{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,18]],"date-time":"2026-08-18T05:25:44Z","timestamp":1787030744798,"version":"build-2736575974"},"reference-count":26,"publisher":"SLACK, Inc.","issue":"4","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Refract Surg"],"published-print":{"date-parts":[[2022,4]]},"abstract":"<jats:sec>\n                    <jats:title>PURPOSE:<\/jats:title>\n                    <jats:p>To evaluate the effect of the implantation of intracorneal ring segments (ICRS) in keratoconus on the dynamic corneal response (DCR) parameters obtained with the Corvis ST (Oculus Optikger\u00e4te GmbH).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>METHODS:<\/jats:title>\n                    <jats:p>This prospective clinical study included patients who underwent ICRS implantation for keratoconus over a period of 1 year. On the day of the surgery and at least 1 month after ICRS implantation, the following measurements were made: corrected and uncorrected distance visual acuity, corneal tomography indices with the Pentacam (Oculus Optikger\u00e4te GmbH), biomechanically corrected intraocular pressure (bIOP), Corvis ST DCR parameters, integrated inverse concave radius (1\/R), deformation amplitude ratio (DA ratio), stiffness parameter at first applanation (SP-A1), stress\u2013strain index (SSI), and highest concavity radius (HRC).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>RESULTS:<\/jats:title>\n                    <jats:p>\n                      Fifty-one eyes of 40 patients were included with a median follow-up time of 3 months (interquartile ratio [IQR]: 2 to 6 months). Statistical analysis showed that ICRS implantation did not affect corneal biomechanical measurements evaluated with the Corvis ST, which was demonstrated by non-significant changes in the SP-A1 (\n                      <jats:italic>P<\/jats:italic>\n                      = .637), 1\/R (\n                      <jats:italic>P<\/jats:italic>\n                      = .647), HRC (\n                      <jats:italic>P<\/jats:italic>\n                      = .177), DA ratio (\n                      <jats:italic>P<\/jats:italic>\n                      = .735), and SSI (\n                      <jats:italic>P<\/jats:italic>\n                      = .501). Additionally, the results showed that bIOP measurements were not significantly affected by ICRS implantation (\n                      <jats:italic>P<\/jats:italic>\n                      = .113).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>CONCLUSIONS:<\/jats:title>\n                    <jats:p>ICRS implantation does not affect corneal biomechanical measurements in early follow-up.<\/jats:p>\n                    <jats:p>\n                      <jats:bold>\n                        [\n                        <jats:italic>J Refract Surg<\/jats:italic>\n                        . 2022;38(4):264\u2013269.]\n                      <\/jats:bold>\n                    <\/jats:p>\n                  <\/jats:sec>","DOI":"10.3928\/1081597x-20220202-01","type":"journal-article","created":{"date-parts":[[2022,4,12]],"date-time":"2022-04-12T12:43:07Z","timestamp":1649767387000},"page":"264-269","source":"Crossref","is-referenced-by-count":13,"title":["The Effect of Intracorneal Ring Segments Implantation for Keratoconus on In Vivo Corneal Biomechanics Assessed With the Corvis ST"],"prefix":"10.3928","volume":"38","author":[{"given":"Riccardo","family":"Vinciguerra","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Luis","family":"Fern\u00e1ndez-Vega-Cueto","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Arancha","family":"Poo-Lopez","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ashkan","family":"Eliasy","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jes\u00fas","family":"Merayo-Lloves","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ahmed","family":"Elsheikh","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"David","family":"Madrid-Costa","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Carlos","family":"Lisa","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jos\u00e9 F.","family":"Alfonso","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"2308","reference":[{"key":"e_1_3_2_2_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0039-6257(97)00119-7"},{"key":"e_1_3_2_3_2","doi-asserted-by":"publisher","DOI":"10.5005\/jp\/books\/11483_5"},{"key":"e_1_3_2_4_2","doi-asserted-by":"publisher","DOI":"10.1097\/ICO.0000000000002283"},{"key":"e_1_3_2_5_2","first-page":"4058026","article-title":"Long-term follow-up of intrastromal corneal ring segments in paracentral keratoconus with coincident corneal keratometric, comatic, and refractive axes: stability of the procedure","volume":"2017","author":"Fern\u00e1ndez-Vega Cueto L","year":"2017","unstructured":"Fern\u00e1ndez-Vega Cueto L, Lisa C, Madrid-Costa D, Merayo-Lloves J, Alfonso JF. Long-term follow-up of intrastromal corneal ring segments in paracentral keratoconus with coincident corneal keratometric, comatic, and refractive axes: stability of the procedure. J Ophthalmol. 2017;2017:4058026. PMID:28948045","journal-title":"J Ophthalmol"},{"key":"e_1_3_2_6_2","doi-asserted-by":"publisher","DOI":"10.1097\/ICO.0000000000000978"},{"key":"e_1_3_2_7_2","doi-asserted-by":"publisher","DOI":"10.1155\/2017\/7589816"},{"key":"e_1_3_2_8_2","doi-asserted-by":"publisher","DOI":"10.1097\/ICO.0000000000001339"},{"key":"e_1_3_2_9_2","doi-asserted-by":"publisher","DOI":"10.3928\/01913913-20210719-02"},{"key":"e_1_3_2_10_2","doi-asserted-by":"publisher","DOI":"10.1097\/ICO.0000000000001945"},{"key":"e_1_3_2_11_2","first-page":"112067212095234","article-title":"Intrastromal corneal ring segment implantation in paracentral keratoconus with perpendicular topographic astigmatism and comatic axis","author":"Fernandez-Vega-Cueto L","year":"2020","unstructured":"Fernandez-Vega-Cueto L, Lisa C, Alfonso-Bartolozzi B, Madrid-Costa D, Alfonso JF. Intrastromal corneal ring segment implantation in paracentral keratoconus with perpendicular topographic astigmatism and comatic axis. Eur J Ophthalmol. 2020:1120672120952346. PMID:32830575","journal-title":"Eur J Ophthalmol"},{"key":"e_1_3_2_12_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20201123-03"},{"key":"e_1_3_2_13_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jfo.2020.03.019"},{"key":"e_1_3_2_14_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2014.04.013"},{"key":"e_1_3_2_15_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2004.10.044"},{"key":"e_1_3_2_16_2","doi-asserted-by":"publisher","DOI":"10.1097\/ICO.0b013e31821ee9f4"},{"key":"e_1_3_2_17_2","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.11-8281"},{"key":"e_1_3_2_18_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20160524-01"},{"key":"e_1_3_2_19_2","first-page":"2390","article-title":"New stiffness parameter in air puff induced corneal deformation analysis","volume":"57","author":"Roberts CJ","year":"2016","unstructured":"Roberts CJ, Mahmoud AM, Bons J, . New stiffness parameter in air puff induced corneal deformation analysis. Invest Ophth Vis Sci. 2016;57:2390. https:\/\/iovs.arvojournals.org\/article.aspx?articleid=2558046","journal-title":"Invest Ophth Vis Sci"},{"key":"e_1_3_2_20_2","doi-asserted-by":"publisher","DOI":"10.3389\/fbioe.2019.00105"},{"key":"e_1_3_2_21_2","doi-asserted-by":"publisher","DOI":"10.1080\/10255842.2015.1077515"},{"key":"e_1_3_2_22_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20160629-01"},{"key":"e_1_3_2_23_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20170426-02"},{"key":"e_1_3_2_24_2","doi-asserted-by":"publisher","DOI":"10.1111\/aos.15044"},{"key":"e_1_3_2_25_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20161221-03"},{"key":"e_1_3_2_26_2","doi-asserted-by":"publisher","DOI":"10.1155\/2020\/4274037"},{"key":"e_1_3_2_27_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2009.05.033"}],"container-title":["Journal of Refractive Surgery"],"original-title":[],"language":"en","deposited":{"date-parts":[[2023,5,3]],"date-time":"2023-05-03T07:38:03Z","timestamp":1683099483000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.healio.com\/doi\/10.3928\/1081597X-20220202-01"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,4]]},"references-count":26,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2022,4]]}},"alternative-id":["10.3928\/1081597X-20220202-01"],"URL":"https:\/\/doi.org\/10.3928\/1081597x-20220202-01","relation":{},"ISSN":["1081-597X"],"issn-type":[{"value":"1081-597X","type":"print"}],"subject":[],"published":{"date-parts":[[2022,4]]}}}