{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,31]],"date-time":"2026-10-31T01:03:59Z","timestamp":1793408639378,"version":"4.5.0"},"reference-count":25,"publisher":"SLACK, Inc.","issue":"9","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Refract Surg"],"published-print":{"date-parts":[[2015,9]]},"abstract":"<jats:sec><jats:title>PURPOSE:<\/jats:title><jats:p>To evaluate long-term outcomes of wavefront-guided LASIK with a new advanced aberrometer.<\/jats:p><\/jats:sec><jats:sec><jats:title>METHODS:<\/jats:title><jats:p>Fifty eyes of 25 LASIK candidates with myopia and\/or astigmatism underwent aberrometry (iDesign Advanced WaveScan; Abbott Medical Optics, Santa Ana, CA), femtosecond laser-assisted flap creation, and excimer ablation. Uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), spherical equivalent (SEQ), and astigmatism outcomes were measured at 1, 3, 6, and 12 months postoperatively.<\/jats:p><\/jats:sec><jats:sec><jats:title>RESULTS:<\/jats:title><jats:p>The sphere, cylinder, and SEQ were \u22124.29 \u00b1 1.94, \u22120.75 \u00b1 0.76, and \u22124.67 \u00b1 2.01 diopters (D), respectively, preoperatively and 0.03 \u00b1 0.13, \u22120.09 \u00b1 0.13, and \u22120.02 \u00b1 0.14 D, respectively, 12 months postoperatively (<jats:italic>P<\/jats:italic>&lt; .001). The postoperative log-MAR CDVA (\u22120.07 \u00b1 0.09) and UDVA (\u22120.04 \u00b1 0.09) were better than the preoperative logMAR CDVA (0.07 \u00b1 0.10) (<jats:italic>P<\/jats:italic>&lt; .01). Ninety-four percent achieved a 12-month logMAR UDVA of 0.0 or less (20\/20 or better Snellen) and 100% achieved 0.3 or less (20\/40 or better Snellen), compared to a preoperative logMAR CDVA of 0.0 or worse in 54% and 0.3 or less in 100%. Postoperative SEQ was within \u00b10.50 D in 98%. The regression plot for achieved (y) vs intended (x) correction at 12 months was (y = 0.98 \u00d7 \u2212 0.09,<jats:italic>R<\/jats:italic><jats:sup>2<\/jats:sup>= 0.99,<jats:italic>P<\/jats:italic>&lt; .001). No cases lost CDVA. The target and 12-month surgically induced astigmatisms (TIA and SIA) were 0.91 \u00b1 0.75 and 0.82 \u00b1 0.70, respectively. The regression plot between them was SIA = 0.91 \u00d7 TIA \u2212 0.01 (<jats:italic>R<\/jats:italic><jats:sup>2<\/jats:sup>= 0.95,<jats:italic>P<\/jats:italic>&lt; .001). The angle of error was \u22120.29\u00b0 \u00b1 12.6\u00b0 and index of success was 0.13 \u00b1 0.25. There was only a mild, nonsignificant increase of higher-order aberrations after surgery, and the postoperative wavefront was stable on follow-up.<\/jats:p><\/jats:sec><jats:sec><jats:title>CONCLUSIONS:<\/jats:title><jats:p>Wavefront-guided LASIK with iDesign aberrometry appears to be safe and effective in this long-term, consecutive case series.<\/jats:p><jats:p><jats:bold>[<jats:italic>J Refract Surg.<\/jats:italic>2015;31(9):600\u2013606.]<\/jats:bold><\/jats:p><\/jats:sec>","DOI":"10.3928\/1081597x-20150820-05","type":"journal-article","created":{"date-parts":[[2015,9,9]],"date-time":"2015-09-09T14:12:55Z","timestamp":1441807975000},"page":"600-606","source":"Crossref","is-referenced-by-count":9,"title":["Femtosecond Laser-assisted Wavefront-guided LASIK Using a Newer Generation Aberrometer: 1-Year Results"],"prefix":"10.3928","volume":"31","author":[{"given":"Gaurav","family":"Prakash","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dhruv","family":"Srivastava","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Muhammad","family":"Suhail","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"2308","reference":[{"key":"e_1_3_2_2_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20100428-01"},{"key":"e_1_3_2_3_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1444-0938.2009.00362.x"},{"key":"e_1_3_2_4_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2010.11.025"},{"key":"e_1_3_2_5_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081-597X-20030101-04"},{"key":"e_1_3_2_6_2","doi-asserted-by":"publisher","DOI":"10.1097\/OPX.0b013e3182333a50"},{"key":"e_1_3_2_7_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2008.04.010"},{"key":"e_1_3_2_8_2","unstructured":"Coleman SC. High-definition wavefront: 5X resolution. Accessed October 20 2014 from http:\/\/www.eyeworld.org\/ews-upplementarticle.php?id=281"},{"key":"e_1_3_2_9_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20131029-02"},{"key":"e_1_3_2_10_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20140815-01"},{"key":"e_1_3_2_11_2","first-page":"5","volume-title":"American Academy of Ophthalmology Focal Points 2008 Module","author":"Schallhorn SC","year":"2008","unstructured":"Schallhorn SC. Wavefront-guided LASIK. In: American Academy of Ophthalmology. American Academy of Ophthalmology Focal Points 2008 Module. San Francisco: Author; 2008;26:5. [ebook]"},{"key":"e_1_3_2_12_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20140903-01"},{"key":"e_1_3_2_13_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(13)80617-7"},{"key":"e_1_3_2_14_2","doi-asserted-by":"crossref","first-page":"S424","DOI":"10.3928\/1081597X-20080401-20","article-title":"Wavefront-optimized versus wavefront-guided LASIK for myopic astigmatism with the ALLEGRETTO WAVE: three-month results of a prospective FDA trial","volume":"24","author":"Stonecipher KG","year":"2008","unstructured":"Stonecipher KG, Kezirian GM. Wavefront-optimized versus wavefront-guided LASIK for myopic astigmatism with the ALLEGRETTO WAVE: three-month results of a prospective FDA trial. J Refract Surg. 2008;24:S424\u2013S430.","journal-title":"J Refract Surg"},{"key":"e_1_3_2_15_2","first-page":"362","article-title":"Laser in situ keratomileusis in adult patients with anisometropic amblyopia","volume":"6","author":"Agca A","year":"2013","unstructured":"Agca A, Ozg\u00fcrhan EB, Baz O, et al. Laser in situ keratomileusis in adult patients with anisometropic amblyopia. Int J Ophthalmol. 2013;6:362\u2013369.","journal-title":"Int J Ophthalmol"},{"key":"e_1_3_2_16_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081-597X-20070501-05"},{"key":"e_1_3_2_17_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2013.08.050"},{"key":"e_1_3_2_18_2","first-page":"498","article-title":"Visual performance after conventional LASIK and wavefront-guided LASIK with iris-registration: results at 1 year","volume":"6","author":"Zhang J","year":"2013","unstructured":"Zhang J, Zhou YH, Li R, Tian L. Visual performance after conventional LASIK and wavefront-guided LASIK with iris-registration: results at 1 year. Int J Ophthalmol. 2013;6:498\u2013504.","journal-title":"Int J Ophthalmol"},{"key":"e_1_3_2_19_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2013.05.010"},{"key":"e_1_3_2_20_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2012.07.041"},{"key":"e_1_3_2_21_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2011.11.018"},{"key":"e_1_3_2_22_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2011.03.019"},{"key":"e_1_3_2_23_2","doi-asserted-by":"publisher","DOI":"10.1136\/bjo.2008.152579"},{"key":"e_1_3_2_24_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2008.07.014"},{"key":"e_1_3_2_25_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2004.12.050"},{"key":"e_1_3_2_26_2","doi-asserted-by":"publisher","DOI":"10.2147\/OPTH.S24316"}],"container-title":["Journal of Refractive Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.healio.com\/doiresolver?doi=10.3928\/1081597X-20150820-05","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,5,30]],"date-time":"2025-05-30T14:29:43Z","timestamp":1748615383000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.healio.com\/doi\/10.3928\/1081597X-20150820-05"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2015,9]]},"references-count":25,"journal-issue":{"issue":"9","published-print":{"date-parts":[[2015,9]]}},"alternative-id":["10.3928\/1081597X-20150820-05"],"URL":"https:\/\/doi.org\/10.3928\/1081597x-20150820-05","relation":{},"ISSN":["1081-597X"],"issn-type":[{"value":"1081-597X","type":"print"}],"subject":[],"published":{"date-parts":[[2015,9]]}}}