{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,1]],"date-time":"2026-09-01T13:25:16Z","timestamp":1788269116638,"version":"build-2803163510"},"reference-count":32,"publisher":"SLACK, Inc.","issue":"9","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Refract Surg"],"published-print":{"date-parts":[[2023,9]]},"abstract":"<jats:sec>\n            <jats:title>Purpose:<\/jats:title>\n            <jats:p>To assess the clinical and aberrometric outcomes of a new Implantable Collamer Lens (EVO Viva ICL; STAAR Surgical) to correct moderate to high myopia and presbyopia.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods:<\/jats:title>\n            <jats:p>The study included 80 eyes of 40 patients who had bilateral EVO Viva ICL implantation. Uncorrected (UDVA) and corrected (CDVA) distance visual acuities, refraction, presbyopic add power, binocular through-focus visual acuity, total ocular spherical aberration (SA), coma aberration, and root mean square of ocular higher order aberrations (RMS HOAs) (i-Trace Aberrometer; Tracey Technologies) for a 4.5-mm pupil size were evaluated.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>\n              The mean binocular postoperative UDVA and CDVA were 0.09 \u00b1 0.19 and 0.02 \u00b1 0.03 logMAR, respectively. The postoperative spherical equivalent was \u22120.61 \u00b1 0.54 diopters (D). The presbyopic add power reduced from +1.31 \u00b1 0.74 D preoperatively to +0.44 \u00b1 0.58 D after surgery (\n              <jats:italic>P<\/jats:italic>\n              &lt; .0001). The mean visual acuity was 0.1 logMAR or better (20\/25 or better) across the vergence range from +0.50 to \u22121.50 D, better than 0.2 logMAR (20\/32 or better) up to the vergence of \u22122.00 D, and remained better than 0.3 logMAR (20\/40 or better) up to the vergence of \u22122.50 D. The total ocular aberrations induced by EVO Viva ICL were \u22120.34 \u00b1 0.09 \u00b5m of SA, 0.24 \u00b1 0.18 \u00b5m of coma, and 0.26 \u00b1 0.12 \u00b5m of RMS HOAs.\n            <\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions:<\/jats:title>\n            <jats:p>The outcomes support that the new ICL might be a good alternative for myopia and presbyopia correction in patients aged between 45 and 55 years. Further studies are needed to evaluate the threshold lens misalignment from which the patient\u00b4s visual quality would be affected.<\/jats:p>\n            <jats:p>\n              <jats:bold>\n                [\n                <jats:italic>J Refract Surg<\/jats:italic>\n                . 2023;39(9):589\u2013596.]\n              <\/jats:bold>\n            <\/jats:p>\n          <\/jats:sec>","DOI":"10.3928\/1081597x-20230726-02","type":"journal-article","created":{"date-parts":[[2023,9,7]],"date-time":"2023-09-07T11:38:42Z","timestamp":1694086722000},"page":"589-596","source":"Crossref","is-referenced-by-count":18,"title":["Clinical and Aberrometric Outcomes of a New Implantable Collamer Lens for Myopia and Presbyopia Correction in Phakic Patients"],"prefix":"10.3928","volume":"39","author":[{"given":"Jos\u00e9 F.","family":"Alfonso","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Luis","family":"Fern\u00e1ndez-Vega-Cueto","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Carlos","family":"Lisa","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bel\u00e9n","family":"Alfonso-Bartolozzi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ana","family":"Palacios","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"David","family":"Madrid-Costa","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"2308","reference":[{"key":"e_1_3_2_2_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00417-012-2043-3"},{"key":"e_1_3_2_3_2","doi-asserted-by":"publisher","DOI":"10.1038\/s41433-019-0575-z"},{"key":"e_1_3_2_4_2","doi-asserted-by":"publisher","DOI":"10.1111\/aos.14599"},{"key":"e_1_3_2_5_2","doi-asserted-by":"publisher","DOI":"10.2147\/OPTH.S188785"},{"key":"e_1_3_2_6_2","doi-asserted-by":"publisher","DOI":"10.2147\/OPTH.S111620"},{"key":"e_1_3_2_7_2","doi-asserted-by":"publisher","DOI":"10.3389\/fmed.2021.799078"},{"key":"e_1_3_2_8_2","doi-asserted-by":"publisher","DOI":"10.1097\/MD.0000000000003270"},{"key":"e_1_3_2_9_2","doi-asserted-by":"publisher","DOI":"10.1186\/s40662-021-00264-0"},{"key":"e_1_3_2_10_2","doi-asserted-by":"publisher","DOI":"10.1080\/02713683.2021.2012202"},{"key":"e_1_3_2_11_2","doi-asserted-by":"publisher","DOI":"10.1186\/s40662-021-00247-1"},{"key":"e_1_3_2_12_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20190118-01"},{"key":"e_1_3_2_13_2","doi-asserted-by":"publisher","DOI":"10.1097\/j.jcrs.0000000000000425"},{"key":"e_1_3_2_14_2","doi-asserted-by":"publisher","DOI":"10.1097\/j.jcrs.0000000000000486"},{"key":"e_1_3_2_15_2","doi-asserted-by":"publisher","DOI":"10.1155\/2020\/7457902"},{"key":"e_1_3_2_16_2","doi-asserted-by":"publisher","DOI":"10.1136\/bjophthalmol-2021-319205"},{"key":"e_1_3_2_17_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00417-021-05545-x"},{"key":"e_1_3_2_18_2","first-page":"2018:6158520","article-title":"Intentional undercorrection by implantation of posterior chamber phakic intraocular lens with a central hole (Hole ICL) for early presbyopia","volume":"10","author":"Takahashi M","year":"2018","unstructured":"Takahashi M, Kamiya K, Shoji N, Kato S, Igarashi A, Shimizu K. Intentional undercorrection by implantation of posterior chamber phakic intraocular lens with a central hole (Hole ICL) for early presbyopia. Biomed Res Int. 2018; 10: 2018:6158520.","journal-title":"Biomed Res Int"},{"key":"e_1_3_2_19_2","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-017-11539-9"},{"key":"e_1_3_2_20_2","doi-asserted-by":"publisher","DOI":"10.2147\/OPTH.S271858"},{"key":"e_1_3_2_21_2","unstructured":"Ossipov AV and Holliday K inventor; STAAR Surgical Company assignee. Polymeric composition exhibiting nanogradient of refractive index. Patent No US 10 774 164. September 15 2020."},{"key":"e_1_3_2_22_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2013.01.030"},{"key":"e_1_3_2_23_2","doi-asserted-by":"publisher","DOI":"10.1136\/bjophthalmol-2013-303787"},{"key":"e_1_3_2_24_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2012.01.029"},{"key":"e_1_3_2_25_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2004.09.024"},{"key":"e_1_3_2_26_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081-597X-20021101-04"},{"key":"e_1_3_2_27_2","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.08-2187"},{"key":"e_1_3_2_28_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2009.01.034"},{"key":"e_1_3_2_29_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2011.02.025"},{"key":"e_1_3_2_30_2","doi-asserted-by":"publisher","DOI":"10.1038\/s41433-018-0068-5"},{"key":"e_1_3_2_31_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2018.10.045"},{"key":"e_1_3_2_32_2","doi-asserted-by":"publisher","DOI":"10.1186\/s12886-022-02499-4"},{"key":"e_1_3_2_33_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00417-022-05929-7"}],"container-title":["Journal of Refractive Surgery"],"original-title":[],"language":"en","deposited":{"date-parts":[[2023,9,7]],"date-time":"2023-09-07T11:38:47Z","timestamp":1694086727000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.healio.com\/doi\/10.3928\/1081597X-20230726-02"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,9]]},"references-count":32,"journal-issue":{"issue":"9","published-print":{"date-parts":[[2023,9]]}},"alternative-id":["10.3928\/1081597X-20230726-02"],"URL":"https:\/\/doi.org\/10.3928\/1081597x-20230726-02","relation":{},"ISSN":["1081-597X"],"issn-type":[{"value":"1081-597X","type":"print"}],"subject":[],"published":{"date-parts":[[2023,9]]}}}