings of the 5th International Driving Symposium on Human Factors in Driver Assessment, Training and Vehicle Design","author":"Fullerton M","year":"2009","unstructured":"Fullerton M, Peli E. Development of a system to study the impact of headlight glare in a driving simulator. Proceedings of the 5th International Driving Symposium on Human Factors in Driver Assessment, Training and Vehicle Design. Iowa City: University of Iowa; 2009:412\u2013418."},{"key":"e_1_3_3_27_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081-597X-19970701-16"}],"container-title":["Journal of Refractive Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.healio.com\/doiresolver?doi=10.3928\/1081597X-20150225-03","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,5,2]],"date-time":"2023-05-02T21:54:16Z","timestamp":1683064456000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.healio.com\/doi\/10.3928\/1081597X-20150225-03"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2015,3]]},"references-count":26,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2015,3]]}},"alternative-id":["10.3928\/1081597X-20150225-03"],"URL":"https:\/\/doi.org\/10.3928\/1081597x-20150225-03","relation":{},"ISSN":["1081-597X"],"issn-type":[{"value":"1081-597X","type":"print"}],"subject":[],"published":{"date-parts":[[2015,3]]}}}