{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,17]],"date-time":"2026-10-17T10:49:07Z","timestamp":1792234147997,"version":"4.4.0"},"reference-count":34,"publisher":"SLACK, Inc.","issue":"3","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Refract Surg"],"published-print":{"date-parts":[[2016,3]]},"abstract":"<jats:sec>\n            <jats:title>PURPOSE:<\/jats:title>\n            <jats:p>To assess the repeatability of the corneal topography functions of Orbscan II (Bausch &amp; Lomb, Rochester, NY), OPD-Scan III (Nidek, Gamagori, Japan), and iTrace (Tracey Technologies, Houston, TX) in keratoconic eyes and in a control group of normal patients.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>METHODS:<\/jats:title>\n            <jats:p>In this prospective cohort study, patients were recruited between November 2011 and May 2012. Measurements were performed with a combined Placido-scanning slit system (Orbscan II) and two combined Placido-aberrometer systems (OPD-Scan III and iTrace). Repeatability limit and intraclass correlation coefficients (ICCs) of keratometric readings were calculated.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>RESULTS:<\/jats:title>\n            <jats:p>Fifty-nine keratoconic eyes of 34 patients and 54 normal eyes of 27 patients were included. Three groups were evaluated: all stage I\u2013IV keratoconic eyes (59 eyes), a subgroup consisting of stage I\u2013II keratoconic eyes (41 eyes), and normal eyes (54 eyes). For almost all parameters studied, the repeatability limit was higher in the two groups of keratoconic eyes compared to normal eyes with all three topographers, indicating lower repeatability. For the maximum keratometry measurement, repeatability limit was 1.73, 1.49, and 1.41 diopters (D) in the stage I\u2013IV keratoconic eyes group, 1.11, 1.02, and 0.98 D in the stage I\u2013II keratoconic eyes group, and 0.61, 0.37, and 1.02 D in the normal eyes group with Orbscan II, OPD-Scan III, and iTrace, respectively.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>CONCLUSIONS:<\/jats:title>\n            <jats:p>Topographies performed in keratoconic eyes are less repeatable than those performed in normal eyes. Threshold values of keratometric changes used to ascertain keratoconus progression should be carefully considered. Caution should be taken when interpreting the topographies of such patients. The higher variability should be taken into account before performing any treatment.<\/jats:p>\n            <jats:p>\n              <jats:bold>\n                [\n                <jats:italic>J Refract Surg.<\/jats:italic>\n                2016;32(3):187\u2013192.]\n              <\/jats:bold>\n            <\/jats:p>\n          <\/jats:sec>","DOI":"10.3928\/1081597x-20160113-01","type":"journal-article","created":{"date-parts":[[2016,4,25]],"date-time":"2016-04-25T18:03:37Z","timestamp":1461607417000},"page":"187-192","source":"Crossref","is-referenced-by-count":41,"title":["Repeatability of Keratometry Measurements Obtained With Three Topographers in Keratoconic and Normal Corneas"],"prefix":"10.3928","volume":"32","author":[{"given":"Emmanuel","family":"Guilbert","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alain","family":"Saad","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Maud","family":"Elluard","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alice","family":"Grise-Dulac","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"H\u00e9l\u00e8ne","family":"Rouger","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Damien","family":"Gatinel","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"2308","reference":[{"key":"e_1_3_2_2_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081-597X-19891101-10"},{"key":"e_1_3_2_3_2","doi-asserted-by":"publisher","DOI":"10.1016\/0002-9394(89)90001-9"},{"key":"e_1_3_2_4_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(99)00355-7"},{"key":"e_1_3_2_5_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(99)00195-9"},{"key":"e_1_3_2_6_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2007.03.073"},{"key":"e_1_3_2_7_2","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.11-8803"},{"key":"e_1_3_2_8_2","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.10-5369"},{"key":"e_1_3_2_9_2","first-page":"2019","article-title":"Keratoconus: current perspectives","volume":"7","author":"Vazirani J","year":"2013","unstructured":"Vazirani J, Basu S. Keratoconus: current perspectives. Clin Ophthalmol. 2013;7:2019\u20132030.","journal-title":"Clin Ophthalmol"},{"key":"e_1_3_2_10_2","first-page":"S720","article-title":"A randomized controlled trial of corneal collagen cross-linking in progressive keratoconus: preliminary results","volume":"24","author":"Wittig-Silva C","year":"2008","unstructured":"Wittig-Silva C, Whiting M, Lamoureux E, Lindsay RG, Sullivan LJ, Snibson GR. A randomized controlled trial of corneal collagen cross-linking in progressive keratoconus: preliminary results. J Refract Surg. 2008;24:S720\u2013S725.","journal-title":"J Refract Surg"},{"key":"e_1_3_2_11_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2014.07.029"},{"key":"e_1_3_2_12_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081-597X-20060501-11"},{"key":"e_1_3_2_13_2","first-page":"4847","volume-title":"Biostatistical Analysis","author":"Zar JH","year":"1984","unstructured":"Zar JH. Biostatistical Analysis, 2nd ed. Englewood, NJ: Prentice-Hall; 1984:4847.","edition":"2"},{"key":"e_1_3_2_14_2","volume-title":"Statistics Vocabulary and Symbols","author":"International Organization for Standardization","year":"1977","unstructured":"International Organization for Standardization. Statistics Vocabulary and Symbols. Geneva: Author; 1977:ISO 3534."},{"key":"e_1_3_2_15_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2009.07.033"},{"key":"e_1_3_2_16_2","doi-asserted-by":"publisher","DOI":"10.1097\/OPX.0000000000000421"},{"key":"e_1_3_2_17_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2012.10.033"},{"key":"e_1_3_2_18_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2011.04.033"},{"key":"e_1_3_2_19_2","doi-asserted-by":"publisher","DOI":"10.1097\/00006324-200108000-00012"},{"key":"e_1_3_2_20_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2014.08.043"},{"key":"e_1_3_2_21_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2013.01.029"},{"key":"e_1_3_2_22_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2012.01.033"},{"key":"e_1_3_2_23_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2009.04.036"},{"key":"e_1_3_2_24_2","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.10-5841"},{"key":"e_1_3_2_25_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.clae.2014.04.004"},{"key":"e_1_3_2_26_2","doi-asserted-by":"publisher","DOI":"10.1111\/cxo.12044"},{"key":"e_1_3_2_27_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2011.10.027"},{"key":"e_1_3_2_28_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1475-1313.2011.00868.x"},{"key":"e_1_3_2_29_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2003.06.027"},{"key":"e_1_3_2_30_2","first-page":"4117","article-title":"Optical and visual impact of tear break-up in human eyes","volume":"41","author":"Tutt R","year":"2000","unstructured":"Tutt R, Bradley A, Begley C, Thibos LN. Optical and visual impact of tear break-up in human eyes. Invest Ophthalmol Vis Sci. 2000;41:4117\u20134123.","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"e_1_3_2_31_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(01)00768-4"},{"key":"e_1_3_2_32_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2011.03.041"},{"key":"e_1_3_2_33_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20090401-02"},{"key":"e_1_3_2_34_2","doi-asserted-by":"publisher","DOI":"10.1097\/ICO.0b013e3181915943"},{"key":"e_1_3_2_35_2","doi-asserted-by":"publisher","DOI":"10.1136\/bjo.2010.196493"}],"container-title":["Journal of Refractive Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.healio.com\/ophthalmology\/journals\/jrs\/2016-3-32-3\/%7B0391d00d-6212-4ce8-a80d-848b8f1d7ff3%7D\/repeatability-of-keratometry-measurements-obtained-with-three-topographers-in-keratoconic-and-normal-corneas","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,5,3]],"date-time":"2023-05-03T13:12:16Z","timestamp":1683119536000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.healio.com\/doi\/10.3928\/1081597X-20160113-01"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,3]]},"references-count":34,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2016,3]]}},"alternative-id":["10.3928\/1081597X-20160113-01"],"URL":"https:\/\/doi.org\/10.3928\/1081597x-20160113-01","relation":{},"ISSN":["1081-597X"],"issn-type":[{"value":"1081-597X","type":"print"}],"subject":[],"published":{"date-parts":[[2016,3]]}}}