{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,23]],"date-time":"2026-08-23T14:55:30Z","timestamp":1787496930453,"version":"build-2736575974"},"reference-count":26,"publisher":"SLACK, Inc.","issue":"9","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Refract Surg"],"published-print":{"date-parts":[[2017,9]]},"abstract":"<jats:sec>\n                    <jats:title>PURPOSE:<\/jats:title>\n                    <jats:p>To evaluate and compare biomechanical properties in normal and keratoconic eyes using a dynamic ultra-high-speed Scheimpflug camera equipped with a non-contact tonometer (Corvis ST; Oculus Optikger\u00e4te GmbH, Wetzlar, Germany).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>METHODS:<\/jats:title>\n                    <jats:p>This retrospective study evaluated 89 eyes (47 normal, 42 keratoconic) and a validation arm of 72 eyes (33 normal, 39 keratoconic) using the Corvis ST. A diagnosis of keratoconus was established by clinical findings confirmed by topography and tomography. Dynamic corneal response parameters collected by the Corvis ST (A1 velocity, deformation amplitude [DA], DA Ratio Max 1mm, and Max Inverse Radius) and a stiffness parameter at first applanation (SP-A1) were incorporated into a novel logistic regression equation (DCR index). Area under the receiver operating curve (AUC) was used to assess the sensitivity and specificity of the DCR index.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>RESULTS:<\/jats:title>\n                    <jats:p>\n                      DA, DA Ratio Max 1mm, Max Inverse Radius, and SP-A1 were each found to be statistically significantly different between normal and keratoconic eyes (Mann\u2013Whitney test [independent samples];\n                      <jats:italic>P<\/jats:italic>\n                      = .0077, &lt; .0001, &lt; .0001, and &lt; .0001, respectively; significance level:\n                      <jats:italic>P<\/jats:italic>\n                      &lt; .05). DCR index demonstrated high sensitivity, specificity, and overall correct detection rate (92.9%, 95.7%, and 94.4%, respectively; AUC = 98.5). The sensitivity and overall correct detection rate improved when eyes with Topographical Keratoconus Classification grades (TKC) greater than 0 were reevaluated (from 92.9% to 96.6% and from 94.4% to 96.1%, respectively).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>CONCLUSIONS:<\/jats:title>\n                    <jats:p>Combining multiple biomechanical parameters (A1 velocity, DA, DA Ratio Max 1mm, Max Inverse Radius, and SP-A1) into a logistic regression equation allows for high sensitivity and specificity for distinguishing keratoconic from normal eyes.<\/jats:p>\n                    <jats:p>\n                      <jats:bold>\n                        [\n                        <jats:italic>J Refract Surg.<\/jats:italic>\n                        2017;33(9):625\u2013631.]\n                      <\/jats:bold>\n                    <\/jats:p>\n                  <\/jats:sec>","DOI":"10.3928\/1081597x-20170621-03","type":"journal-article","created":{"date-parts":[[2017,9,7]],"date-time":"2017-09-07T14:16:52Z","timestamp":1504793812000},"page":"625-631","source":"Crossref","is-referenced-by-count":19,"title":["Comparison of Corneal Deformation Parameters in Keratoconic and Normal Eyes Using a Non-contact Tonometer With a Dynamic Ultra-High-Speed Scheimpflug Camera"],"prefix":"10.3928","volume":"33","author":[{"given":"Ryan N.","family":"Mercer","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"suffix":"IV","given":"George O.","family":"Waring","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Cynthia J.","family":"Roberts","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Vishal","family":"Jhanji","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yumeng","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Joao S.","family":"Filho","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"suffix":"Jr.","given":"Richard A.","family":"Hemings","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Karolinne M.","family":"Rocha","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"2308","reference":[{"key":"e_1_3_3_2_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0014-4835(80)80027-3"},{"key":"e_1_3_3_3_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.exer.2006.03.015"},{"key":"e_1_3_3_4_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081-597X-20050901-04"},{"key":"e_1_3_3_5_2","doi-asserted-by":"publisher","DOI":"10.1590\/S0034-72802013000200005"},{"key":"e_1_3_3_6_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2006.09.036"},{"key":"e_1_3_3_7_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2007.04.021"},{"key":"e_1_3_3_8_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.survophthal.2007.08.004"},{"key":"e_1_3_3_9_2","doi-asserted-by":"publisher","DOI":"10.3109\/02713683.2012.669007"},{"key":"e_1_3_3_10_2","doi-asserted-by":"publisher","DOI":"10.1097\/OPX.0b013e3182417223"},{"key":"e_1_3_3_11_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20140521-01"},{"key":"e_1_3_3_12_2","doi-asserted-by":"publisher","DOI":"10.1097\/ICO.0b013e3182490924"},{"key":"e_1_3_3_13_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2005.12.007"},{"key":"e_1_3_3_14_2","doi-asserted-by":"publisher","DOI":"10.2147\/OPTH.S76491"},{"key":"e_1_3_3_15_2","doi-asserted-by":"publisher","DOI":"10.5005\/jp-journals-10025-1069"},{"key":"e_1_3_3_16_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2015.01.014"},{"key":"e_1_3_3_17_2","first-page":"7840284","article-title":"In vivo corneal biomechanical properties with corneal visualization scheimpflug technology in Chinese population","volume":"2016","author":"Wu Y","year":"2016","unstructured":"Wu Y, Tian L, Huang YF. In vivo corneal biomechanical properties with corneal visualization scheimpflug technology in Chinese population. Biomed Res Int. 2016;2016:7840284.","journal-title":"Biomed Res Int"},{"key":"e_1_3_3_18_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20160629-01"},{"key":"e_1_3_3_19_2","article-title":"A new stiffness parameter in air puff induced corneal deformation analysis","volume":"57","author":"Roberts CJ","year":"2016","unstructured":"Roberts CJ, Mahmoud AM, Bons J, et al. A new stiffness parameter in air puff induced corneal deformation analysis. Invest Ophthalmol Vis Sci. 2016;57:ARVO E-Abstract 2390.","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"e_1_3_3_20_2","first-page":"1","article-title":"Development and validation of a correction equation for Corvis tonometry","author":"Joda AA","year":"2015","unstructured":"Joda AA, Shervin MMS, Kook D, Elsheikh A. Development and validation of a correction equation for Corvis tonometry. Computer Methods in Biomechanics and Biomedical Engineering 2015;1\u201311.","journal-title":"Computer Methods in Biomechanics and Biomedical Engineering"},{"key":"e_1_3_3_21_2","first-page":"121","article-title":"Collagen fibril orientation in the human corneal stroma and its implication in keratoconus","volume":"38","author":"Daxer A","year":"1997","unstructured":"Daxer A, Fratzl P. Collagen fibril orientation in the human corneal stroma and its implication in keratoconus. Invest Ophthalmol Vis Sci. 1997;38:121\u2013129.","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"e_1_3_3_22_2","doi-asserted-by":"publisher","DOI":"10.1097\/01.ico.0000208820.32614.00"},{"key":"e_1_3_3_23_2","doi-asserted-by":"publisher","DOI":"10.1155\/2014\/204191"},{"key":"e_1_3_3_24_2","doi-asserted-by":"publisher","DOI":"10.5301\/ejo.5000184"},{"key":"e_1_3_3_25_2","doi-asserted-by":"publisher","DOI":"10.1097\/ICO.0000000000000598"},{"key":"e_1_3_3_26_2","doi-asserted-by":"publisher","DOI":"10.1155\/2014\/147516"},{"key":"e_1_3_3_27_2","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.13-13715"}],"container-title":["Journal of Refractive Surgery"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/www.healio.com\/doiresolver?doi=10.3928\/1081597X-20170621-03","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,5,3]],"date-time":"2023-05-03T05:03:57Z","timestamp":1683090237000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.healio.com\/doi\/10.3928\/1081597X-20170621-03"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,9]]},"references-count":26,"journal-issue":{"issue":"9","published-print":{"date-parts":[[2017,9]]}},"alternative-id":["10.3928\/1081597X-20170621-03"],"URL":"https:\/\/doi.org\/10.3928\/1081597x-20170621-03","relation":{},"ISSN":["1081-597X"],"issn-type":[{"value":"1081-597X","type":"print"}],"subject":[],"published":{"date-parts":[[2017,9]]}}}