{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,25]],"date-time":"2026-02-25T21:21:48Z","timestamp":1772054508387,"version":"3.50.1"},"reference-count":28,"publisher":"SLACK, Inc.","issue":"10","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Refract Surg"],"published-print":{"date-parts":[[2019,10]]},"abstract":"<jats:sec>\n            <jats:title>PURPOSE:<\/jats:title>\n            <jats:p>To compare the outcomes of intracorneal ring segments (ICRS) implantation in keratoconic eyes with a similar tomographic pattern, using two different manufacturers' nomograms for surgical planning.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>METHODS:<\/jats:title>\n            <jats:p>ICRS were implanted alternately in patients with the same tomographic pattern of keratoconus divided into two groups according to the surgical planning proposed by the ICRS manufacturers (Keraring, Mediphacos, Belo Horizonte, Brazil, and Ferrara Ring, AJL Ophthalmics, Vitoria, Spain). Visual, refractive, keratometric, corneal aberrometry, and optical quality changes were evaluated during a 6-month follow-up. Corneal and manifest refractive astigmatic changes were also analyzed using the double-angle polar plot and the Alpins vectorial method through the following components: target induced astigmatism, surgically induced astigmatism, difference vector, correction index, angle of error, index of success, flattening effect, and torque.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>RESULTS:<\/jats:title>\n            <jats:p>\n              After ICRS implantation, both groups showed significant improvement (\n              <jats:italic>P<\/jats:italic>\n              &lt; .05) in visual and keratometric data. Corneal aberrometric changes and optical quality improvement were also statistically significant in both groups, except for trefoil (\n              <jats:italic>P<\/jats:italic>\n              &gt; .05 in all intervals). The Alpins method analysis showed a better performance in the Keraring group, but with no statistically significant difference between groups (\n              <jats:italic>P<\/jats:italic>\n              &gt; .05). Comparison between groups showed a statistically significant difference only in tomographic astigmatism in double-angle polar plot analysis (\n              <jats:italic>P<\/jats:italic>\n              = .03), with more significant improvement in the Keraring group.\n            <\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>CONCLUSIONS:<\/jats:title>\n            <jats:p>Both manufacturers' nomograms resulted in statistically significant improvement in most of the parameters analyzed, with greater correction of corneal tomographic astigmatism in the group operated on according to the spherical equivalent\/tomographic astigmatism nomogram.<\/jats:p>\n            <jats:p>\n              <jats:bold>\n                [\n                <jats:italic>J Refract Surg.<\/jats:italic>\n                2019;35(10):673\u2013683.]\n              <\/jats:bold>\n            <\/jats:p>\n          <\/jats:sec>","DOI":"10.3928\/1081597x-20190916-01","type":"journal-article","created":{"date-parts":[[2019,10,14]],"date-time":"2019-10-14T17:31:14Z","timestamp":1571074274000},"page":"673-683","source":"Crossref","is-referenced-by-count":11,"title":["Intracorneal Ring Segments Implantation Outcomes Using Two Different Manufacturers' Nomograms for Keratoconus Surgery"],"prefix":"10.3928","volume":"35","author":[{"given":"Guilherme","family":"Rocha","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ludmila Nascimento Pinto","family":"Silva","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Lu\u00eds Fernando Oliveira Borges","family":"Chaves","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Pedro","family":"Bertino","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Leonardo","family":"Torquetti","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Luciene Barbosa","family":"de Sousa","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"2308","reference":[{"key":"e_1_3_2_2_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0039-6257(97)00119-7"},{"issue":"13","key":"e_1_3_2_3_2","first-page":"2537","article-title":"Baseline findings in the Collaborative Longitudinal Evaluation of Keratoconus (CLEK) Study","volume":"39","author":"Zadnik K","year":"1998","unstructured":"Zadnik K, Barr JT, Edrington TB, et al. Baseline findings in the Collaborative Longitudinal Evaluation of Keratoconus (CLEK) Study. Invest Ophthalmol Vis Sci. 1998;39(13):2537\u20132546. PMID:9856763","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"e_1_3_2_4_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2007.12.022"},{"key":"e_1_3_2_5_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2008.05.028"},{"key":"e_1_3_2_6_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2006.11.033"},{"key":"e_1_3_2_7_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2006.10.041"},{"key":"e_1_3_2_8_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2006.02.044"},{"key":"e_1_3_2_9_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2006.01.064"},{"key":"e_1_3_2_10_2","doi-asserted-by":"publisher","DOI":"10.1097\/01.ico.0000167883.63266.60"},{"key":"e_1_3_2_11_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2006.08.057"},{"key":"e_1_3_2_12_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(02)01484-0"},{"key":"e_1_3_2_13_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2006.02.012"},{"key":"e_1_3_2_14_2","doi-asserted-by":"publisher","DOI":"10.1097\/IIO.0b013e3181e21b76"},{"key":"e_1_3_2_15_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2017.12.020"},{"issue":"3","key":"e_1_3_2_16_2","first-page":"305","article-title":"Outcomes of single segment implantation of conventional Intacs versus Intacs SK for keratoconus","volume":"9","author":"Hashemian MN","year":"2014","unstructured":"Hashemian MN, Zare MA, Mohammadpour M, Rahimi F, Fallah MR, Panah FK. Outcomes of single segment implantation of conventional Intacs versus Intacs SK for keratoconus. J Ophthalmic Vis Res. 2014;9(3):305\u2013309. PMID:25667729","journal-title":"J Ophthalmic Vis Res"},{"key":"e_1_3_2_17_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2012.02.039"},{"key":"e_1_3_2_18_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2009.12.031"},{"key":"e_1_3_2_19_2","first-page":"195","volume-title":"Keratoconus: Recent Advances in Diagnosis and Treatment","author":"Kili\u00e7 A","unstructured":"Kili\u00e7 A, Ali\u00f3 J, Vega Estrada A. Intracorneal ring segments: types, indications and outcomes. In: , Ali\u00f3 JL, ed. Keratoconus: Recent Advances in Diagnosis and Treatment.New York: Springer International Publishing; 195\u2013208."},{"key":"e_1_3_2_20_2","first-page":"92","article-title":"The new Ferrara ring nomogram: the importance of corneal asphericity in ring selection","author":"Ferrara P","year":"2010","unstructured":"Ferrara P, Torquetti L. The new Ferrara ring nomogram: the importance of corneal asphericity in ring selection. Vision Pan-America. 2010:92\u201395.","journal-title":"Vision Pan-America"},{"key":"e_1_3_2_21_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(00)00798-7"},{"key":"e_1_3_2_22_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(13)80617-7"},{"key":"e_1_3_2_23_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(98)80075-8"},{"key":"e_1_3_2_24_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2018.07.027"},{"key":"e_1_3_2_25_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2012.08.020"},{"key":"e_1_3_2_26_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2010.04.029"},{"key":"e_1_3_2_27_2","first-page":"178","article-title":"Corneal asphericity changes after implantation of intrastromal corneal ring segments in keratoconus","volume":"1","author":"Torquetti L","year":"2010","unstructured":"Torquetti L, Ferrara P. Corneal asphericity changes after implantation of intrastromal corneal ring segments in keratoconus. J Emmetropia. 2010;1:178\u2013181.","journal-title":"J Emmetropia"},{"key":"e_1_3_2_28_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0161-6420(02)01773-6"},{"issue":"5","key":"e_1_3_2_29_2","first-page":"802","article-title":"Clinical outcomes after implantation of a new intrastromal corneal ring with 140-degree of arc in patients with corneal ectasia","volume":"11","author":"Sandes J","year":"2018","unstructured":"Sandes J, Stival LRS, de \u00c1vila MP, et al. Clinical outcomes after implantation of a new intrastromal corneal ring with 140-degree of arc in patients with corneal ectasia. Int J Ophthalmol. 2018;11(5):802\u2013806. https:\/\/doi.org\/10.18240\/ijo.2018.05.14 PMID:29862179","journal-title":"Int J Ophthalmol"}],"container-title":["Journal of Refractive Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.healio.com\/doiresolver?doi=10.3928\/1081597X-20190916-01","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,5,3]],"date-time":"2023-05-03T08:40:12Z","timestamp":1683103212000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.healio.com\/doi\/10.3928\/1081597X-20190916-01"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,10]]},"references-count":28,"journal-issue":{"issue":"10","published-print":{"date-parts":[[2019,10]]}},"alternative-id":["10.3928\/1081597X-20190916-01"],"URL":"https:\/\/doi.org\/10.3928\/1081597x-20190916-01","relation":{},"ISSN":["1081-597X"],"issn-type":[{"value":"1081-597X","type":"print"}],"subject":[],"published":{"date-parts":[[2019,10]]}}}