{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,25]],"date-time":"2026-02-25T21:21:48Z","timestamp":1772054508962,"version":"3.50.1"},"reference-count":30,"publisher":"SLACK, Inc.","issue":"10","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Refract Surg"],"published-print":{"date-parts":[[2021,10]]},"abstract":"<jats:sec>\n            <jats:title>PURPOSE:<\/jats:title>\n            <jats:p>To analyze the clinical outcomes obtained with asymmetric intracorneal corneal ring segments (ICRS) of variable thickness and width in patients with keratoconus, identifying predictive parameters of the final visual outcome.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>METHODS:<\/jats:title>\n            <jats:p>This prospective, longitudinal, non-comparative clinical trial enrolled 35 eyes of 27 patients with keratoconus with a significant difference among corneal topographic and comatic axes. All eyes underwent implantation of AJL-pro+ ICRS (AJL Ophthalmic). Visual, refractive, corneal topographic and aberrometric, and pachymetric changes were evaluated during a 3-month follow-up.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>RESULTS:<\/jats:title>\n            <jats:p>\n              Significant changes were detected at 3 months after surgery in manifest sphere and cylinder, spherical equivalent, overall blur strength, and corrected distance visual acuity (CDVA) (\n              <jats:italic>P<\/jats:italic>\n              &lt; .001). No losses of two or more lines of CDVA were observed, whereas 94.3% (33) of eyes gained one or more lines of CDVA. Keratometric readings and the magnitude of anterior corneal astigmatism were significantly reduced with surgery (\n              <jats:italic>P<\/jats:italic>\n              &lt; .001), as well as the levels of corneal coma (\n              <jats:italic>P<\/jats:italic>\n              &lt; .001) and spherical aberration (\n              <jats:italic>P<\/jats:italic>\n              = .007). Likewise, a significant change toward less prolateness was observed (\n              <jats:italic>P<\/jats:italic>\n              &lt; .001). Significant correlations were found among the change in CDVA and preoperative CDVA (\n              <jats:italic>r<\/jats:italic>\n              = \u22120.532,\n              <jats:italic>P<\/jats:italic>\n              = .001), and between the change in primary coma root mean square and the preoperative level of spherical aberration (\n              <jats:italic>r<\/jats:italic>\n              = \u22120.542,\n              <jats:italic>P<\/jats:italic>\n              = .001) and coma root mean square (\n              <jats:italic>r<\/jats:italic>\n              = \u22120.719,\n              <jats:italic>P<\/jats:italic>\n              &lt; .001).\n            <\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>CONCLUSIONS:<\/jats:title>\n            <jats:p>The implantation of the ICRS evaluated in keratoconus with no coincidence between topographic and comatic axes regularizes the corneal shape and reduces the level of higher order aberrations, inducing a significant visual improvement.<\/jats:p>\n            <jats:p>\n              <jats:bold>\n                [\n                <jats:italic>J Refract Surg<\/jats:italic>\n                . 2021;37(10):693\u2013699.]\n              <\/jats:bold>\n            <\/jats:p>\n          <\/jats:sec>","DOI":"10.3928\/1081597x-20210712-04","type":"journal-article","created":{"date-parts":[[2021,10,18]],"date-time":"2021-10-18T21:07:11Z","timestamp":1634591231000},"page":"693-699","source":"Crossref","is-referenced-by-count":15,"title":["Clinical Outcomes of Femtosecond Laser\u2013Assisted Implantation of Asymmetric ICRS in Keratoconus With No Coincidence of Topographic and Comatic Axes"],"prefix":"10.3928","volume":"37","author":[{"given":"Haikel","family":"Kammoun","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"David P.","family":"Pi\u00f1ero","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Juan","family":"\u00c1lvarez de Toledo","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Rafael I.","family":"Barraquer","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Gonzalo","family":"Garc\u00eda de Oteyza","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"2308","reference":[{"key":"e_1_3_2_2_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.joco.2017.11.002"},{"key":"e_1_3_2_3_2","doi-asserted-by":"publisher","DOI":"10.1007\/s40123-019-00211-2"},{"key":"e_1_3_2_4_2","doi-asserted-by":"publisher","DOI":"10.1186\/s40662-016-0040-z"},{"key":"e_1_3_2_5_2","doi-asserted-by":"publisher","DOI":"10.1097\/ICO.0000000000001339"},{"key":"e_1_3_2_6_2","first-page":"4058026","article-title":"Long-term follow-up of intrastromal corneal ring segments in paracentral keratoconus with coincident corneal keratometric, comatic, and refractive axes: stability of the procedure","volume":"2017","author":"Fern\u00e1ndez-Vega Cueto L","year":"2017","unstructured":"Fern\u00e1ndez-Vega Cueto L, Lisa C, Madrid-Costa D, Merayo-Lloves J, Alfonso JF. Long-term follow-up of intrastromal corneal ring segments in paracentral keratoconus with coincident corneal keratometric, comatic, and refractive axes: stability of the procedure. J Ophthalmol. 2017;2017:4058026.28948045","journal-title":"J Ophthalmol"},{"key":"e_1_3_2_7_2","doi-asserted-by":"publisher","DOI":"10.1167\/tvst.8.3.38"},{"key":"e_1_3_2_8_2","doi-asserted-by":"publisher","DOI":"10.1097\/ICU.0000000000000582"},{"key":"e_1_3_2_9_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20191010-02"},{"key":"e_1_3_2_10_2","doi-asserted-by":"publisher","DOI":"10.1097\/ICO.0000000000001449"},{"key":"e_1_3_2_11_2","doi-asserted-by":"publisher","DOI":"10.1097\/ICO.0000000000001075"},{"key":"e_1_3_2_12_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20161027-02"},{"key":"e_1_3_2_13_2","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.09-5017"},{"key":"e_1_3_2_14_2","doi-asserted-by":"publisher","DOI":"10.1097\/ICO.0000000000002160"},{"key":"e_1_3_2_15_2","doi-asserted-by":"publisher","DOI":"10.1097\/ICO.0000000000002062"},{"key":"e_1_3_2_16_2","doi-asserted-by":"publisher","DOI":"10.1097\/ICO.0000000000001709"},{"key":"e_1_3_2_17_2","doi-asserted-by":"publisher","DOI":"10.1007\/s10792-016-0385-2"},{"key":"e_1_3_2_18_2","doi-asserted-by":"publisher","DOI":"10.1097\/j.jcrs.0000000000000525"},{"key":"e_1_3_2_19_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2012.10.022"},{"key":"e_1_3_2_20_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2010.10.046"},{"key":"e_1_3_2_21_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(00)00797-5"},{"key":"e_1_3_2_22_2","first-page":"165","volume-title":"Monograf\u00edas SECOIR","author":"Alfonso JF","year":"2014","unstructured":"Alfonso JF. Clasificaci\u00f3n del queratocono basada en fenotipos cl\u00ednicos. Influencia del astigmatismo congenito en la morfolog\u00eda del queratocono. In: del Buey Sayas A, Peris Mart\u00ednez C, eds. Monograf\u00edas SECOIR. Elsevier Espa\u00f1a, Barcelona, Biomec\u00e1nica y arquitectura corneal. 2014:165\u2013184."},{"key":"e_1_3_2_23_2","doi-asserted-by":"publisher","DOI":"10.1097\/ICO.0b013e3182904950"},{"key":"e_1_3_2_24_2","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-018-36668-7"},{"key":"e_1_3_2_25_2","doi-asserted-by":"publisher","DOI":"10.1177\/11206721211001722"},{"issue":"8","key":"e_1_3_2_26_2","first-page":"1303","article-title":"Effect of intracorneal ring segment implantation on corneal asphericity","volume":"11","author":"Utine CA","year":"2018","unstructured":"Utine CA, Ayhan Z, Durmaz Engin C. Effect of intracorneal ring segment implantation on corneal asphericity. Int J Ophthalmol. 2018;11(8):1303\u20131307.30140633","journal-title":"Int J Ophthalmol"},{"key":"e_1_3_2_27_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20130318-06"},{"key":"e_1_3_2_28_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2012.08.020"},{"key":"e_1_3_2_29_2","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.13-12401"},{"key":"e_1_3_2_30_2","doi-asserted-by":"publisher","DOI":"10.1038\/eye.2017.13"},{"key":"e_1_3_2_31_2","doi-asserted-by":"publisher","DOI":"10.2147\/OPTH.S23147"}],"container-title":["Journal of Refractive Surgery"],"original-title":[],"language":"en","deposited":{"date-parts":[[2023,5,3]],"date-time":"2023-05-03T05:26:56Z","timestamp":1683091616000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.healio.com\/doi\/10.3928\/1081597X-20210712-04"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,10]]},"references-count":30,"journal-issue":{"issue":"10","published-print":{"date-parts":[[2021,10]]}},"alternative-id":["10.3928\/1081597X-20210712-04"],"URL":"https:\/\/doi.org\/10.3928\/1081597x-20210712-04","relation":{},"ISSN":["1081-597X"],"issn-type":[{"value":"1081-597X","type":"print"}],"subject":[],"published":{"date-parts":[[2021,10]]}}}