{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,17]],"date-time":"2026-11-17T11:43:13Z","timestamp":1794915793722,"version":"4.9.1"},"reference-count":33,"publisher":"SLACK, Inc.","issue":"2","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Refract Surg"],"published-print":{"date-parts":[[2024,2]]},"abstract":"<jats:sec>\n                    <jats:title>Purpose:<\/jats:title>\n                    <jats:p>To explore a potential functional classification of intraocular lenses (IOLs) based on monocular visual acuity defocus curves (VADCs) as a primary end-point.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>A systematic literature search was conducted using PubMed. Two independent reviewers screened the literature for inclusion and data extraction. Inclusion criteria were full-text primary clinical studies of IOLs, published in English from 2010 onward, involving patients undergoing cataract or refractive lens exchange. A cluster analysis was conducted to explore similarities in the range of field (RoF) and increase of visual acuity from intermediate to near (\u0394VA).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>A total of 107 studies were ultimately included from the 436 identified in the systematic search, with an additional 5 studies added through the snowballing technique search. The cluster analysis was conducted using 69 reports that included monocular VADCs. Two main categories were identified based on the achieved RoF for 0.2 and 0.3 logMAR: full (FRoF) and partial (PRoF) RoF IOLs. Three subcategories were identified for FRoF depending on \u0394VA: continuous (FRoF-C), smooth (FRoF-Sm), and steep (FRoF-St). On the other hand, PRoF IOLs shared the characteristic of monotonous decrease in visual acuity and were subclassified into two subcategories depending on the achieved RoF: narrowed (PRoF-N) and extended (PRoF-Ex). An additional subcategory was added to PRoF, enhanced (PRoF-En), for 7 reports alternating between PRoF-N and PRoF-Ex depending on the use of 0.2 or 0.3 logMAR as a cut-off for calculating the RoF.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions:<\/jats:title>\n                    <jats:p>IOLs can be functionally classified into six types depending on the RoF and shape of the monocular VADC.<\/jats:p>\n                    <jats:p>\n                      [\n                      <jats:bold>\n                        <jats:italic>J Refract Surg<\/jats:italic>\n                        . 2024;40(2):e108\u2013e116.]\n                      <\/jats:bold>\n                    <\/jats:p>\n                  <\/jats:sec>","DOI":"10.3928\/1081597x-20231212-01","type":"journal-article","created":{"date-parts":[[2024,2,12]],"date-time":"2024-02-12T14:03:03Z","timestamp":1707746583000},"source":"Crossref","is-referenced-by-count":54,"title":["Functional Classification of Intraocular Lenses Based on Defocus Curves: A Scoping Review and Cluster Analysis"],"prefix":"10.3928","volume":"40","author":[{"given":"Joaqu\u00edn","family":"Fern\u00e1ndez","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Filomena","family":"Ribeiro","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Carlos","family":"Rocha-de-Lossada","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Manuel","family":"Rodr\u00edguez-Vallejo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"2308","reference":[{"key":"e_1_3_2_2_2","unstructured":"Eyewire. New Technology Greater Patient Awareness Will Help Drive Gains in Premium Cataract Surgery. Source: Market Scope's \u201c2021 Premium Cataract Surgery Market Report.\u201d Published 2021. Accessed December 14 2023. https:\/\/eyewire.news\/news\/new-technology-greater-patient-awareness-will-help-drive-gains-in-premium-cataract-surgery"},{"key":"e_1_3_2_3_2","doi-asserted-by":"publisher","DOI":"10.1097\/APO.0000000000000253"},{"key":"e_1_3_2_4_2","doi-asserted-by":"publisher","DOI":"10.1097\/APO.0000000000000296"},{"key":"e_1_3_2_5_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2020.09.026"},{"key":"e_1_3_2_6_2","doi-asserted-by":"publisher","DOI":"10.1186\/s12886-023-02844-1"},{"key":"e_1_3_2_7_2","doi-asserted-by":"publisher","DOI":"10.1097\/j.jcrs.0000000000000061"},{"key":"e_1_3_2_8_2","unstructured":"Daya SM. A discussion on modern IOL terminology. Published 2021. Accessed February 23 2023. https:\/\/crstodayeurope.com\/articles\/feb-2021\/lets-speak-lenspeak\/"},{"key":"e_1_3_2_9_2","doi-asserted-by":"publisher","DOI":"10.2147\/OPTH.S318065"},{"key":"e_1_3_2_10_2","doi-asserted-by":"publisher","DOI":"10.1097\/j.jcrs.0000000000000826"},{"key":"e_1_3_2_11_2","unstructured":"Vision J&JS. Johnson & Johnson Vision Introduces All Purpose EDOF TECNIS Symfony OptiBlue IOL the Latest PC-IOL Powered by InteliLight Technology. Accessed April 5 2023. https:\/\/www.jnj.com\/johnson-johnson-vision-introduces-all-purpose-edof-tecnis-symfony-optiblue-iol-the-latest-pc-iol-powered-by-intelilight-technology#_ftnref11"},{"key":"e_1_3_2_12_2","doi-asserted-by":"publisher","DOI":"10.1097\/APO.0000000000000590"},{"key":"e_1_3_2_13_2","unstructured":"Z80. 35-2018 A. Extended depth of focus intraocular lenses for presbyopia. Accessed December 14 2023. https:\/\/webstore.ansi.org\/standards\/vc%20(asc%20z80)\/ansiz80352018"},{"key":"e_1_3_2_14_2","unstructured":"International Organization for Standardization. ISO-11979-7:2018. Ophthalmic implants\u2014Intraocular lenses\u2014Part 7: Clinical investigations. Published 2018. Accessed December 14 2023. https:\/\/www.iso.org\/standard\/69038.html"},{"key":"e_1_3_2_15_2","doi-asserted-by":"publisher","DOI":"10.1097\/j.jcrs.0000000000001013"},{"key":"e_1_3_2_16_2","doi-asserted-by":"publisher","DOI":"10.1155\/2021\/1115076"},{"key":"e_1_3_2_17_2","doi-asserted-by":"publisher","DOI":"10.1186\/s12886-019-1078-1"},{"key":"e_1_3_2_18_2","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-021-86222-1"},{"key":"e_1_3_2_19_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00417-018-04218-6"},{"key":"e_1_3_2_20_2","doi-asserted-by":"publisher","DOI":"10.1186\/s12886-019-1204-0"},{"key":"e_1_3_2_21_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2023.01.024"},{"key":"e_1_3_2_22_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.survophthal.2019.02.012"},{"key":"e_1_3_2_23_2","doi-asserted-by":"publisher","DOI":"10.1001\/jamaophthalmol.2022.3667"},{"key":"e_1_3_2_24_2","doi-asserted-by":"publisher","DOI":"10.1002\/14651858.CD012648.pub3"},{"key":"e_1_3_2_25_2","doi-asserted-by":"publisher","DOI":"10.2147\/OPTH.S326139"},{"key":"e_1_3_2_26_2","doi-asserted-by":"publisher","DOI":"10.1136\/bjophthalmol-2019-315410"},{"key":"e_1_3_2_27_2","doi-asserted-by":"publisher","DOI":"10.46658\/JBIMES-20-12"},{"key":"e_1_3_2_28_2","doi-asserted-by":"publisher","DOI":"10.7326\/M18-0850"},{"key":"e_1_3_2_29_2","doi-asserted-by":"crossref","first-page":"452","DOI":"10.1007\/978-3-658-32589-3","volume-title":"Multivariate Analysis: An Application-Oriented Introduction","author":"Backhaus K","year":"2021","unstructured":"Backhaus K, Erichson B, Gensler S, Weiber R, Weiber T. Cluster analysis. In: Backhaus K, Erichson B, Gensler S, Weiber R, Weiber T. Multivariate Analysis: An Application-Oriented Introduction. Springer; 2021:452\u2013496."},{"key":"e_1_3_2_30_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20190618-01"},{"key":"e_1_3_2_31_2","doi-asserted-by":"publisher","DOI":"10.1364\/AO.51.008594"},{"key":"e_1_3_2_32_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20190306-01"},{"key":"e_1_3_2_33_2","unstructured":"International Organization for Standardization. ISO-11979-7:2023(E). Ophthalmic implants\u2014Intraocular lenses\u2014Part 7: Clinical investigations. Accessed December 14 2023. https:\/\/standards.iteh.ai\/catalog\/standards\/sist\/fe10ebd0-75a2-4940-803a-e38b457b1d5d\/osist-pren-iso-11979-7-2023"},{"key":"e_1_3_2_34_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20220707-01"}],"container-title":["Journal of Refractive Surgery"],"original-title":[],"language":"en","deposited":{"date-parts":[[2024,2,12]],"date-time":"2024-02-12T14:03:06Z","timestamp":1707746586000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.healio.com\/doi\/10.3928\/1081597X-20231212-01"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,2]]},"references-count":33,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2024,2]]}},"alternative-id":["10.3928\/1081597X-20231212-01"],"URL":"https:\/\/doi.org\/10.3928\/1081597x-20231212-01","relation":{},"ISSN":["1081-597X"],"issn-type":[{"value":"1081-597X","type":"print"}],"subject":[],"published":{"date-parts":[[2024,2]]}}}