{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,20]],"date-time":"2025-11-20T18:46:01Z","timestamp":1763664361900},"reference-count":30,"publisher":"SLACK, Inc.","issue":"10","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Refract Surg"],"published-print":{"date-parts":[[2020,10]]},"abstract":"<jats:sec>\n            <jats:title>PURPOSE:<\/jats:title>\n            <jats:p>To investigate the Pentacam (Oculus Optikger\u00e4te) Scheimpflug tomography findings in Chinese patients with different corneal diameters.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>METHODS:<\/jats:title>\n            <jats:p>This prospective cross-sectional study included candidates for correction of myopia with normal tomography (ABCD keratoconus grading system, stage 0). The participants were grouped according to their horizontal corneal diameters. Pentacam ectasia detection indices were compared between different corneal diameter\u2013based groups.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>RESULTS:<\/jats:title>\n            <jats:p>\n              A total of 643 eyes were included (corneal diameter \u2a7d 11 mm, n = 206; 11 to 12 mm, n = 219; \u2a7e 12 mm, n = 218). The corneal powers and the thinnest pachymetry were negatively correlated with corneal diameter (linear regression analysis,\n              <jats:italic>P<\/jats:italic>\n              &lt; .001). However, the corneal astigmatism was positively correlated with corneal diameter (\n              <jats:italic>R<\/jats:italic>\n              <jats:sup>2<\/jats:sup>\n              = 0.03,\n              <jats:italic>P<\/jats:italic>\n              &lt; .001). Both the front (FE) and back (BE) elevations were negatively correlated with corneal diameter (FE:\n              <jats:italic>R<\/jats:italic>\n              <jats:sup>2<\/jats:sup>\n              = 0.027,\n              <jats:italic>P<\/jats:italic>\n              &lt; .001; BE: R\n              <jats:sup>2<\/jats:sup>\n              = 0.274,\n              <jats:italic>P<\/jats:italic>\n              &lt; .001). The three pachymetric progression indices (PPI) (minimum, maximum, and average) were negatively correlated with corneal diameter (PPImin:\n              <jats:italic>R<\/jats:italic>\n              <jats:sup>2<\/jats:sup>\n              = 0.164,\n              <jats:italic>P<\/jats:italic>\n              &lt; .001; PPImax:\n              <jats:italic>R<\/jats:italic>\n              <jats:sup>2<\/jats:sup>\n              = 0.06,\n              <jats:italic>P<\/jats:italic>\n              &lt; .001; PPIavg:\n              <jats:italic>R<\/jats:italic>\n              <jats:sup>2<\/jats:sup>\n              = 0.158,\n              <jats:italic>P<\/jats:italic>\n              &lt; .001). The maximum Ambr\u00f3sio's relational thickness (ARTmax) also was positively correlated with corneal diameter (\n              <jats:italic>R<\/jats:italic>\n              <jats:sup>2<\/jats:sup>\n              = 0.031,\n              <jats:italic>P<\/jats:italic>\n              &lt; .001). Five normalized indices were negatively correlated with corneal diameter (deviation of normality of the front elevation [Df]:\n              <jats:italic>R<\/jats:italic>\n              <jats:sup>2<\/jats:sup>\n              = 0.122,\n              <jats:italic>P<\/jats:italic>\n              &lt; .001; deviation of normality of the back elevation [Db]:\n              <jats:italic>R<\/jats:italic>\n              <jats:sup>2<\/jats:sup>\n              = 0.47,\n              <jats:italic>P<\/jats:italic>\n              &lt; .001; deviation of normality of pachymetric progression [Dp]:\n              <jats:italic>R<\/jats:italic>\n              <jats:sup>2<\/jats:sup>\n              = 0.159,\n              <jats:italic>P<\/jats:italic>\n              &lt; .001; deviation of normality of relational thickness [Da]:\n              <jats:italic>R<\/jats:italic>\n              <jats:sup>2<\/jats:sup>\n              = .031,\n              <jats:italic>P<\/jats:italic>\n              &lt; .001; Belin\/Ambr\u00f3sio Enhanced Ectasia display:\n              <jats:italic>R<\/jats:italic>\n              <jats:sup>2<\/jats:sup>\n              = 0.32,\n              <jats:italic>P<\/jats:italic>\n              &lt; .001) and Dt was positively correlated with corneal diameter (\n              <jats:italic>R<\/jats:italic>\n              <jats:sup>2<\/jats:sup>\n              = 0.015,\n              <jats:italic>P<\/jats:italic>\n              = .002). Additionally, it was noted that corneal diameter had the greatest influence on Db, Belin\/Ambr\u00f3sio Enhanced Ectasia display (BAD-D), and BE.\n            <\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>CONCLUSIONS:<\/jats:title>\n            <jats:p>Corneal diameter has an influence on the BAD parameters, especially Db, BAD-D, and BE, and therefore should be incorporated as an additional variable in BAD analysis. The analytical dimensions should be individualized for eyes with individual corneal diameter.<\/jats:p>\n            <jats:p>\n              <jats:bold>\n                [\n                <jats:italic>J Refract Surg<\/jats:italic>\n                . 2020;36(10):688\u2013695.]\n              <\/jats:bold>\n            <\/jats:p>\n          <\/jats:sec>","DOI":"10.3928\/1081597x-20200730-02","type":"journal-article","created":{"date-parts":[[2020,10,9]],"date-time":"2020-10-09T11:16:31Z","timestamp":1602242191000},"page":"688-695","source":"Crossref","is-referenced-by-count":14,"title":["Pentacam Scheimpflug Tomography Findings in Chinese Patients With Different Corneal Diameters"],"prefix":"10.3928","volume":"36","author":[{"given":"Lan","family":"Ding","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jifang","family":"Wang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Lingling","family":"Niu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Wanru","family":"Shi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yishan","family":"Qian","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"2308","reference":[{"issue":"3","key":"e_1_3_2_2_2","first-page":"177","article-title":"Pentacam\u00ae corneal tomography for screening of refractive surgery candidates: a review of the literature, part I","volume":"8","author":"Motlagh MN","year":"2019","unstructured":"Motlagh MN, Moshirfar M, Murri MS, et al. Pentacam\u00ae corneal tomography for screening of refractive surgery candidates: a review of the literature, part I. Med Hypothesis Discov Innov Ophthalmol. 2019;8(3):177\u2013203.","journal-title":"Med Hypothesis Discov Innov Ophthalmol"},{"key":"e_1_3_2_3_2","doi-asserted-by":"publisher","DOI":"10.3928\/15428877-20120102-03"},{"issue":"7","key":"e_1_3_2_4_2","first-page":"515","article-title":"[Comparison of biometry with the Pentacam AXL, IOLMaster 700 and IOLMaster 500 in cataract patients]","volume":"55","author":"Wang ZY","year":"2019","unstructured":"Wang ZY, Yang WL, Li DJ, et al. [Comparison of biometry with the Pentacam AXL, IOLMaster 700 and IOLMaster 500 in cataract patients]. Zhonghua Yan Ke Za Zhi. 2019;55(7):515\u2013521.","journal-title":"Zhonghua Yan Ke Za Zhi"},{"key":"e_1_3_2_5_2","doi-asserted-by":"publisher","DOI":"10.1097\/APO.0000000000000273"},{"key":"e_1_3_2_6_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20110721-01"},{"key":"e_1_3_2_7_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2011.04.030"},{"key":"e_1_3_2_8_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(00)00798-7"},{"key":"e_1_3_2_9_2","doi-asserted-by":"publisher","DOI":"10.1111\/ceo.12821"},{"key":"e_1_3_2_10_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0181-5512(07)79273-2"},{"key":"e_1_3_2_11_2","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.13-13756"},{"key":"e_1_3_2_12_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2014.03.018"},{"key":"e_1_3_2_13_2","doi-asserted-by":"publisher","DOI":"10.1155\/2015\/925414"},{"key":"e_1_3_2_14_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2013.03.023"},{"key":"e_1_3_2_15_2","doi-asserted-by":"publisher","DOI":"10.1007\/s10792-018-1028-6"},{"key":"e_1_3_2_16_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2004.09.047"},{"key":"e_1_3_2_17_2","doi-asserted-by":"publisher","DOI":"10.1136\/bjophthalmol-2013-304132"},{"key":"e_1_3_2_18_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.joco.2016.01.009"},{"key":"e_1_3_2_19_2","doi-asserted-by":"publisher","DOI":"10.1097\/ICL.0000000000000531"},{"key":"e_1_3_2_20_2","doi-asserted-by":"publisher","DOI":"10.1097\/ICO.0000000000001639"},{"key":"e_1_3_2_21_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1755-3768.1988.tb04026.x"},{"key":"e_1_3_2_22_2","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-020-57926-7"},{"key":"e_1_3_2_23_2","doi-asserted-by":"publisher","DOI":"10.1136\/bjophthalmol-2017-310355"},{"key":"e_1_3_2_24_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2015.12.020"},{"key":"e_1_3_2_25_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2018.02.006"},{"key":"e_1_3_2_26_2","doi-asserted-by":"publisher","DOI":"10.5005\/jp-journals-10025-1019"},{"key":"e_1_3_2_27_2","doi-asserted-by":"publisher","DOI":"10.1097\/ICO.0000000000000529"},{"key":"e_1_3_2_28_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2018.05.013"},{"key":"e_1_3_2_29_2","doi-asserted-by":"publisher","DOI":"10.1097\/ICO.0b013e3182a40786"},{"key":"e_1_3_2_30_2","doi-asserted-by":"publisher","DOI":"10.1097\/ICO.0000000000001300"},{"key":"e_1_3_2_31_2","doi-asserted-by":"publisher","DOI":"10.1097\/ICO.0000000000000408"}],"container-title":["Journal of Refractive Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.healio.com\/doiresolver?doi=10.3928\/1081597X-20200730-02","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,5,3]],"date-time":"2023-05-03T13:34:09Z","timestamp":1683120849000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.healio.com\/doi\/10.3928\/1081597X-20200730-02"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,10]]},"references-count":30,"journal-issue":{"issue":"10","published-print":{"date-parts":[[2020,10]]}},"alternative-id":["10.3928\/1081597X-20200730-02"],"URL":"https:\/\/doi.org\/10.3928\/1081597x-20200730-02","relation":{},"ISSN":["1081-597X"],"issn-type":[{"value":"1081-597X","type":"print"}],"subject":[],"published":{"date-parts":[[2020,10]]}}}