{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,18]],"date-time":"2026-11-18T16:39:18Z","timestamp":1795019958333,"version":"4.10.1"},"reference-count":36,"publisher":"SLACK, Inc.","issue":"4","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Refract Surg"],"published-print":{"date-parts":[[2019,4]]},"abstract":"<jats:sec>\n            <jats:title>PURPOSE:<\/jats:title>\n            <jats:p>To compare centration and functional optical zone (FOZ) after small incision lenticule extraction (SMILE) and femtosecond laser\u2013assisted in situ keratomileusis (LASIK).<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>METHODS:<\/jats:title>\n            <jats:p>In this prospective, randomized, single-masked, paired-eyed, clinical trial, 70 patients received SMILE in one eye and LASIK in the other eye for myopia and myopic astigmatism. FOZ was calculated using custom software on 3-month postoperative refractive power maps (Pentacam HR; Oculus Optikger\u00e4te GmbH, Wetzlar, Germany). Programmed treatment area was defined as the total area of the programmed OZ plus the transition zone. Centration was evaluated by the linear distance between FOZ centroid and the pupil center and the corneal apex.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>RESULTS:<\/jats:title>\n            <jats:p>\n              The average preoperative spherical equivalent (\u22125.38 \u00b1 1.65 vs \u22125.45 \u00b1 1.61 diopters [D]), postoperative spherical equivalent (0.05 \u00b1 0.39 vs 0.06 \u00b1 0.39 D), uncorrected distance visual acuity (0.01 \u00b1 0.13 vs 0.00 \u00b1 0.08 logMAR), and corrected distance visual acuity (\u22120.07 \u00b1 0.10 vs \u22120.07 \u00b1 0.10 logMAR) were comparable in SMILE- and LASIK-treated eyes of the 60 patients with complete datasets (\n              <jats:italic>P<\/jats:italic>\n              &gt; .419). Postoperative increase in spherical aberration was lower in SMILE than in LASIK (0.08 \u00b1 0.16 vs 0.17 \u00b1 0.18 \u00b5m,\n              <jats:italic>P<\/jats:italic>\n              = .002). The FOZ area was significantly larger in SMILE than in LASIK (30.25 \u00b1 3.60 vs 29.21 \u00b1 3.72 mm\n              <jats:sup>2<\/jats:sup>\n              ), despite the smaller programmed OZ diameter (6.48 \u00b1 0.08 vs 6.52 \u00b1 0.11 mm) and smaller programmed treatment area (33.87 \u00b1 0.81 vs 46.30 \u00b1 2.61 mm\n              <jats:sup>2<\/jats:sup>\n              ,\n              <jats:italic>P<\/jats:italic>\n              &lt; .037). Pupil centration (0.43 \u00b1 0.21 vs 0.41 \u00b1 0.22 mm) and apex centration (0.48 \u00b1 0.24 vs 0.48 \u00b1 0.22 mm) were comparable between SMILE and LASIK (\n              <jats:italic>P<\/jats:italic>\n              &gt; .694).\n            <\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>CONCLUSIONS:<\/jats:title>\n            <jats:p>SMILE created a larger FOZ than LASIK, despite the smaller programmed OZ. This may be due to a difference in the biomechanical response between the two procedures. Visual outcome and centration were comparable between SMILE and LASIK.<\/jats:p>\n            <jats:p>\n              <jats:bold>\n                [\n                <jats:italic>J Refract Surg<\/jats:italic>\n                . 2019;35(4):230\u2013237.]\n              <\/jats:bold>\n            <\/jats:p>\n          <\/jats:sec>","DOI":"10.3928\/1081597x-20190313-01","type":"journal-article","created":{"date-parts":[[2019,4,15]],"date-time":"2019-04-15T11:52:20Z","timestamp":1555329140000},"page":"230-237","source":"Crossref","is-referenced-by-count":80,"title":["Functional Optical Zone and Centration Following SMILE and LASIK: A Prospective, Randomized, Contralateral Eye Study"],"prefix":"10.3928","volume":"35","author":[{"given":"Iben B.","family":"Damgaard","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marcus","family":"Ang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ashraf M.","family":"Mahmoud","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mohamed","family":"Farook","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Cynthia J.","family":"Roberts","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jodhbir S.","family":"Mehta","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"2308","reference":[{"key":"e_1_3_2_2_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2013.12.026"},{"key":"e_1_3_2_3_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20140903-04"},{"key":"e_1_3_2_4_2","doi-asserted-by":"publisher","DOI":"10.1097\/ICO.0b013e31819ba450"},{"key":"e_1_3_2_5_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20150225-01"},{"key":"e_1_3_2_6_2","first-page":"1","article-title":"The effect of optical zone decentration on lower- and higher-order aberrations after photorefractive keratectomy in a cat model","volume":"48","author":"B\u00fchren J","year":"2010","unstructured":"B\u00fchren J, Yoon G, Kenner S, MacRae S. The effect of optical zone decentration on lower- and higher-order aberrations after photorefractive keratectomy in a cat model. Invest Ophthalmol Vis Sci. 2010;48:1\u201322.","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"e_1_3_2_7_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(97)80204-0"},{"key":"e_1_3_2_8_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20150820-03"},{"key":"e_1_3_2_9_2","first-page":"2275","article-title":"Optical zone diameters for photorefractive corneal surgery","volume":"34","author":"Roberts CW","year":"1993","unstructured":"Roberts CW, Koester CJ. Optical zone diameters for photorefractive corneal surgery. Invest Ophthalmol Vis Sci. 1993;34:2275\u20132281.","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"e_1_3_2_10_2","doi-asserted-by":"publisher","DOI":"10.1001\/archopht.119.8.1159"},{"key":"e_1_3_2_11_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081-597X-20011101-05"},{"key":"e_1_3_2_12_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20170111-01"},{"key":"e_1_3_2_13_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(02)01324-X"},{"key":"e_1_3_2_14_2","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.06-0867"},{"key":"e_1_3_2_15_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2004.10.043"},{"key":"e_1_3_2_16_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(02)01322-6"},{"key":"e_1_3_2_17_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2004.04.073"},{"key":"e_1_3_2_18_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20150727-03"},{"key":"e_1_3_2_19_2","doi-asserted-by":"publisher","DOI":"10.1136\/bjophthalmol-2013-303415"},{"key":"e_1_3_2_20_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20180425-02"},{"key":"e_1_3_2_21_2","doi-asserted-by":"publisher","DOI":"10.1186\/1745-6215-13-75"},{"key":"e_1_3_2_22_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0161-6420(93)31500-9"},{"key":"e_1_3_2_23_2","doi-asserted-by":"publisher","DOI":"10.1136\/bjo.2009.174284"},{"key":"e_1_3_2_24_2","doi-asserted-by":"publisher","DOI":"10.1097\/MD.0000000000006076"},{"key":"e_1_3_2_25_2","first-page":"1159","article-title":"Comparison of outcomes of conventional WaveLight\u00ae Allegretto Wave\u00ae and Technolas\u00ae excimer lasers in myopic laser in situ keratomileusis","volume":"6","author":"Han DC","year":"2012","unstructured":"Han DC, Chen J, Htoon HM, Tan DT, Mehta J. Comparison of outcomes of conventional WaveLight\u00ae Allegretto Wave\u00ae and Technolas\u00ae excimer lasers in myopic laser in situ keratomileusis. Clin Ophthalmol. 2012;6:1159.","journal-title":"Clin Ophthalmol"},{"key":"e_1_3_2_26_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081-597X-20070501-06"},{"key":"e_1_3_2_27_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20161220-01"},{"key":"e_1_3_2_28_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20090915-09"},{"key":"e_1_3_2_29_2","first-page":"624","article-title":"Comparison of visual effects of FS-LASIK for myopia centered on the coaxially sighted corneal light reflex or the line of sight","volume":"10","author":"Zhang J","year":"2017","unstructured":"Zhang J, Zhang SS, Yu Q, Lian JC. Comparison of visual effects of FS-LASIK for myopia centered on the coaxially sighted corneal light reflex or the line of sight. Int J Ophthalmol. 2017;10:624\u2013631.","journal-title":"Int J Ophthalmol"},{"key":"e_1_3_2_30_2","doi-asserted-by":"publisher","DOI":"10.1097\/ICO.0000000000000383"},{"key":"e_1_3_2_31_2","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.13-13714"},{"key":"e_1_3_2_32_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2009.01.022"},{"key":"e_1_3_2_33_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20150122-10"},{"key":"e_1_3_2_34_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2013.08.065"},{"key":"e_1_3_2_35_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081-597X-20000701-03"},{"key":"e_1_3_2_36_2","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.10-7093"},{"key":"e_1_3_2_37_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2010.03.002"}],"container-title":["Journal of Refractive Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.healio.com\/doiresolver?doi=10.3928\/1081597X-20190313-01","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,5,3]],"date-time":"2023-05-03T03:04:05Z","timestamp":1683083045000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.healio.com\/doi\/10.3928\/1081597X-20190313-01"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,4]]},"references-count":36,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2019,4]]}},"alternative-id":["10.3928\/1081597X-20190313-01"],"URL":"https:\/\/doi.org\/10.3928\/1081597x-20190313-01","relation":{},"ISSN":["1081-597X"],"issn-type":[{"value":"1081-597X","type":"print"}],"subject":[],"published":{"date-parts":[[2019,4]]}}}