{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,18]],"date-time":"2026-11-18T16:39:13Z","timestamp":1795019953412,"version":"4.10.1"},"reference-count":25,"publisher":"SLACK, Inc.","issue":"9","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Refract Surg"],"published-print":{"date-parts":[[2022,9]]},"abstract":"<jats:sec>\n            <jats:title>PURPOSE:<\/jats:title>\n            <jats:p>To compare the functional optical zone (FOZ) in eyes with high myopia with high astigmatism after small incision lenticule extraction (SMILE) and femtosecond laser\u2013assisted laser in situ keratomileusis (FS-LASIK).<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>METHODS:<\/jats:title>\n            <jats:p>In total, 45 eyes of 45 patients with high myopia with astigmatism greater than 2.00 diopters (D) who underwent SMILE or FS-LASIK were enrolled. The FOZ, optical zone decentration, and corneal aberrations were analyzed using Scheimpflug imaging. These values were then compared between the two groups 6 months postoperatively.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>RESULTS:<\/jats:title>\n            <jats:p>\n              No postoperative complications were observed during follow-up. The mean FOZ diameter was 5.03 \u00b1 0.31 mm for the FS-LASIK group and 5.24 \u00b1 0.27 mm for the SMILE group (\n              <jats:italic>P<\/jats:italic>\n              = .007), corresponding to reductions of 1.18 \u00b1 0.23 and 1.01 \u00b1 0.21 mm, respectively, compared with the programmed optical zone (POZ) (\n              <jats:italic>P<\/jats:italic>\n              = .013). A significant difference was noted in the FOZ on the short axis between the two groups (\n              <jats:italic>P<\/jats:italic>\n              = .002), whereas no significant difference was observed on the long axis (\n              <jats:italic>P<\/jats:italic>\n              = .088). The FOZ area in the FS-LASIK and SMILE groups was 65.39 \u00b1 6.14% and 70.09 \u00b1 5.46% of the POZ area, respectively (\n              <jats:italic>P<\/jats:italic>\n              = .010). There was no significant difference in decentration between the two groups (0.29 \u00b1 0.13 mm for the FS-LASIK group vs 0.30 \u00b1 0.13 mm for the SMILE group,\n              <jats:italic>P<\/jats:italic>\n              = .798). A significant increase in spherical aberration was observed in the FS-LASIK group (\n              <jats:italic>P<\/jats:italic>\n              &lt; .001). However, the induction of vertical coma was higher in the SMILE group than in the FS-LASIK group (\n              <jats:italic>P<\/jats:italic>\n              = .002).\n            <\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>CONCLUSIONS:<\/jats:title>\n            <jats:p>Eyes with high myopia with high astigmatism following SMILE achieved a larger FOZ and less spherical aberration but a larger vertical coma introduction than following FS-LASIK.<\/jats:p>\n            <jats:p>\n              <jats:bold>\n                [\n                <jats:italic>J Refract Surg<\/jats:italic>\n                . 2022;38(9):595\u2013601.]\n              <\/jats:bold>\n            <\/jats:p>\n          <\/jats:sec>","DOI":"10.3928\/1081597x-20220725-01","type":"journal-article","created":{"date-parts":[[2022,9,13]],"date-time":"2022-09-13T11:42:57Z","timestamp":1663069377000},"page":"595-601","source":"Crossref","is-referenced-by-count":18,"title":["Comparison of the Functional Optical Zone in Eyes With High Myopia With High Astigmatism After SMILE and FS-LASIK"],"prefix":"10.3928","volume":"38","author":[{"given":"Shengtao","family":"Liu","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xiaoxue","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lingling","family":"Niu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zhiqiang","family":"Yu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xingtao","family":"Zhou","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jing","family":"Zhao","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"2308","reference":[{"issue":"7","key":"e_1_3_2_2_2","first-page":"2275","article-title":"Optical zone diameters for photorefractive corneal surgery","volume":"34","author":"Roberts CW","year":"1993","unstructured":"Roberts CW, Koester CJ. Optical zone diameters for photorefractive corneal surgery. Invest Ophthalmol Vis Sci. 1993;34(7):2275\u20132281. PMID:8505209","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"e_1_3_2_3_2","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.06-0867"},{"key":"e_1_3_2_4_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2004.04.073"},{"key":"e_1_3_2_5_2","doi-asserted-by":"publisher","DOI":"10.1097\/j.jcrs.0000000000000282"},{"key":"e_1_3_2_6_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2010.07.033"},{"key":"e_1_3_2_7_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2012.07.021"},{"key":"e_1_3_2_8_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20140320-02"},{"key":"e_1_3_2_9_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2018.06.046"},{"key":"e_1_3_2_10_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20190313-01"},{"key":"e_1_3_2_11_2","doi-asserted-by":"publisher","DOI":"10.1007\/s40123-021-00330-9"},{"key":"e_1_3_2_12_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20200310-01"},{"key":"e_1_3_2_13_2","doi-asserted-by":"publisher","DOI":"10.1155\/2017\/4921090"},{"key":"e_1_3_2_14_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20150727-03"},{"key":"e_1_3_2_15_2","doi-asserted-by":"publisher","DOI":"10.1097\/ICO.0000000000001669"},{"key":"e_1_3_2_16_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20170111-01"},{"key":"e_1_3_2_17_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20140320-03"},{"key":"e_1_3_2_18_2","doi-asserted-by":"publisher","DOI":"10.1159\/000504304"},{"issue":"3","key":"e_1_3_2_19_2","first-page":"470","article-title":"Three-year results of small incision lenticule extraction and wavefront-guided femtosecond laser-assisted laser in situ keratomileusis for correction of high myopia and myopic astigmatism","volume":"11","author":"Xia LK","year":"2018","unstructured":"Xia LK, Ma J, Liu HN, Shi C, Huang Q. Three-year results of small incision lenticule extraction and wavefront-guided femtosecond laser-assisted laser in situ keratomileusis for correction of high myopia and myopic astigmatism. Int J Ophthalmol. 2018;11(3):470\u2013477. PMID:29600182","journal-title":"Int J Ophthalmol"},{"key":"e_1_3_2_20_2","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.17-23451"},{"key":"e_1_3_2_21_2","doi-asserted-by":"publisher","DOI":"10.1177\/1120672119865688"},{"key":"e_1_3_2_22_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2003.09.039"},{"key":"e_1_3_2_23_2","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.13-13714"},{"key":"e_1_3_2_24_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(02)01324-X"},{"key":"e_1_3_2_25_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.visres.2010.07.014"},{"key":"e_1_3_2_26_2","doi-asserted-by":"publisher","DOI":"10.1167\/11.2.5"}],"container-title":["Journal of Refractive Surgery"],"original-title":[],"language":"en","deposited":{"date-parts":[[2023,5,2]],"date-time":"2023-05-02T16:59:21Z","timestamp":1683046761000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.healio.com\/doi\/10.3928\/1081597X-20220725-01"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,9]]},"references-count":25,"journal-issue":{"issue":"9","published-print":{"date-parts":[[2022,9]]}},"alternative-id":["10.3928\/1081597X-20220725-01"],"URL":"https:\/\/doi.org\/10.3928\/1081597x-20220725-01","relation":{},"ISSN":["1081-597X"],"issn-type":[{"value":"1081-597X","type":"print"}],"subject":[],"published":{"date-parts":[[2022,9]]}}}