{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,2]],"date-time":"2026-07-02T22:55:58Z","timestamp":1783032958747,"version":"3.54.6"},"reference-count":37,"publisher":"SLACK, Inc.","issue":"4","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Refract Surg"],"published-print":{"date-parts":[[2021,4]]},"abstract":"<jats:sec>\n            <jats:title>PURPOSE:<\/jats:title>\n            <jats:p>To evaluate the clinical outcomes including patient-reported outcome measures in a sample of eyes undergoing bilateral cataract surgery with implantation of a new model of presbyopia-correcting intraocular lens (IOL).<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>METHODS:<\/jats:title>\n            <jats:p>This non-randomized prospective case series enrolled 206 eyes of 103 patients undergoing phacoemulsification cataract surgery with bilateral implantation of the TECNIS Synergy IOL (Johnson &amp; Johnson Vision). High and low contrast visual acuity, refractive, defocus curve, and patient-reported visual performance (Catquest-9SF questionnaire) outcomes were evaluated during a 3-month follow-up.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>RESULTS:<\/jats:title>\n            <jats:p>\n              A total of 96.1% (99 of 103) and 91.3% (94 of 103) of patients achieved binocular postoperative uncorrected distance (UDVA) and near visual acuity (UNVA) of 0.00 logMAR (20\/20), respectively. Mean postoperative mesopic UNVA for both eyes was 0.14 \u00b1 0.03 logMAR. Likewise, mean binocular UDVA and UNVA were 0.00 \u00b1 0.03 and 0.04 \u00b1 0.02 logMAR. An almost flat mean defocus curve was obtained, with visual acuities between 0.00 and 0.10 logMAR for most defocus levels in both eyes. A reduction of contrast led to a limited but statistically significant change in UNVA in both eyes (\n              <jats:italic>P<\/jats:italic>\n              &lt; .001). The Rasch calibrated scoring of item 2 and the Rasch calibrated mean score of the Catquest-9SF questionnaire increased significantly with surgery (\n              <jats:italic>P<\/jats:italic>\n              &lt; .001).\n            <\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>CONCLUSIONS:<\/jats:title>\n            <jats:p>This new presbyopia-correcting IOL provides a continuous range of functional focus, with a limited deterioration under mesopic conditions, which is perceived as a satisfactory outcome by the patient if proper patient selection is performed.<\/jats:p>\n            <jats:p>\n              <jats:bold>\n                [\n                <jats:italic>J Refract Surg<\/jats:italic>\n                . 2021;37(4):256\u2013262.]\n              <\/jats:bold>\n            <\/jats:p>\n          <\/jats:sec>","DOI":"10.3928\/1081597x-20210209-01","type":"journal-article","created":{"date-parts":[[2021,4,14]],"date-time":"2021-04-14T20:06:33Z","timestamp":1618430793000},"page":"256-262","source":"Crossref","is-referenced-by-count":31,"title":["Clinical Outcomes With a New Continuous Range of Vision Presbyopia-Correcting Intraocular Lens"],"prefix":"10.3928","volume":"37","author":[{"given":"Nikica","family":"Gabri\u0107","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ivan","family":"Gabri\u0107","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kre\u0161imir","family":"Gabri\u0107","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alma","family":"Bi\u0161\u010devi\u0107","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"David P.","family":"Pi\u00f1ero","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Maja","family":"Boha\u010d","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"2308","reference":[{"key":"e_1_3_2_2_2","doi-asserted-by":"publisher","DOI":"10.1186\/s12886-019-1204-0"},{"issue":"6","key":"e_1_3_2_3_2","first-page":"CD012648","article-title":"Trifocal intraocular lenses versus bifocal intraocular lenses after cataract extraction among participants with presbyopia","author":"Zamora-de La Cruz D","year":"2020","unstructured":"Zamora-de La Cruz D, Z\u00fa\u00f1iga-Posselt K, Bartlett J, Gutierrez M, Abariga SA. Trifocal intraocular lenses versus bifocal intraocular lenses after cataract extraction among participants with presbyopia. Cochrane Database Syst Rev. 2020;6:CD012648.","journal-title":"Cochrane Database Syst Rev"},{"key":"e_1_3_2_4_2","doi-asserted-by":"publisher","DOI":"10.1097\/j.jcrs.0000000000000212"},{"key":"e_1_3_2_5_2","doi-asserted-by":"publisher","DOI":"10.1007\/s10792-019-01186-6"},{"key":"e_1_3_2_6_2","doi-asserted-by":"publisher","DOI":"10.1097\/OPX.0b013e3182956c32"},{"key":"e_1_3_2_7_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2008.11.038"},{"key":"e_1_3_2_8_2","doi-asserted-by":"publisher","DOI":"10.1097\/j.jcrs.0000000000000037"},{"key":"e_1_3_2_9_2","doi-asserted-by":"publisher","DOI":"10.1097\/j.jcrs.0000000000000215"},{"key":"e_1_3_2_10_2","doi-asserted-by":"publisher","DOI":"10.1177\/1120672119827858"},{"key":"e_1_3_2_11_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2011.06.008"},{"key":"e_1_3_2_12_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20170302-01"},{"key":"e_1_3_2_13_2","doi-asserted-by":"publisher","DOI":"10.1007\/s10792-019-01196-4"},{"key":"e_1_3_2_14_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.optom.2018.10.003"},{"key":"e_1_3_2_15_2","doi-asserted-by":"publisher","DOI":"10.1097\/j.jcrs.0000000000000210"},{"key":"e_1_3_2_16_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20190306-01"},{"key":"e_1_3_2_17_2","doi-asserted-by":"publisher","DOI":"10.1097\/ICL.0000000000000314"},{"key":"e_1_3_2_18_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20180530-02"},{"key":"e_1_3_2_19_2","doi-asserted-by":"publisher","DOI":"10.1080\/02713683.2018.1478981"},{"key":"e_1_3_2_20_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2017.11.011"},{"key":"e_1_3_2_21_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20180125-01"},{"key":"e_1_3_2_22_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2018.06.048"},{"key":"e_1_3_2_23_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2012.05.032"},{"key":"e_1_3_2_24_2","doi-asserted-by":"publisher","DOI":"10.1177\/1120672118766809"},{"key":"e_1_3_2_25_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2015.04.030"},{"key":"e_1_3_2_26_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2014.05.048"},{"key":"e_1_3_2_27_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2014.11.050"},{"key":"e_1_3_2_28_2","doi-asserted-by":"publisher","DOI":"10.1177\/1120672118762231"},{"key":"e_1_3_2_29_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2015.08.011"},{"key":"e_1_3_2_30_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2013.06.034"},{"key":"e_1_3_2_31_2","article-title":"Characterization of working and mobile phone usage distances in common users of electronic devices and computers","author":"Soler F","unstructured":"Soler F, S\u00e1nchez-Garc\u00eda A, Molina-Martin A, de Fez D, D\u00edaz V, Pi\u00f1ero DP. Characterization of working and mobile phone usage distances in common users of electronic devices and computers. Int J Ophthalmol. In press.","journal-title":"Int J Ophthalmol"},{"key":"e_1_3_2_32_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2012.11.028"},{"key":"e_1_3_2_33_2","doi-asserted-by":"publisher","DOI":"10.1038\/sj.eye.6702661"},{"issue":"10","key":"e_1_3_2_34_2","first-page":"1528","article-title":"Postoperative visual performance with a bifocal and trifocal diffractive intraocular lens during a 1-year follow-up","volume":"10","author":"Mojzis P","year":"2017","unstructured":"Mojzis P, Kukuckova L, Majerova K, Ziak P, Pi\u00f1ero DP. Postoperative visual performance with a bifocal and trifocal diffractive intraocular lens during a 1-year follow-up. Int J Ophthalmol. 2017;10(10):1528\u20131533.","journal-title":"Int J Ophthalmol"},{"key":"e_1_3_2_35_2","doi-asserted-by":"publisher","DOI":"10.1097\/j.jcrs.0000000000000108"},{"key":"e_1_3_2_36_2","doi-asserted-by":"publisher","DOI":"10.1136\/bmjophth-2016-000064"},{"key":"e_1_3_2_37_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2014.10.002"},{"key":"e_1_3_2_38_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2011.05.045"}],"container-title":["Journal of Refractive Surgery"],"original-title":[],"language":"en","deposited":{"date-parts":[[2023,5,3]],"date-time":"2023-05-03T03:29:22Z","timestamp":1683084562000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.healio.com\/doi\/10.3928\/1081597X-20210209-01"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,4]]},"references-count":37,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2021,4]]}},"alternative-id":["10.3928\/1081597X-20210209-01"],"URL":"https:\/\/doi.org\/10.3928\/1081597x-20210209-01","relation":{},"ISSN":["1081-597X"],"issn-type":[{"value":"1081-597X","type":"print"}],"subject":[],"published":{"date-parts":[[2021,4]]}}}