{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,28]],"date-time":"2026-03-28T01:00:18Z","timestamp":1774659618911,"version":"3.50.1"},"reference-count":33,"publisher":"SLACK, Inc.","issue":"2","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Refract Surg"],"published-print":{"date-parts":[[2016,2]]},"abstract":"<jats:sec>\n            <jats:title>PURPOSE:<\/jats:title>\n            <jats:p>To investigate refractive outcomes and induction of corneal higher order aberrations (HOAs) in eyes with large pupil to corneal vertex offset that underwent LASIK for hyperopia using an aberration-neutral profile with corneal vertex centration and asymmetric offset.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>METHODS:<\/jats:title>\n            <jats:p>\n              In this retrospective consecutive review, 26 patients (46 eyes) who underwent LASIK performed by one surgeon using the AMARIS 750S excimer laser platform and Carriazo-Pendular microkeratome (both from SCHWIND eye-tech-solutions, Kleinostheim, Germany) for flap creation were retrospectively analyzed. Only eyes targeted for plano and with a pupil to corneal vertex offset greater than 200\n              <jats:italic>\u00b5<\/jats:italic>\n              m were included. The preoperative metrics were correlated with the outcomes at 3 and 6 months postoperatively.\n            <\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>RESULTS:<\/jats:title>\n            <jats:p>\n              The mean spherical equivalent was +3.43 \u00b1 1.30 diopters (D) preoperatively and +0.21 \u00b1 0.61 D at last postoperative visit (\n              <jats:italic>P<\/jats:italic>\n              &lt; .0001). Mean refractive astigmatism was 1.09 \u00b1 1.06 D preoperatively, and 0.39 \u00b1 0.43 D at last postoperative visit. Postoperative uncorrected distance visual acuity of 20\/25 or better was achieved in 74%, 65%, and 79% of eyes at 1, 3, and 6 months, respectively, compared to 85% corrected distance visual acuity of 20\/25 or better preoperatively. Statistically significant correlation was observed between preoperative and postoperative aberration values for vertical trefoil (\n              <jats:italic>P<\/jats:italic>\n              &lt; .0005), vertical coma (\n              <jats:italic>P<\/jats:italic>\n              &lt; .0005), oblique tetrafoil (\n              <jats:italic>P<\/jats:italic>\n              &lt; .0001), secondary cardinal astigmatism (\n              <jats:italic>P<\/jats:italic>\n              &lt; .05), cardinal tetrafoil (\n              <jats:italic>P<\/jats:italic>\n              &lt; .05), and secondary vertical trefoil (\n              <jats:italic>P<\/jats:italic>\n              &lt; .05).\n            <\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>CONCLUSIONS:<\/jats:title>\n            <jats:p>LASIK for high levels of hyperopia using corneal vertex centration with asymmetric offset was safe and predictable. Maintaining postoperative keratometry less than 49.00 D after hyperopic LASIK and centering on corneal vertex may reduce the induction of coma compared to other profiles or centration strategies.<\/jats:p>\n            <jats:p>\n              <jats:bold>\n                [\n                <jats:italic>J Refract Surg.<\/jats:italic>\n                2016;32(2):78\u201383.]\n              <\/jats:bold>\n            <\/jats:p>\n          <\/jats:sec>","DOI":"10.3928\/1081597x-20151119-04","type":"journal-article","created":{"date-parts":[[2016,2,9]],"date-time":"2016-02-09T13:22:42Z","timestamp":1455024162000},"page":"78-83","source":"Crossref","is-referenced-by-count":23,"title":["LASIK for Hyperopia Using an Aberration-Neutral Profile With an Asymmetric Offset Centration"],"prefix":"10.3928","volume":"32","author":[{"given":"Samuel","family":"Arba-Mosquera","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Diego","family":"de Ortueta","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"2308","reference":[{"key":"e_1_3_2_2_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081-597X-20040501-03"},{"key":"e_1_3_2_3_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2005.05.004"},{"key":"e_1_3_2_4_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2007.09.045"},{"key":"e_1_3_2_5_2","doi-asserted-by":"publisher","DOI":"10.1167\/4.4.4"},{"key":"e_1_3_2_6_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081-597X-20010701-01"},{"key":"e_1_3_2_7_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(03)00576-5"},{"key":"e_1_3_2_8_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20090401-03"},{"key":"e_1_3_2_9_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20100114-06"},{"key":"e_1_3_2_10_2","first-page":"27","article-title":"The angle kappa in ametropia","volume":"3","author":"Giovanni F","year":"1988","unstructured":"Giovanni F, Siracusano B, Cusmano R. The angle kappa in ametropia. New Trends Ophthalmol. 1988;3:27\u201333.","journal-title":"New Trends Ophthalmol"},{"key":"e_1_3_2_11_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081-597X-20070501-06"},{"key":"e_1_3_2_12_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2011.03.034"},{"key":"e_1_3_2_13_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20130719-08"},{"key":"e_1_3_2_14_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20120703-01"},{"key":"e_1_3_2_15_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2014.06.028"},{"key":"e_1_3_2_16_2","doi-asserted-by":"publisher","DOI":"10.3921\/joptom.2010.20"},{"key":"e_1_3_2_17_2","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.08-2176"},{"key":"e_1_3_2_18_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0002-9394(01)01401-5"},{"key":"e_1_3_2_19_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20090915-09"},{"key":"e_1_3_2_20_2","doi-asserted-by":"publisher","DOI":"10.1177\/112067210901900605"},{"key":"e_1_3_2_21_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2011.05.040"},{"key":"e_1_3_2_22_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081-597X-20060501-08"},{"key":"e_1_3_2_23_2","doi-asserted-by":"publisher","DOI":"10.1364\/AO.49.00D123"},{"key":"e_1_3_2_24_2","doi-asserted-by":"publisher","DOI":"10.1364\/JOSAA.24.003274"},{"key":"e_1_3_2_25_2","doi-asserted-by":"publisher","DOI":"10.1167\/6.1.1"},{"key":"e_1_3_2_26_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081-597X-20040501-03"},{"key":"e_1_3_2_27_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081-597X-20050101-10"},{"key":"e_1_3_2_28_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(03)00576-5"},{"key":"e_1_3_2_29_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(02)01541-9"},{"key":"e_1_3_2_30_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2007.09.045"},{"key":"e_1_3_2_31_2","doi-asserted-by":"publisher","DOI":"10.1364\/JOSAA.24.003274"},{"key":"e_1_3_2_32_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20100225-01"},{"key":"e_1_3_2_33_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20100428-03"},{"key":"e_1_3_2_34_2","doi-asserted-by":"publisher","DOI":"10.1016\/S1888-4296(11)70047-4"}],"container-title":["Journal of Refractive Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.healio.com\/ophthalmology\/journals\/jrs\/2016-2-32-2\/%7Bc182b144-2887-439a-8a8c-cc67ceb2c957%7D\/lasik-for-hyperopia-using-an-aberration-neutral-profile-with-an-asymmetric-offset-centration","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,5,3]],"date-time":"2023-05-03T12:32:49Z","timestamp":1683117169000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.healio.com\/doi\/10.3928\/1081597X-20151119-04"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,2]]},"references-count":33,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2016,2]]}},"alternative-id":["10.3928\/1081597X-20151119-04"],"URL":"https:\/\/doi.org\/10.3928\/1081597x-20151119-04","relation":{},"ISSN":["1081-597X"],"issn-type":[{"value":"1081-597X","type":"print"}],"subject":[],"published":{"date-parts":[[2016,2]]}}}