{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,18]],"date-time":"2026-03-18T01:55:23Z","timestamp":1773798923623,"version":"3.50.1"},"reference-count":28,"publisher":"SLACK, Inc.","issue":"2","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Refract Surg"],"published-print":{"date-parts":[[2020,2]]},"abstract":"<jats:sec>\n            <jats:title>PURPOSE:<\/jats:title>\n            <jats:p>To evaluate visual outcomes 6 years after hybrid bi-aspheric multifocal central laser in situ keratomileusis for presbyopia correction (PresbyLASIK) treatments.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>METHODS:<\/jats:title>\n            <jats:p>Thirty-eight eyes of 19 patients consecutively treated with central PresbyLASIK were assessed. The mean age of the patients was 51 \u00b1 3 years at the time of treatment with a mean spherical equivalent refraction of \u22120.57 \u00b1 1.98 diopters (D) and mean astigmatism of 0.58 \u00b1 0.57 D. Monocular corrected distance visual acuity (CDVA), corrected near visual acuity (CNVA), and distance-corrected near visual acuity (DCNVA), uncorrected distance visual acuity (UDVA), uncorrected intermediate visual acuity (UIVA), distance-corrected intermediate visual acuity (DCIVA), and uncorrected near visual acuity (UNVA) were assessed preoperatively and postoperatively for the dominant eye, non-dominant eye, and binocularly. Subjective quality of vision and near vision were assessed using the 10-item, Rasch-scaled, Quality of Vision (QoV) Questionnaire and Near Activity Visual Questionnaire (NAVQ), respectively.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>RESULTS:<\/jats:title>\n            <jats:p>At 6 years postoperatively, mean binocular UDVA was 20\/18 \u00b1 4 and mean binocular UNVA and UIVA were 0.11 \u00b1 0.13 and \u22120.08 \u00b1 0.08 logRAD, respectively. Spherical equivalent showed a slow hyperopic drift of +0.10 D per year with refractive astigmatism stable from 6 weeks postoperatively. Defocus curves showed an improvement of 0.4 Snellen lines at best focus from 1 to 6 years of follow-up, reaching preoperative levels. Compared to the preoperative status, the corneal and ocular spherical aberrations (at a 6-mm diameter) decreased and were stable from 3 months of follow-up. Questionnaires revealed a postoperative unaided QoV score comparable to preoperative scores and with an improved postoperative unaided NAVQ score compared to preoperative scores with best correction.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>CONCLUSIONS:<\/jats:title>\n            <jats:p>Presbyopic treatment using a hybrid bi-aspheric micro-monovision ablation profile is safe and efficacious even after 6 years postoperatively. The postoperative outcomes indicate improvements in binocular vision at far, intermediate, and near distances. An 8% re-treatment rate should be considered to increase satisfaction levels, including a 3% reversal rate.<\/jats:p>\n            <jats:p>\n              <jats:bold>\n                [\n                <jats:italic>J Refract Surg<\/jats:italic>\n                . 2020;36(2):89\u201396.]\n              <\/jats:bold>\n            <\/jats:p>\n          <\/jats:sec>","DOI":"10.3928\/1081597x-20200102-01","type":"journal-article","created":{"date-parts":[[2020,2,7]],"date-time":"2020-02-07T19:34:48Z","timestamp":1581104088000},"page":"89-96","source":"Crossref","is-referenced-by-count":17,"title":["Long-term Outcomes After LASIK Using a Hybrid Bi-aspheric Micro-monovision Ablation Profile for Presbyopia Correction"],"prefix":"10.3928","volume":"36","author":[{"given":"Michiel H.A.","family":"Luger","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Colm","family":"McAlinden","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Phillip J.","family":"Buckhurst","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"James S.","family":"Wolffsohn","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shwetabh","family":"Verma","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Samuel","family":"Arba-Mosquera","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"2308","reference":[{"key":"e_1_3_2_2_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.preteyeres.2018.09.004"},{"key":"e_1_3_2_3_2","doi-asserted-by":"publisher","DOI":"10.1097\/IIO.0b013e318277442e"},{"key":"e_1_3_2_4_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2010.08.055"},{"key":"e_1_3_2_5_2","first-page":"132","article-title":"Computer-based primary visual cortex training for treatment of low myopia and early presbyopia","volume":"105","author":"Durrie D","year":"2007","unstructured":"Durrie D, McMinn PS. Computer-based primary visual cortex training for treatment of low myopia and early presbyopia. Trans Am Ophthalmol Soc. 2007;105:132\u2013138.","journal-title":"Trans Am Ophthalmol Soc"},{"key":"e_1_3_2_6_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2007.09.018"},{"key":"e_1_3_2_7_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081-597X-20040903-16"},{"key":"e_1_3_2_8_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081-597X-20060501-06"},{"key":"e_1_3_2_9_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081-597X-20040903-17"},{"key":"e_1_3_2_10_2","doi-asserted-by":"publisher","DOI":"10.1097\/ICO.0b013e31825f02f5"},{"key":"e_1_3_2_11_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2015.05.021"},{"key":"e_1_3_2_12_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2008.04.031"},{"key":"e_1_3_2_13_2","doi-asserted-by":"publisher","DOI":"10.1097\/OPX.0b013e3182993856"},{"key":"e_1_3_2_14_2","doi-asserted-by":"publisher","DOI":"10.1001\/archophthalmol.2012.1603"},{"key":"e_1_3_2_15_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2010.10.061"},{"key":"e_1_3_2_16_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2012.11.005"},{"key":"e_1_3_2_17_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.clae.2007.01.004"},{"key":"e_1_3_2_18_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20131223-01"},{"key":"e_1_3_2_19_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2009.05.059"},{"key":"e_1_3_2_20_2","doi-asserted-by":"publisher","DOI":"10.1364\/BOE.7.003471"},{"key":"e_1_3_2_21_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2008.09.002"},{"key":"e_1_3_2_22_2","doi-asserted-by":"publisher","DOI":"10.1186\/s40662-016-0062-6"},{"key":"e_1_3_2_23_2","doi-asserted-by":"publisher","DOI":"10.1136\/bjophthalmol-2015-307672"},{"key":"e_1_3_2_24_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2014.05.051"},{"key":"e_1_3_2_25_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20090101-07"},{"issue":"9","key":"e_1_3_2_26_2","first-page":"1446","article-title":"Comparison of FDA safety and efficacy data for KAMRA and Raindrop corneal inlays","volume":"10","author":"Moshirfar M","year":"2017","unstructured":"Moshirfar M, Desautels JD, Wallace RT, Koen N, Hoopes PC. Comparison of FDA safety and efficacy data for KAMRA and Raindrop corneal inlays. Int J Ophthalmol. 2017;10(9):1446\u20131451.","journal-title":"Int J Ophthalmol"},{"key":"e_1_3_2_27_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2011.01.027"},{"key":"e_1_3_2_28_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081-597X-20071101-07"},{"key":"e_1_3_2_29_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20080301-12"}],"container-title":["Journal of Refractive Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.healio.com\/doiresolver?doi=10.3928\/1081597X-20200102-01","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,1,9]],"date-time":"2024-01-09T18:59:23Z","timestamp":1704826763000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.healio.com\/doi\/10.3928\/1081597X-20200102-01"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,2]]},"references-count":28,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2020,2]]}},"alternative-id":["10.3928\/1081597X-20200102-01"],"URL":"https:\/\/doi.org\/10.3928\/1081597x-20200102-01","relation":{},"ISSN":["1081-597X"],"issn-type":[{"value":"1081-597X","type":"print"}],"subject":[],"published":{"date-parts":[[2020,2]]}}}