{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,24]],"date-time":"2026-10-24T06:06:34Z","timestamp":1792821994766,"version":"4.5.0"},"reference-count":31,"publisher":"SLACK, Inc.","issue":"6","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Refract Surg"],"published-print":{"date-parts":[[2022,6]]},"abstract":"<jats:sec>\n                    <jats:title>PURPOSE:<\/jats:title>\n                    <jats:p>To compare visual, refractive, and safety outcomes of toric posterior chamber Implantable Collamer Lens (T-ICL) (STAAR Surgical) and toric iris-fixated foldable phakic intraocular lens (IOL) (T-Artiflex; Ophtec BV) implantation for the correction of myopic astigmatism.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>METHODS:<\/jats:title>\n                    <jats:p>This retrospective cohort study included 312 eyes of 312 patients who had phakic IOL implantation for myopic astigmatism. Two groups were defined: 205 eyes that underwent T-ICL implantation and 107 eyes that underwent T-Artiflex implantation. Safety, efficacy, and predictability outcomes were evaluated preoperatively and at 12 months postoperatively. Refractive and corneal astigmatic vector analysis were performed using the Alpins method.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>RESULTS:<\/jats:title>\n                    <jats:p>\n                      One year postoperatively, uncorrected distance visual acuity was 0.05 \u00b1 0.18 (T-ICL) and 0.10 \u00b1 0.16 (T-Artiflex) logMAR, with efficacy indexes of 1.16 \u00b1 0.27 and 1.05 \u00b1 0.31, respectively (\n                      <jats:italic>P<\/jats:italic>\n                      &lt; .001). Safety indexes were 1.28 \u00b1 0.30 and 1.21 \u00b1 0.31, respectively (\n                      <jats:italic>P<\/jats:italic>\n                      = .04). Spherical equivalent was within \u00b10.50 diopters (D) of emmetropia in 165 (80.5%) and 88 (82.2%) eyes, respectively. Refractive astigmatic analysis showed an index of success of 0.28 \u00b1 0.33 (T-ICL) and 0.31 \u00b1 0.26 (T-Artiflex) (\n                      <jats:italic>P<\/jats:italic>\n                      = .07). Surgically induced corneal astigmatism was 0.48 \u00b1 0.74 and 0.81 \u00b1 0.61 D, respectively (\n                      <jats:italic>P<\/jats:italic>\n                      &lt; .001). Mean endothelial loss was 1.11% and 2.05%, respectively (\n                      <jats:italic>P<\/jats:italic>\n                      = .42). Six (2.9%) eyes in the T-ICL group and 1 (0.9%) eye in the T-Artiflex group had phakic IOL repositioning due to significant misalignment. No vision-threatening complications occurred.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>CONCLUSIONS:<\/jats:title>\n                    <jats:p>Both the T-ICL and T-Artiflex groups showed high visual and refractive efficacy with a good safety profile for the correction of myopic astigmatism. T-ICL implantation demonstrated significantly better efficacy and safety indexes after 12 months. Vector analysis showed similar refractive astigmatic correction in both groups, but T-Artiflex implantation revealed higher surgically induced corneal astigmatism.<\/jats:p>\n                    <jats:p>\n                      <jats:bold>\n                        [\n                        <jats:italic>J Refract Surg<\/jats:italic>\n                        . 2022;38(6):339\u2013347.]\n                      <\/jats:bold>\n                    <\/jats:p>\n                  <\/jats:sec>","DOI":"10.3928\/1081597x-20220406-01","type":"journal-article","created":{"date-parts":[[2022,6,10]],"date-time":"2022-06-10T07:23:01Z","timestamp":1654845781000},"page":"339-347","source":"Crossref","is-referenced-by-count":17,"title":["Efficacy and Safety After Toric Posterior Chamber Implantable Collamer Lens and Toric Iris-Fixated Foldable Phakic Intraocular Lens for Myopic Astigmatism"],"prefix":"10.3928","volume":"38","author":[{"given":"Tiago","family":"Monteiro","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christophe","family":"Pinto","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nuno","family":"Franqueira","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fernando","family":"Faria-Correia","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jos\u00e9","family":"Mendes","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jos\u00e9","family":"Alfonso S\u00e1nchez","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fernando","family":"Vaz","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"2308","reference":[{"key":"e_1_3_2_2_2","doi-asserted-by":"publisher","DOI":"10.1186\/s40662-021-00247-1"},{"key":"e_1_3_2_3_2","doi-asserted-by":"publisher","DOI":"10.2147\/OPTH.S188785"},{"key":"e_1_3_2_4_2","doi-asserted-by":"publisher","DOI":"10.1097\/j.jcrs.0000000000000419"},{"key":"e_1_3_2_5_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2018.07.015"},{"key":"e_1_3_2_6_2","doi-asserted-by":"publisher","DOI":"10.1097\/j.jcrs.0000000000000786"},{"key":"e_1_3_2_7_2","doi-asserted-by":"publisher","DOI":"10.1097\/j.jcrs.0000000000000560"},{"key":"e_1_3_2_8_2","doi-asserted-by":"publisher","DOI":"10.4103\/ijo.IJO_1501_18"},{"key":"e_1_3_2_9_2","doi-asserted-by":"publisher","DOI":"10.5301\/ejo.5000298"},{"key":"e_1_3_2_10_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2011.11.027"},{"key":"e_1_3_2_11_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2012.02.034"},{"key":"e_1_3_2_12_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2010.02.022"},{"key":"e_1_3_2_13_2","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0056453"},{"key":"e_1_3_2_14_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2011.11.028"},{"key":"e_1_3_2_15_2","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.11-8868"},{"key":"e_1_3_2_16_2","doi-asserted-by":"publisher","DOI":"10.1177\/1120672121999991"},{"key":"e_1_3_2_17_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2020.06.021"},{"key":"e_1_3_2_18_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(97)80021-1"},{"key":"e_1_3_2_19_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.survophthal.2003.10.010"},{"key":"e_1_3_2_20_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2019.03.009"},{"key":"e_1_3_2_21_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2010.08.014"},{"key":"e_1_3_2_22_2","article-title":"Posterior chamber collamer phakic intraocular lens implantation: comparison of efficacy and safety for low and moderate-to-high myopia","author":"Pinto C","unstructured":"Pinto C, Monteiro T, Franqueira N, Faria-Correia F, Mendes J, Vaz F. Posterior chamber collamer phakic intraocular lens implantation: comparison of efficacy and safety for low and moderate-to-high myopia. Eur J Ophthalmol. Published online August 21, 2021. PMID:33887990","journal-title":"Eur J Ophthalmol"},{"key":"e_1_3_2_23_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(00)00798-7"},{"key":"e_1_3_2_24_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2012.04.006"},{"key":"e_1_3_2_25_2","doi-asserted-by":"publisher","DOI":"10.1177\/11206721211035617"},{"key":"e_1_3_2_26_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(01)01098-7"},{"key":"e_1_3_2_27_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2006.08.049"},{"key":"e_1_3_2_28_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2009.10.052"},{"key":"e_1_3_2_29_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00417-010-1540-5"},{"key":"e_1_3_2_30_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2009.08.021"},{"key":"e_1_3_2_31_2","doi-asserted-by":"publisher","DOI":"10.1136\/bjo.2009.160044"},{"key":"e_1_3_2_32_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2008.12.059"}],"container-title":["Journal of Refractive Surgery"],"original-title":[],"language":"en","deposited":{"date-parts":[[2023,5,3]],"date-time":"2023-05-03T04:51:57Z","timestamp":1683089517000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.healio.com\/doi\/10.3928\/1081597X-20220406-01"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,6]]},"references-count":31,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2022,6]]}},"alternative-id":["10.3928\/1081597X-20220406-01"],"URL":"https:\/\/doi.org\/10.3928\/1081597x-20220406-01","relation":{},"ISSN":["1081-597X"],"issn-type":[{"value":"1081-597X","type":"print"}],"subject":[],"published":{"date-parts":[[2022,6]]}}}