{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,21]],"date-time":"2026-09-21T17:01:11Z","timestamp":1790010071115,"version":"4.0.1"},"reference-count":23,"publisher":"SLACK, Inc.","issue":"8","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Refract Surg"],"published-print":{"date-parts":[[2017,8,1]]},"abstract":"<jats:sec>\n                    <jats:title>PURPOSE:<\/jats:title>\n                    <jats:p>To study the safety, efficacy, and outcomes of manual cyclotorsion compensation in small incision lenticule extraction (SMILE) for myopic astigmatism.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>METHODS:<\/jats:title>\n                    <jats:p>Eligible patients with myopia from \u22121.00 to \u221210.00 diopters (D) spherical equivalent with a minimum astigmatism of 0.75 D undergoing SMILE were included. Intraoperative cyclotorsion compensation was performed by gently rotating the cone and aligning the 0\u00b0 to 180\u00b0 limbal marks with the horizontal axis of the reticule of the right eye piece of the microscope of the femtosecond laser after activating the suction.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>RESULTS:<\/jats:title>\n                    <jats:p>\n                      In this study, 81 left eyes from 81 patients were analyzed for vector analysis of astigmatism. The mean cyclotorsion was 5.64\u00b0 \u00b1 2.55\u00b0 (range: 2\u00b0 to 12\u00b0). No significant differences were found for surgically induced astigmatism, difference vector, angle of error (AE), correction index, magnitude of error, index of success (IOS), and flattening index between 2 weeks and 3 months postoperatively (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &gt; .05). The eyes were categorized into low (\u2264 1.50 D, n = 37) and high (&gt; 1.50 D, n = 44) cylinder groups. At 3 months, intergroup analysis showed a comparable correction index of 0.97 for the low and 0.93 for the high cylinder groups, suggesting a slight undercorrection of 3% and 7%, respectively (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = .14). However, the AE and IOS were significantly lower in the high compared to the low cylinder group (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = .032 and .024 for AE and IOS, respectively), suggesting better alignment of the treatment in the high cylinder group. However, the mean uncorrected distance visual acuity of both groups was comparable (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = .21), suggesting good visual outcomes in the low cylinder group despite a less favorable IOS.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>CONCLUSIONS:<\/jats:title>\n                    <jats:p>Manual compensation may be a safe, feasible, and effective approach to refine the results of astigmatism with SMILE, especially in higher degrees of cylinders.<\/jats:p>\n                    <jats:p>\n                      <jats:bold>\n                        [\n                        <jats:italic toggle=\"yes\">J Refract Surg.<\/jats:italic>\n                        2017;33(8):506\u2013512.]\n                      <\/jats:bold>\n                    <\/jats:p>\n                  <\/jats:sec>","DOI":"10.3928\/1081597x-20170328-01","type":"journal-article","created":{"date-parts":[[2017,8,8]],"date-time":"2017-08-08T15:45:10Z","timestamp":1502207110000},"page":"506-512","source":"Crossref","is-referenced-by-count":95,"title":["Results of Intraoperative Manual Cyclotorsion Compensation for Myopic Astigmatism in Patients Undergoing Small Incision Lenticule Extraction (SMILE)"],"prefix":"10.3928","volume":"33","author":[{"given":"Sri","family":"Ganesh","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sheetal","family":"Brar","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Archana","family":"Pawar","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"2308","reference":[{"key":"e_1_3_2_2_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2010.05.019"},{"key":"e_1_3_2_3_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0002-9394(01)01401-5"},{"key":"e_1_3_2_4_2","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.08-1766"},{"key":"e_1_3_2_5_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20150820-03"},{"key":"e_1_3_2_6_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.clae.2011.02.012"},{"key":"e_1_3_2_7_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20140903-04"},{"key":"e_1_3_2_8_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2012.11.033"},{"key":"e_1_3_2_9_2","doi-asserted-by":"publisher","DOI":"10.1055\/s-0029-1245894"},{"key":"e_1_3_2_10_2","doi-asserted-by":"publisher","DOI":"10.1136\/bjo.2009.174284"},{"key":"e_1_3_2_11_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2009.10.030"},{"key":"e_1_3_2_12_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(13)80617-7"},{"key":"e_1_3_2_13_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(97)80153-8"},{"key":"e_1_3_2_14_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(97)80021-1"},{"key":"e_1_3_2_15_2","doi-asserted-by":"publisher","DOI":"10.1136\/bjophthalmol-2015-307238"},{"key":"e_1_3_2_16_2","doi-asserted-by":"publisher","DOI":"10.1186\/1471-2415-15-8"},{"key":"e_1_3_2_17_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2013.11.006"},{"key":"e_1_3_2_18_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.joco.2016.05.004"},{"key":"e_1_3_2_19_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(99)00072-3"},{"key":"e_1_3_2_20_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(01)01279-2"},{"key":"e_1_3_2_21_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2003.08.022"},{"key":"e_1_3_2_22_2","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0123408"},{"key":"e_1_3_2_23_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20151021-01"},{"key":"e_1_3_2_24_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20140814-02"}],"container-title":["Journal of Refractive Surgery"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/www.healio.com\/doiresolver?doi=10.3928\/1081597X-20170328-01","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,7,29]],"date-time":"2026-07-29T19:27:07Z","timestamp":1785353227000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.healio.com\/doi\/10.3928\/1081597X-20170328-01"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,8,1]]},"references-count":23,"journal-issue":{"issue":"8","published-print":{"date-parts":[[2017,8,1]]}},"alternative-id":["10.3928\/1081597X-20170328-01"],"URL":"https:\/\/doi.org\/10.3928\/1081597x-20170328-01","relation":{},"ISSN":["1081-597X"],"issn-type":[{"value":"1081-597X","type":"print"}],"subject":[],"published":{"date-parts":[[2017,8,1]]}}}