{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,23]],"date-time":"2026-06-23T20:48:39Z","timestamp":1782247719280,"version":"3.54.5"},"reference-count":27,"publisher":"SLACK, Inc.","issue":"8","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Refract Surg"],"published-print":{"date-parts":[[2023,8,1]]},"abstract":"<jats:sec>\n                    <jats:title>Purpose:<\/jats:title>\n                    <jats:p>To compare the dynamic vault range (the difference in the central vault height from scotopic to photopic light condition) after implantation of the ICL\/TICL (STAAR Surgical) and Eyecryl phakic\/Eyecryl phakic toric intraocular lens (IOL) (Biotech Healthcare).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>This retrospective study included patients with myopia or myopic astigmatism eligible for phakic IOL implantation with either the ICL\/TICL or Eyecryl phakic\/Eyecryl phakic toric IOL. Vault changes in varying light conditions (scotopic, mesopic, and photopic) were assessed using an anterior segment optical coherence tomography\u2013based tomographer and dynamic vault range (DVR) was compared between the two groups.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      A total of 60 eyes from 36 patients (30 eyes in each group) with a mean age of 28.63 \u00b1 6.36 years were included. The mean postoperative follow-up at the time of assessment was 9.4 \u00b1 5.3 and 8.9 \u00b1 5.28 months (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = .75) in the ICL and Eyecryl groups, respectively. The mean values of scotopic, mesopic, and photopic vault were 490.56 \u00b1 238.64, 453.56 \u00b1 224.30, and 373.96 \u00b1 200.24 \u03bcm in the ICL group and 515.46 \u00b1 174.34, 490.26 \u00b1 184.04, 450.43 \u00b1 173.92 \u03bcm in the Eyecryl group (\n                      <jats:italic toggle=\"yes\">P =<\/jats:italic>\n                      .32, .24, and .05, respectively). The DVR was 116.6 \u00b1 59.29 \u03bcm in the ICL group versus 65.03 \u00b1 31.78 \u03bcm in the Eyecryl group (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; .001).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions:<\/jats:title>\n                    <jats:p>The Eyecryl phakic IOL showed significantly fewer light-induced changes in the central vault height (DVR) compared to the ICL, which may be attributed to the difference in the material of the two phakic IOL models. This may be clinically significant in eyes with low postoperative vaults with respect to their follow-up and risk assessment of cataractogenesis in the long term.<\/jats:p>\n                    <jats:p>\n                      <jats:bold>\n                        [\n                        <jats:italic toggle=\"yes\">J Refract Surg.<\/jats:italic>\n                        2023;39(8):546\u2013554.]\n                      <\/jats:bold>\n                    <\/jats:p>\n                  <\/jats:sec>","DOI":"10.3928\/1081597x-20230626-01","type":"journal-article","created":{"date-parts":[[2023,8,14]],"date-time":"2023-08-14T08:19:37Z","timestamp":1692001177000},"page":"546-554","source":"Crossref","is-referenced-by-count":9,"title":["Comparison of Dynamic Vault Changes Following Implantation of Two Different Models of Phakic Intraocular Lenses"],"prefix":"10.3928","volume":"39","author":[{"given":"Sheetal","family":"Brar","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sanjali Tadas","family":"Wadhokar","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Supriya Samak","family":"Sriganesh","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"family":"Sriganesh","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"2308","reference":[{"key":"e_1_3_2_2_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2004.03.026"},{"key":"e_1_3_2_3_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0161-6420(02)01771-2"},{"key":"e_1_3_2_4_2","doi-asserted-by":"publisher","DOI":"10.4103\/ijo.IJO_2995_20"},{"key":"e_1_3_2_5_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(03)00239-6"},{"key":"e_1_3_2_6_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20181105-01"},{"key":"e_1_3_2_7_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(03)00065-8"},{"key":"e_1_3_2_8_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2008.03.029"},{"key":"e_1_3_2_9_2","first-page":"231","article-title":"Incidence and factors responsible for implantable collamer lens (ICL) explantation and outcomes of further management-5 year retrospective study","volume":"3","author":"Brar S","year":"2015","unstructured":"Brar S, Ganesh S, Pandey R. Incidence and factors responsible for implantable collamer lens (ICL) explantation and outcomes of further management-5 year retrospective study. EC Ophthalmol. 2015;3:231\u2013239.","journal-title":"EC Ophthalmol"},{"key":"e_1_3_2_10_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2014.08.020"},{"key":"e_1_3_2_11_2","doi-asserted-by":"publisher","DOI":"10.1167\/tvst.7.3.4"},{"key":"e_1_3_2_12_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20201013-04"},{"key":"e_1_3_2_13_2","doi-asserted-by":"publisher","DOI":"10.2147\/OPTH.S89487"},{"key":"e_1_3_2_14_2","unstructured":"Costruzione Strumenti Oftalmici. \u201cPHOENIX Software Settings.\u201d Phoenix 3.7 instructions for use. 2019. Accessed on December 12 2020. www.csoitalia.it"},{"key":"e_1_3_2_15_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2009.10.033"},{"key":"e_1_3_2_16_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1755-3768.2011.02224.x"},{"key":"e_1_3_2_17_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2003.05.013"},{"key":"e_1_3_2_18_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2011.07.001"},{"key":"e_1_3_2_19_2","doi-asserted-by":"publisher","DOI":"10.2147\/OPTH.S188785"},{"key":"e_1_3_2_20_2","doi-asserted-by":"publisher","DOI":"10.3126\/nepjoph.v7i2.14967"},{"key":"e_1_3_2_21_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2017.10.034"},{"key":"e_1_3_2_22_2","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0165469"},{"key":"e_1_3_2_23_2","doi-asserted-by":"publisher","DOI":"10.1097\/MD.0000000000003270"},{"key":"e_1_3_2_24_2","doi-asserted-by":"publisher","DOI":"10.4274\/eamr.galenos.2021.43760"},{"key":"e_1_3_2_25_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2013.12.022"},{"key":"e_1_3_2_26_2","doi-asserted-by":"publisher","DOI":"10.1097\/ICU.0b013e328333ea2f"},{"key":"e_1_3_2_27_2","unstructured":"The Engineering Toolbox. Illuminance: recommended light level. https:\/\/www.engineeringtoolbox.com\/light-level-rooms-d_708.html"},{"key":"e_1_3_2_28_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2009.12.013"}],"container-title":["Journal of Refractive Surgery"],"original-title":[],"language":"en","deposited":{"date-parts":[[2026,6,23]],"date-time":"2026-06-23T20:16:03Z","timestamp":1782245763000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.healio.com\/doi\/10.3928\/1081597X-20230626-01"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,8,1]]},"references-count":27,"journal-issue":{"issue":"8","published-print":{"date-parts":[[2023,8,1]]}},"alternative-id":["10.3928\/1081597X-20230626-01"],"URL":"https:\/\/doi.org\/10.3928\/1081597x-20230626-01","relation":{},"ISSN":["1081-597X"],"issn-type":[{"value":"1081-597X","type":"print"}],"subject":[],"published":{"date-parts":[[2023,8,1]]}}}