{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,21]],"date-time":"2026-08-21T12:46:44Z","timestamp":1787316404410,"version":"build-2736575974"},"reference-count":39,"publisher":"SLACK, Inc.","issue":"11","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Refract Surg"],"published-print":{"date-parts":[[2023,11]]},"abstract":"<jats:sec>\n                    <jats:title>Purpose:<\/jats:title>\n                    <jats:p>To assess the predictability between the SCHWIND ATOS femtosecond laser (SCHWIND eye-tech-solutions) read-out and achieved lenticule thickness measured using MS-39 anterior segment optical coherence tomography (ASOCT; CSO) at the corneal vertex at postoperative 1 day and 1 and 3 months of follow-up.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>This retrospective case series included 130 eyes of 65 consecutive patients who were treated with SmartSight (SCHWIND eye-tech-solutions) lenticule extraction. Sixty-four percent of patients were women with a mean spherical refraction of \u22124.98 \u00b1 1.19 diopters (D) and mean astigmatism of 0.53 \u00b1 0.64 D. The measurements were performed using AS-OCT with the Phoenix Software v 4.1.1.5. Lenticule thickness was obtained by the subtraction method between preoperative and postoperative total corneal thickness.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>A lower reduction in central corneal thickness (CCT) compared to the laser read-out for all three follow-up visits can be observed. Essentially, the reduction in CCT was identical at 3 months versus 1 month. The reduction in CCT was lowest at postoperative 1 day. Examining the 1- and 3-month data (essentially equivalent), one can see a best fit of y = 0.94 x \u22127 \u00b5m.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions:<\/jats:title>\n                    <jats:p>The reduction in CCT was stable from 1 month of follow-up. The stable reduction in CCT was \u22126% (\u22121.5% after accounting for design decisions) and \u22127 \u00b5m lower than the respective laser read-out. The findings are predictable, showing a certain level of the lenticules becoming slightly thinner than their respective laser read-outs.<\/jats:p>\n                    <jats:p>\n                      <jats:bold>\n                        [\n                        <jats:italic>J Refract Surg<\/jats:italic>\n                        . 2023;39(11):728\u2013735.]\n                      <\/jats:bold>\n                    <\/jats:p>\n                  <\/jats:sec>","DOI":"10.3928\/1081597x-20230925-02","type":"journal-article","created":{"date-parts":[[2023,11,8]],"date-time":"2023-11-08T07:22:41Z","timestamp":1699428161000},"page":"728-735","source":"Crossref","is-referenced-by-count":10,"title":["Predictability of the Achieved Lenticule Thickness in Keratorefractive Lenticule Extraction for Myopia Correction"],"prefix":"10.3928","volume":"39","author":[{"given":"Maja","family":"Boha\u010d","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ivan","family":"Gabri\u0107","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kre\u0161imir","family":"Gabri\u0107","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mateja","family":"Jagi\u0107","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Samuel","family":"Arba Mosquera","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"2308","reference":[{"key":"e_1_3_2_2_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(88)80063-4"},{"key":"e_1_3_2_3_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20210427-03"},{"key":"e_1_3_2_4_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0002-9394(14)72896-X"},{"key":"e_1_3_2_5_2","doi-asserted-by":"publisher","DOI":"10.1097\/ICO.0000000000001821"},{"issue":"4","key":"e_1_3_2_6_2","first-page":"1","article-title":"Initial experience with the SCHWIND ATOS and SmartSight lenticule extraction","volume":"3","author":"Pradhan KR","year":"2020","unstructured":"Pradhan KR, Arba Mosquera S. Initial experience with the SCHWIND ATOS and SmartSight lenticule extraction. J Clin Res Med. 2020;3(4):1\u20135.","journal-title":"J Clin Res Med"},{"key":"e_1_3_2_7_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20210210-02"},{"key":"e_1_3_2_8_2","doi-asserted-by":"publisher","DOI":"10.1097\/ICU.0000000000000383"},{"key":"e_1_3_2_9_2","doi-asserted-by":"publisher","DOI":"10.1063\/1.4892665"},{"key":"e_1_3_2_10_2","doi-asserted-by":"publisher","DOI":"10.1117\/1.JBO.20.12.125004"},{"issue":"7","key":"e_1_3_2_11_2","first-page":"3032","article-title":"Intraocular photodisruption with picosecond and nanosecond laser pulses: tissue effects in cornea, lens, and retina","volume":"35","author":"Vogel A","year":"1994","unstructured":"Vogel A, Capon MR, Asiyo-Vogel MN, Birngruber R. Intraocular photodisruption with picosecond and nanosecond laser pulses: tissue effects in cornea, lens, and retina. Invest Ophthalmol Vis Sci. 1994;35(7):3032\u20133044. PMID:8206720","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"e_1_3_2_12_2","doi-asserted-by":"publisher","DOI":"10.1364\/BOE.425895"},{"key":"e_1_3_2_13_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081-597X-20070201-13"},{"key":"e_1_3_2_14_2","doi-asserted-by":"publisher","DOI":"10.1515\/aot-2021-0039"},{"key":"e_1_3_2_15_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20200210-01"},{"key":"e_1_3_2_16_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20140218-02"},{"key":"e_1_3_2_17_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20200827-01"},{"key":"e_1_3_2_18_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2018.12.001"},{"key":"e_1_3_2_19_2","unstructured":"MS-39-CSO Italia [Internet]. Accessed February 11 2023. www.csoitalia.it\/en\/prodotto\/info\/63-ms-39-as-oct"},{"key":"e_1_3_2_20_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20140416-01"},{"key":"e_1_3_2_21_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.optom.2021.11.001"},{"key":"e_1_3_2_22_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20120127-02"},{"key":"e_1_3_2_23_2","doi-asserted-by":"publisher","DOI":"10.1364\/BOE.5.001089"},{"key":"e_1_3_2_24_2","doi-asserted-by":"publisher","DOI":"10.2174\/1874364101105010051"},{"key":"e_1_3_2_25_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1600-0420.2006.00852.x"},{"key":"e_1_3_2_26_2","doi-asserted-by":"publisher","DOI":"10.1034\/j.1600-0420.2001.079004381.x"},{"key":"e_1_3_2_27_2","doi-asserted-by":"publisher","DOI":"10.1076\/ceyr.16.7.640.5058"},{"issue":"3","key":"e_1_3_2_28_2","first-page":"487","article-title":"Confocal microscopic characterization of wound repair after photorefractive keratectomy","volume":"39","author":"M\u00f8ller-Pedersen T","year":"1998","unstructured":"M\u00f8ller-Pedersen T, Li HF, Petroll WM, Cavanagh HD, Jester JV. Confocal microscopic characterization of wound repair after photorefractive keratectomy. Invest Ophthalmol Vis Sci. 1998;39(3):487\u2013501. PMID:9501858","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"e_1_3_2_29_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20100114-02"},{"key":"e_1_3_2_30_2","doi-asserted-by":"publisher","DOI":"10.1167\/tvst.11.6.20"},{"key":"e_1_3_2_31_2","doi-asserted-by":"publisher","DOI":"10.3390\/jpm13020256"},{"key":"e_1_3_2_32_2","doi-asserted-by":"publisher","DOI":"10.1186\/s12886-020-01374-4"},{"key":"e_1_3_2_33_2","doi-asserted-by":"publisher","DOI":"10.1097\/ICL.0000000000000504"},{"key":"e_1_3_2_34_2","doi-asserted-by":"publisher","DOI":"10.1080\/02713683.2021.1877310"},{"key":"e_1_3_2_35_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00417-019-04529-2"},{"key":"e_1_3_2_36_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20180516-01"},{"key":"e_1_3_2_37_2","doi-asserted-by":"publisher","DOI":"10.1007\/s40123-022-00629-1"},{"key":"e_1_3_2_38_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20211112-01"},{"key":"e_1_3_2_39_2","doi-asserted-by":"publisher","DOI":"10.1097\/j.jcrs.0000000000000765"},{"key":"e_1_3_2_40_2","doi-asserted-by":"publisher","DOI":"10.1038\/s41433-023-02601-0"}],"container-title":["Journal of Refractive Surgery"],"original-title":[],"language":"en","deposited":{"date-parts":[[2023,11,8]],"date-time":"2023-11-08T07:23:02Z","timestamp":1699428182000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.healio.com\/doi\/10.3928\/1081597X-20230925-02"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,11]]},"references-count":39,"journal-issue":{"issue":"11","published-print":{"date-parts":[[2023,11]]}},"alternative-id":["10.3928\/1081597X-20230925-02"],"URL":"https:\/\/doi.org\/10.3928\/1081597x-20230925-02","relation":{},"ISSN":["1081-597X"],"issn-type":[{"value":"1081-597X","type":"print"}],"subject":[],"published":{"date-parts":[[2023,11]]}}}