{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,14]],"date-time":"2026-11-14T11:07:21Z","timestamp":1794654441900,"version":"4.9.1"},"reference-count":30,"publisher":"SLACK, Inc.","issue":"7","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Refract Surg"],"published-print":{"date-parts":[[2023,7]]},"abstract":"<jats:sec>\n            <jats:title>Purpose:<\/jats:title>\n            <jats:p>To assess repeatability and agreement of corneal epithelial thickness mapping in eyes with keratoconus using three optical coherence tomography (OCT) devices featuring different technologies: spectral-domain (SD) OCT combined with Placido disk corneal topography (MS-39), swept-source OCT (Anterion), and SD-OCT (Avanti).<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods:<\/jats:title>\n            <jats:p>\n              Three consecutive measurements were acquired with the three devices in 60 eyes with keratoconus. The mean epithelial thickness was calculated in the central 2-mm zone and in 2- to 5-mm and 5- to 7-mm diameter rings. The repeatability was calculated using pooled within-subject standard deviation (S\n              <jats:sub>w<\/jats:sub>\n              ). The agreement was assessed by paired\n              <jats:italic>t<\/jats:italic>\n              tests and Bland-Altman plots.\n            <\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>\n              The repeatability (Sw) of the epithelial thickness for the central 2-mm zone was 0.91, 0.71, and 0.93 \u03bcm for the MS-39, Anterion, and Avanti, respectively. All thicknesses with the MS-39 were greater than those of the Anterion and Avanti, with mean differences of 4.11 \u00b1 1.34 \u03bcm (\n              <jats:italic>P<\/jats:italic>\n              &lt; .001) and 0.52 \u00b1 1.30 \u03bcm (\n              <jats:italic>P<\/jats:italic>\n              = .003), respectively. The 95% limits of agreement were 1.484 to 6.736 \u03bcm for the MS-39 and Anterion, \u22123.068 to 2.028 \u03bcm for the Avanti and MS-39, and 1.258 to 5.922 \u03bcm for for the Avanti and Anterion.\n            <\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions:<\/jats:title>\n            <jats:p>Epithelial thickness mapping results were most repeatable with the Anterion, followed by the MS-39 and Avanti. The MS-39 gave the thickest values, followed by the Avanti and Anterion. The differences were significant, making the devices not interchangeable for epithelial thickness mapping in eyes with keratoconus.<\/jats:p>\n            <jats:p>\n              <jats:bold>\n                [\n                <jats:italic>J Refract Surg<\/jats:italic>\n                . 2023;39(7):474\u2013480.]\n              <\/jats:bold>\n            <\/jats:p>\n          <\/jats:sec>","DOI":"10.3928\/1081597x-20230606-01","type":"journal-article","created":{"date-parts":[[2023,7,14]],"date-time":"2023-07-14T09:54:07Z","timestamp":1689328447000},"page":"474-480","source":"Crossref","is-referenced-by-count":25,"title":["Epithelial Thickness Mapping in Keratoconic Corneas: Repeatability and Agreement Between CSO MS-39, Heidelberg Anterion, and Optovue Avanti OCT Devices"],"prefix":"10.3928","volume":"39","author":[{"given":"Yue","family":"Feng","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dan Z.","family":"Reinstein","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tore","family":"Nitter","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Timothy J.","family":"Archer","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Colm","family":"McAlinden","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Geir","family":"Bertelsen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Aleksandar","family":"Stojanovic","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"2308","reference":[{"key":"e_1_3_2_2_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20090610-06"},{"key":"e_1_3_2_3_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20210405-01"},{"key":"e_1_3_2_4_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0161-6420(99)90105-7"},{"key":"e_1_3_2_5_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081-597X-19930101-10"},{"key":"e_1_3_2_6_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081-597X-19930901-12"},{"key":"e_1_3_2_7_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0039-6257(97)00119-7"},{"key":"e_1_3_2_8_2","doi-asserted-by":"publisher","DOI":"10.1080\/02713683.2022.2058020"},{"key":"e_1_3_2_9_2","doi-asserted-by":"publisher","DOI":"10.2147\/OPTH.S31524"},{"key":"e_1_3_2_10_2","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.13-12578"},{"key":"e_1_3_2_11_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2012.06.023"},{"key":"e_1_3_2_12_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20100218-01"},{"key":"e_1_3_2_13_2","doi-asserted-by":"publisher","DOI":"10.1097\/OPX.0b013e318188892c"},{"key":"e_1_3_2_14_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20140508-01"},{"key":"e_1_3_2_15_2","doi-asserted-by":"publisher","DOI":"10.2147\/OPTH.S208101"},{"key":"e_1_3_2_16_2","doi-asserted-by":"publisher","DOI":"10.1136\/bmjophth-2016-000058"},{"key":"e_1_3_2_17_2","doi-asserted-by":"publisher","DOI":"10.1007\/978-3-030-16638-0_13"},{"key":"e_1_3_2_18_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20220414-01"},{"key":"e_1_3_2_19_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2019.01.015"},{"key":"e_1_3_2_20_2","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-020-57926-7"},{"key":"e_1_3_2_21_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2018.02.015"},{"key":"e_1_3_2_22_2","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0085994"},{"key":"e_1_3_2_23_2","doi-asserted-by":"publisher","DOI":"10.1136\/bmj.313.7059.744"},{"key":"e_1_3_2_24_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2015.06.029"},{"key":"e_1_3_2_25_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20091105-01"},{"key":"e_1_3_2_26_2","doi-asserted-by":"publisher","DOI":"10.1097\/ICO.0b013e3182a7f39d"},{"key":"e_1_3_2_27_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2018.09.008"},{"key":"e_1_3_2_28_2","doi-asserted-by":"publisher","DOI":"10.1097\/ICO.0000000000001806"},{"key":"e_1_3_2_29_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20190806-03"},{"key":"e_1_3_2_30_2","first-page":"756","article-title":"Pre-corneal tear film thickness in humans measured with a novel technique","volume":"17","author":"Azartash K","year":"2011","unstructured":"Azartash K, Kwan J, Paugh JR, Nguyen AL, Jester JV, Gratton E. Pre-corneal tear film thickness in humans measured with a novel technique. Mol Vis. 2011;17:756\u2013767. PMID:21527997","journal-title":"Mol Vis"},{"key":"e_1_3_2_31_2","doi-asserted-by":"publisher","DOI":"10.1007\/978-3-030-16638-0_3"}],"container-title":["Journal of Refractive Surgery"],"original-title":[],"language":"en","deposited":{"date-parts":[[2024,1,9]],"date-time":"2024-01-09T11:26:16Z","timestamp":1704799576000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.healio.com\/doi\/10.3928\/1081597X-20230606-01"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,7]]},"references-count":30,"journal-issue":{"issue":"7","published-print":{"date-parts":[[2023,7]]}},"alternative-id":["10.3928\/1081597X-20230606-01"],"URL":"https:\/\/doi.org\/10.3928\/1081597x-20230606-01","relation":{},"ISSN":["1081-597X"],"issn-type":[{"value":"1081-597X","type":"print"}],"subject":[],"published":{"date-parts":[[2023,7]]}}}