{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,12]],"date-time":"2026-02-12T14:49:31Z","timestamp":1770907771160,"version":"3.50.1"},"reference-count":42,"publisher":"SLACK, Inc.","issue":"1","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Refract Surg"],"published-print":{"date-parts":[[2019,1]]},"abstract":"<jats:sec>\n            <jats:title>PURPOSE:<\/jats:title>\n            <jats:p>To evaluate the long-term visual and refractive outcomes, optical quality, and stability of the cornea and axial length after small incision lenticule extraction (SMILE) for the correction of high myopia with a maximum myopic meridian exceeding 10.00 diopters (D).<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>METHODS:<\/jats:title>\n            <jats:p>Via a prospective cohort study, 53 eyes (53 patients) with a maximum myopic meridian exceeding 10.00 D were corrected with a VisuMax femtosecond laser (version 3.0; Carl Zeiss Meditec AG, Jena, Germany) at the Zhongshan Ophthalmic Center of Sun Yat-sen University. Refractive outcomes, aberrations, axial length, and corneal curvature were evaluated preoperatively and at 1, 3, and 15 months postoperatively.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>RESULTS:<\/jats:title>\n            <jats:p>\n              At 15 months postoperatively, the efficacy and safety indexes were 0.91 \u00b1 0.25 and 1.15 \u00b1 0.18, respectively. A total of 72% of eyes were within \u00b10.50 D and 89% were within \u00b11.00 D of the attempted spherical equivalent, respectively. From 1 to 15 months postoperatively, the significant regression was \u22120.24 \u00b1 0.28 D (\n              <jats:italic>P<\/jats:italic>\n              &lt; .001) on manifest refraction and \u22120.43 \u00b1 0.54 D (\n              <jats:italic>P<\/jats:italic>\n              &lt; .001) on anterior corneal curvature. In addition, a significant increase of 0.20 \u00b5m (\n              <jats:italic>P<\/jats:italic>\n              = .016) was observed in the spherical aberration. No significant change was observed in posterior corneal curvature (\n              <jats:italic>P<\/jats:italic>\n              &gt; .999), including mean keratometry or astigmatism, or in the ocular axis length from 1 to 15 months postoperatively (26.82 \u00b1 0.93 and 26.82 \u00b1 0.95 mm, respectively,\n              <jats:italic>P<\/jats:italic>\n              &gt; .99).\n            <\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>CONCLUSIONS:<\/jats:title>\n            <jats:p>SMILE had long-term safety, efficacy, and predictability when treating high myopia with a maximum myopic meridian exceeding 10.00 D. Both a manifest refraction regression of \u22120.24 D and a significant spherical aberration increase of 0.20 \u00b5m were observed between 1 and 15 months postoperatively, due to the increased anterior corneal curvature.<\/jats:p>\n            <jats:p>\n              <jats:bold>\n                [\n                <jats:italic>J Refract Surg<\/jats:italic>\n                . 2019;35(1):31\u201339.]\n              <\/jats:bold>\n            <\/jats:p>\n          <\/jats:sec>","DOI":"10.3928\/1081597x-20181126-01","type":"journal-article","created":{"date-parts":[[2019,1,11]],"date-time":"2019-01-11T18:29:41Z","timestamp":1547231381000},"page":"31-39","source":"Crossref","is-referenced-by-count":11,"title":["15-Month Visual Outcomes and Corneal Power Changes of SMILE in Treating High Myopia With Maximum Myopic Meridian Exceeding 10.00 D"],"prefix":"10.3928","volume":"35","author":[{"given":"Xiaonan","family":"Yang","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Fang","family":"Liu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Manli","family":"Liu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Quan","family":"Liu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shengbei","family":"Weng","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Haiqin","family":"Lin","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"2308","reference":[{"key":"e_1_3_2_2_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2008.05.033"},{"key":"e_1_3_2_3_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20150923-11"},{"key":"e_1_3_2_4_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.clae.2016.01.007"},{"key":"e_1_3_2_5_2","doi-asserted-by":"publisher","DOI":"10.1136\/bjophthalmol-2015-306822"},{"key":"e_1_3_2_6_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20141113-07"},{"key":"e_1_3_2_7_2","doi-asserted-by":"publisher","DOI":"10.1111\/aos.13609"},{"key":"e_1_3_2_8_2","first-page":"S90","article-title":"Biomechanical and wound healing characteristics of corneas after excimer laser keratorefractive surgery: is there a difference between advanced surface ablation and sub-Bowman's keratomileusis?","volume":"24","author":"Dawson DG","year":"2008","unstructured":"Dawson DG, Grossniklaus HE, McCarey BE, Edelhauser HF. Biomechanical and wound healing characteristics of corneas after excimer laser keratorefractive surgery: is there a difference between advanced surface ablation and sub-Bowman's keratomileusis? J Refract Surg. 2008;24:S90\u2013S96.","journal-title":"J Refract Surg"},{"key":"e_1_3_2_9_2","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.16-20211"},{"key":"e_1_3_2_10_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20130617-03"},{"key":"e_1_3_2_11_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20160502-03"},{"key":"e_1_3_2_12_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2018.01.021"},{"key":"e_1_3_2_13_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2015.04.001"},{"key":"e_1_3_2_14_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2015.08.006"},{"key":"e_1_3_2_15_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2015.02.008"},{"key":"e_1_3_2_16_2","doi-asserted-by":"publisher","DOI":"10.2147\/OPTH.S124580"},{"key":"e_1_3_2_17_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20170328-01"},{"key":"e_1_3_2_18_2","doi-asserted-by":"publisher","DOI":"10.1097\/00004397-200343030-00003"},{"key":"e_1_3_2_19_2","doi-asserted-by":"publisher","DOI":"10.1186\/s12886-015-0051-x"},{"key":"e_1_3_2_20_2","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.08-2853"},{"key":"e_1_3_2_21_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20160310-01"},{"key":"e_1_3_2_22_2","doi-asserted-by":"publisher","DOI":"10.1097\/ICU.0000000000000383"},{"key":"e_1_3_2_23_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2015.05.013"},{"key":"e_1_3_2_24_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2017.04.040"},{"key":"e_1_3_2_25_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20120921-03"},{"key":"e_1_3_2_26_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2013.04.044"},{"key":"e_1_3_2_27_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1755-3768.2012.02406.x"},{"key":"e_1_3_2_28_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2013.07.043"},{"key":"e_1_3_2_29_2","first-page":"1","article-title":"Phakic intraocular lenses for the treatment of refractive errors: an evidence-based analysis","volume":"9","author":"Health Quality Ontario","year":"2009","unstructured":"Health Quality Ontario. Phakic intraocular lenses for the treatment of refractive errors: an evidence-based analysis. Ont Health Technol Assess Ser. 2009;9:1\u2013120.","journal-title":"Ont Health Technol Assess Ser"},{"key":"e_1_3_2_30_2","doi-asserted-by":"publisher","DOI":"10.1136\/bjophthalmol-2017-310164"},{"key":"e_1_3_2_31_2","first-page":"376","article-title":"Long-term vision-threatening complications of phakic intraocular lens implantation for high myopia","volume":"7","author":"Sayman Muslubas IB","year":"2014","unstructured":"Sayman Muslubas IB, Kandemir B, Aydin Oral AY, Kugu S, Dastan M. Long-term vision-threatening complications of phakic intraocular lens implantation for high myopia. Int J Ophthalmol. 2014;7:376\u2013380.","journal-title":"Int J Ophthalmol"},{"key":"e_1_3_2_32_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2013.11.006"},{"key":"e_1_3_2_33_2","doi-asserted-by":"publisher","DOI":"10.1097\/ICO.0000000000001617"},{"key":"e_1_3_2_34_2","doi-asserted-by":"publisher","DOI":"10.1136\/bmjopen-2015-010993"},{"key":"e_1_3_2_35_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2014.06.013"},{"key":"e_1_3_2_36_2","doi-asserted-by":"publisher","DOI":"10.2174\/1874364101812010214"},{"key":"e_1_3_2_37_2","doi-asserted-by":"publisher","DOI":"10.1186\/s12886-018-0712-7"},{"key":"e_1_3_2_38_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20170602-01"},{"key":"e_1_3_2_39_2","doi-asserted-by":"publisher","DOI":"10.1186\/s40662-015-0031-5"},{"key":"e_1_3_2_40_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20150303-01"},{"key":"e_1_3_2_41_2","doi-asserted-by":"publisher","DOI":"10.1097\/ICO.0000000000001264"},{"key":"e_1_3_2_42_2","doi-asserted-by":"publisher","DOI":"10.1155\/2017\/4921090"},{"key":"e_1_3_2_43_2","doi-asserted-by":"publisher","DOI":"10.4274\/tjo.22605"}],"container-title":["Journal of Refractive Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.healio.com\/doiresolver?doi=10.3928\/1081597X-20181126-01","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,5,3]],"date-time":"2023-05-03T03:08:15Z","timestamp":1683083295000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.healio.com\/doi\/10.3928\/1081597X-20181126-01"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,1]]},"references-count":42,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2019,1]]}},"alternative-id":["10.3928\/1081597X-20181126-01"],"URL":"https:\/\/doi.org\/10.3928\/1081597x-20181126-01","relation":{},"ISSN":["1081-597X"],"issn-type":[{"value":"1081-597X","type":"print"}],"subject":[],"published":{"date-parts":[[2019,1]]}}}