{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,28]],"date-time":"2026-10-28T23:17:03Z","timestamp":1793229423713,"version":"4.5.0"},"reference-count":31,"publisher":"SLACK, Inc.","issue":"6","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Refract Surg"],"published-print":{"date-parts":[[2019,6]]},"abstract":"<jats:sec>\n            <jats:title>PURPOSE:<\/jats:title>\n            <jats:p>To test the detection of subclinical corneal ectasia using integrated Scheimpflug tomography and biomechanical assessment in a Japanese population.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>METHODS:<\/jats:title>\n            <jats:p>This prospective, case\u2013control study included 23 patients with very asymmetric ectasia (VAE) and 70 normal controls. Patients with VAE had defined clinical ectasia in one eye and a fellow eye with normal topography (VAE-NT). Objective topography for confirming normal topography in VAE-NT cases included having 0% similarity and 0% severity derived from Placido-disk based topography. Scheimpflug-based corneal tomography and corneal biomechanical assessment were performed. The Belin\/Ambr\u00f3sio Enhanced Ectasia Deviation index (BAD-D), Corvis Biomechanical Index (CBI), and Tomographic Biomechanical Index (TBI) were compared and their discriminating ability for detecting ectasia was assessed.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>RESULTS:<\/jats:title>\n            <jats:p>For differentiating normal and VAE-NT eyes, the areas under the receiver operating curve for the BAD-D, CBI, and TBI were 0.668, 0.660, and 0.751, respectively. The TBI cut-off of 0.259 provided 52.17% sensitivity and 88.57% specificity. Fourteen VAE-NT cases (60.9%) were abnormal in at least one of the criteria of the BAD-D &gt; 1.60 (39.1%), CBI &gt; 0.5 (26.1%), or TBI &gt; 0.29 (43.5%). Conversely, nine VAE-NT cases (39.1%) exhibited normal values for the BAD-D, CBI, and TBI.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>CONCLUSIONS:<\/jats:title>\n            <jats:p>In the current study, 40% of VAE-NT eyes were classified as normal by the BAD-D, CBI, and TBI. Although some of these cases may truly represent unilateral ectasia, further advances are needed to enhance ectasia detection and characterize the susceptibility for ectasia progression.<\/jats:p>\n            <jats:p>\n              <jats:bold>\n                [\n                <jats:italic>J Refract Surg.<\/jats:italic>\n                2019;35(6):383\u2013390.]\n              <\/jats:bold>\n            <\/jats:p>\n          <\/jats:sec>","DOI":"10.3928\/1081597x-20190417-01","type":"journal-article","created":{"date-parts":[[2019,6,11]],"date-time":"2019-06-11T17:44:32Z","timestamp":1560275072000},"page":"383-390","source":"Crossref","is-referenced-by-count":48,"title":["Detection of Subclinical Corneal Ectasia Using Corneal Tomographic and Biomechanical Assessments in a Japanese Population"],"prefix":"10.3928","volume":"35","author":[{"given":"Shizuka","family":"Koh","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"suffix":"Jr.","given":"Renato","family":"Ambr\u00f3sio","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ryota","family":"Inoue","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Naoyuki","family":"Maeda","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Atsuya","family":"Miki","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kohji","family":"Nishida","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"2308","reference":[{"key":"e_1_3_3_2_2","doi-asserted-by":"publisher","DOI":"10.1016\/0039-6257(84)90094-8"},{"key":"e_1_3_3_3_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0039-6257(97)00119-7"},{"key":"e_1_3_3_4_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081-597X-20051101-15"},{"key":"e_1_3_3_5_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20130318-01"},{"key":"e_1_3_3_6_2","first-page":"1426","article-title":"Computer-assisted corneal topography: high-resolution graphic presentation and analysis of keratoscopy","volume":"25","author":"Klyce SD","year":"1984","unstructured":"Klyce SD. Computer-assisted corneal topography: high-resolution graphic presentation and analysis of keratoscopy. Invest Ophthalmol Vis Sci. 1984;25:1426\u20131435.","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"e_1_3_3_7_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20160629-01"},{"key":"e_1_3_3_8_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20170213-01"},{"key":"e_1_3_3_9_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20170426-02"},{"key":"e_1_3_3_10_2","doi-asserted-by":"publisher","DOI":"10.1097\/ICO.0000000000001639"},{"key":"e_1_3_3_11_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20180705-02"},{"key":"e_1_3_3_12_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2018.08.054"},{"key":"e_1_3_3_13_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2018.10.030"},{"key":"e_1_3_3_14_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20181012-01"},{"key":"e_1_3_3_15_2","first-page":"2749","article-title":"Automated keratoconus screening with corneal topography analysis","volume":"35","author":"Maeda N","year":"1994","unstructured":"Maeda N, Klyce SD, Smolek MK, Thompson HW. Automated keratoconus screening with corneal topography analysis. Invest Ophthalmol Vis Sci. 1994;35:2749\u20132757.","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"e_1_3_3_16_2","doi-asserted-by":"publisher","DOI":"10.1001\/archopht.1995.01100070044023"},{"key":"e_1_3_3_17_2","first-page":"2290","article-title":"Current keratoconus detection methods compared with a neural network approach","volume":"38","author":"Smolek MK","year":"1997","unstructured":"Smolek MK, Klyce SD. Current keratoconus detection methods compared with a neural network approach. Invest Ophthalmol Vis Sci. 1997;38:2290\u20132299.","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"e_1_3_3_18_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(99)00195-9"},{"key":"e_1_3_3_19_2","doi-asserted-by":"publisher","DOI":"10.1136\/bjophthalmol-2017-310355"},{"key":"e_1_3_3_20_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20100428-02"},{"key":"e_1_3_3_21_2","doi-asserted-by":"publisher","DOI":"10.2307\/2531595"},{"key":"e_1_3_3_22_2","first-page":"23","article-title":"Enhanced screening for ectasia risk prior to laser vision correction","volume":"6","author":"Ambrosio R","year":"2017","unstructured":"Ambrosio R, Belin MW. Enhanced screening for ectasia risk prior to laser vision correction. Int J Kerat Ect Cor Dis. 2017;6:23\u201333.","journal-title":"Int J Kerat Ect Cor Dis"},{"key":"e_1_3_3_23_2","doi-asserted-by":"publisher","DOI":"10.3928\/15428877-20120102-03"},{"key":"e_1_3_3_24_2","first-page":"842","article-title":"The \u201cforme fruste\u201d of keratoconus [article in German]","volume":"73","author":"Amsler M","year":"1961","unstructured":"Amsler M. The \u201cforme fruste\u201d of keratoconus [article in German]. Wien Klin Wochenschr. 1961;73:842\u2013843.","journal-title":"Wien Klin Wochenschr"},{"key":"e_1_3_3_25_2","doi-asserted-by":"publisher","DOI":"10.1136\/bjo.2008.147371"},{"key":"e_1_3_3_26_2","doi-asserted-by":"publisher","DOI":"10.1097\/ICO.0000000000000408"},{"key":"e_1_3_3_27_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0161-6420(97)30123-7"},{"key":"e_1_3_3_28_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2003.06.020"},{"key":"e_1_3_3_29_2","doi-asserted-by":"publisher","DOI":"10.1097\/ICO.0000000000001295"},{"key":"e_1_3_3_30_2","doi-asserted-by":"publisher","DOI":"10.1097\/ICO.0000000000001890"},{"key":"e_1_3_3_31_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2015.09.021"},{"key":"e_1_3_3_32_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2018.08.005"}],"container-title":["Journal of Refractive Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.healio.com\/doiresolver?doi=10.3928\/1081597X-20190417-01","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,5,3]],"date-time":"2023-05-03T01:34:02Z","timestamp":1683077642000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.healio.com\/doi\/10.3928\/1081597X-20190417-01"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,6]]},"references-count":31,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2019,6]]}},"alternative-id":["10.3928\/1081597X-20190417-01"],"URL":"https:\/\/doi.org\/10.3928\/1081597x-20190417-01","relation":{},"ISSN":["1081-597X"],"issn-type":[{"value":"1081-597X","type":"print"}],"subject":[],"published":{"date-parts":[[2019,6]]}}}