{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,29]],"date-time":"2026-06-29T10:47:53Z","timestamp":1782730073611,"version":"3.54.5"},"reference-count":26,"publisher":"SLACK, Inc.","issue":"11","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Refract Surg"],"published-print":{"date-parts":[[2021,11]]},"abstract":"<jats:sec>\n                    <jats:title>PURPOSE:<\/jats:title>\n                    <jats:p>To assess the impact of the use of artificial tears during the preoperative work-up performed before age-related cataract surgery, when a toric intraocular lens (IOL) was indicated.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>METHODS:<\/jats:title>\n                    <jats:p>This was a monocentric prospective study assessing 73 eyes of 51 patients, included consecutively after a preoperative work-up performed without artificial tears (no artificial tears group), when a toric IOL was indicated. Each included patient underwent a second series of examinations: biometry using the IOLMaster 700 (Carl Zeiss Meditec AG) and topography using the OPD-Scan II (Nidek), 1 minute after artificial tears instillation (artificial tears group; hyaluronate de sodium 0.15%, threalose 3% [Th\u00e9alose; Th\u00e9a]). Changes in anterior corneal astigmatism and subsequent changes in toric IOL calculation were analyzed. The error in predicted residual astigmatism was calculated.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>RESULTS:<\/jats:title>\n                    <jats:p>\n                      Anterior corneal astigmatism and total corneal astigmatism measured with the IOLMaster 700 were significantly modified when artificial tears were instilled before the examinations (1.51 \u00b1 0.57 diopters [D], range: 0.75 to \u22123.55 vs 1.42 \u00b1 0.63 D, range: 0.42 to 3.35 D;\n                      <jats:italic>P<\/jats:italic>\n                      = .043 and 1.59 \u00b1 0.54 D, range: 0.87 to 3.48 vs 1.51 \u00b1 0.59 D, range: 0.56 to 3.27 D,\n                      <jats:italic>P<\/jats:italic>\n                      = .038, respectively). This modification led to a change in IOL cylinder calculation in 43.8% of cases and to a change in implantation axis greater than 10\u00b0 in 17.7% of cases. These changes were significantly greater in patients with a breakup time (BUT) less than 5 seconds (57.5% and 27.8%, with\n                      <jats:italic>P<\/jats:italic>\n                      = .009 and .029, respectively). In the subgroup of patients with a BUT of less than 5 seconds, the mean absolute error in predicted astigmatism was significantly lower after artificial tears instillation (0.48 \u00b1 0.50 D, range: 0.00 to 2.79 vs 0.37 \u00b1 0.25 D, range: 0.00 to 1.10 D,\n                      <jats:italic>P<\/jats:italic>\n                      = .048).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>CONCLUSIONS:<\/jats:title>\n                    <jats:p>Dry eye significantly impacted toric IOL calculations and should be taken into account during the preoperative assessments. Using artificial tears reduced the number of refractive errors.<\/jats:p>\n                    <jats:p>\n                      <jats:bold>\n                        [\n                        <jats:italic>J Refract Surg<\/jats:italic>\n                        . 2021;37(11):759\u2013766.]\n                      <\/jats:bold>\n                    <\/jats:p>\n                  <\/jats:sec>","DOI":"10.3928\/1081597x-20210826-01","type":"journal-article","created":{"date-parts":[[2021,11,10]],"date-time":"2021-11-10T08:53:39Z","timestamp":1636534419000},"page":"759-766","source":"Crossref","is-referenced-by-count":20,"title":["Should Artificial Tears Be Used During the Preoperative Assessment of Toric IOLs Before Age-Related Cataract Surgery? The TORIDE Study"],"prefix":"10.3928","volume":"37","author":[{"given":"Elsa","family":"Rochet","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Antoine","family":"Levron","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Emilie","family":"Agard","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hussam El","family":"Chehab","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"H\u00e9l\u00e8ne","family":"Plas","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hugo","family":"Bouvarel","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nicolas","family":"Chirpaz","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"J\u00e9r\u00e9my","family":"Billant","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Corinne","family":"Dot","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"2308","reference":[{"key":"e_1_3_2_2_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2011.02.024"},{"key":"e_1_3_2_3_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jfo.2017.11.002"},{"key":"e_1_3_2_4_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20140723-01"},{"key":"e_1_3_2_5_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2011.04.036"},{"issue":"9","key":"e_1_3_2_6_2","first-page":"1276","article-title":"Effects of posterior corneal astigmatism on the accuracy of AcrySof toric intraocular lens astigmatism correction","volume":"9","author":"Zhang B","year":"2016","unstructured":"Zhang B, Ma J-X, Liu D-Y. Effects of posterior corneal astigmatism on the accuracy of AcrySof toric intraocular lens astigmatism correction. Int J Ophthalmol. 2016;9(9):1276\u20131282. doi:27672591","journal-title":"Int J Ophthalmol"},{"key":"e_1_3_2_7_2","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.14-15903"},{"key":"e_1_3_2_8_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.optm.2010.07.025"},{"key":"e_1_3_2_9_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0161-6420(02)01136-3"},{"key":"e_1_3_2_10_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0161-6420(99)00513-8"},{"key":"e_1_3_2_11_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0161-6420(03)00245-8"},{"key":"e_1_3_2_12_2","doi-asserted-by":"publisher","DOI":"10.2147\/OPTH.S120159"},{"key":"e_1_3_2_13_2","doi-asserted-by":"publisher","DOI":"10.1097\/IIO.0b013e31820f1f76"},{"key":"e_1_3_2_14_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jfo.2013.03.006"},{"key":"e_1_3_2_15_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(00)00796-3"},{"key":"e_1_3_2_16_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(00)00798-7"},{"key":"e_1_3_2_17_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(13)80617-7"},{"key":"e_1_3_2_18_2","doi-asserted-by":"publisher","DOI":"10.1136\/bjo.2008.151829"},{"key":"e_1_3_2_19_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00417-020-05046-3"},{"key":"e_1_3_2_20_2","doi-asserted-by":"publisher","DOI":"10.1097\/ICL.0000000000000552"},{"key":"e_1_3_2_21_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2015.01.016"},{"key":"e_1_3_2_22_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2010.10.032"},{"key":"e_1_3_2_23_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jtos.2013.07.003"},{"key":"e_1_3_2_24_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2017.10.050"},{"key":"e_1_3_2_25_2","doi-asserted-by":"publisher","DOI":"10.3390\/biom10050809"},{"key":"e_1_3_2_26_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2007.06.019"},{"key":"e_1_3_2_27_2","doi-asserted-by":"publisher","DOI":"10.1111\/aos.14408"}],"container-title":["Journal of Refractive Surgery"],"original-title":[],"language":"en","deposited":{"date-parts":[[2023,5,3]],"date-time":"2023-05-03T09:12:45Z","timestamp":1683105165000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.healio.com\/doi\/10.3928\/1081597X-20210826-01"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,11]]},"references-count":26,"journal-issue":{"issue":"11","published-print":{"date-parts":[[2021,11]]}},"alternative-id":["10.3928\/1081597X-20210826-01"],"URL":"https:\/\/doi.org\/10.3928\/1081597x-20210826-01","relation":{"has-review":[{"id-type":"doi","id":"10.3410\/f.741146465.793590214","asserted-by":"object"}]},"ISSN":["1081-597X"],"issn-type":[{"value":"1081-597X","type":"print"}],"subject":[],"published":{"date-parts":[[2021,11]]}}}