{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,10]],"date-time":"2026-09-10T04:23:09Z","timestamp":1789014189100,"version":"build-2803163510"},"reference-count":21,"publisher":"SLACK, Inc.","issue":"2","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Refract Surg"],"published-print":{"date-parts":[[2024,2]]},"abstract":"<jats:sec>\n            <jats:title>Purpose:<\/jats:title>\n            <jats:p>To identify risk factors that increase the likelihood of re-treatment following refractive surgery in patients with mixed astigmatism.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods:<\/jats:title>\n            <jats:p>This was a retrospective study including patients who underwent either laser in situ keratomileusis (LASIK) or photorefractive keratectomy (PRK) between 2000 and 2019 and had mixed astigmatism (spherical error of +0.50 D or greater and spherical equivalent of less than 0.00 diopters [D]). Patients were divided into two groups according to whether they underwent re-treatments during the study period.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>\n              Overall, 785 eyes (785 patients) were included. In total, 5.2% of the eyes (n = 41) underwent re-treatment. The re-treatment group was more likely to have preoperative high astigmatism (80.5% vs 48.3%,\n              <jats:italic>P<\/jats:italic>\n              &lt; .001), moderate to high hyperopia (36.6% vs 22.3%,\n              <jats:italic>P<\/jats:italic>\n              = .035), and to have undergone surgery earlier during the study period (\n              <jats:italic>P<\/jats:italic>\n              &lt; .001). They were also more likely to have undergone surgery using the Wave-Light EX200 rather than the EX500 laser platform (Alcon Laboratories, Inc) (\n              <jats:italic>P<\/jats:italic>\n              &lt; .001), have a treated optical zone of 6 mm rather than 6.5 mm (\n              <jats:italic>P<\/jats:italic>\n              &lt; .001 for both), and their maximum ablation depth was greater (\n              <jats:italic>P<\/jats:italic>\n              &lt; .001). There was no difference between the re-treatment and control groups regarding procedure type (PRK vs LASIK). Binary logistic regression found preoperative high astigmatism (odds ratio = 3.97,\n              <jats:italic>P<\/jats:italic>\n              &lt; .001) and the type of laser platform used (EX200, odds ratio = 7.78,\n              <jats:italic>P<\/jats:italic>\n              &lt; .001) as the only independent factors associated with re-treatment.\n            <\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions:<\/jats:title>\n            <jats:p>Re-treatment rates following correction of mixed astigmatism were 5.2% over 20 years. Use of a sixth-generation laser platform significantly reduced the risk of re-treatment. Presence of high astigmatism is a significant risk factor for re-treatment. There was no difference in retreatment risk between PRK and LASIK.<\/jats:p>\n            <jats:p>\n              <jats:bold>\n                [\n                <jats:italic>J Refract Surg<\/jats:italic>\n                . 2024;40(2):e73\u2013e78.]\n              <\/jats:bold>\n            <\/jats:p>\n          <\/jats:sec>","DOI":"10.3928\/1081597x-20231212-06","type":"journal-article","created":{"date-parts":[[2024,2,12]],"date-time":"2024-02-12T19:03:03Z","timestamp":1707764583000},"source":"Crossref","is-referenced-by-count":5,"title":["Factors Predicting the Need for Re-treatment After Laser Refractive Surgery in Patients With Mixed Astigmatism"],"prefix":"10.3928","volume":"40","author":[{"given":"Nir","family":"Sorkin","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Igor","family":"Kaiserman","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mohamad","family":"Kayal","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Eliya","family":"Levinger","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Raneen Shehadeh","family":"Mashour","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tzahi","family":"Sela","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gur","family":"Munzer","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michael","family":"Mimouni","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"2308","reference":[{"key":"e_1_3_2_2_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20170616-01"},{"key":"e_1_3_2_3_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20210226-01"},{"key":"e_1_3_2_4_2","doi-asserted-by":"publisher","DOI":"10.1111\/opo.12009"},{"key":"e_1_3_2_5_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2016.07.032"},{"key":"e_1_3_2_6_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2017.06.001"},{"key":"e_1_3_2_7_2","doi-asserted-by":"publisher","DOI":"10.1097\/ICO.0000000000000795"},{"key":"e_1_3_2_8_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20151021-05"},{"key":"e_1_3_2_9_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081-597X-20061001-09"},{"key":"e_1_3_2_10_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(03)00071-3"},{"key":"e_1_3_2_11_2","doi-asserted-by":"publisher","unstructured":"Ortueta D de Mosquera SA Haecker C Ortueta D de Mosquera SA Haecker C. Treating mixed astigmatism: a theoretical comparison and guideline for combined ablation strategies and wavefront ablation. In Goggin M. Astigmatism: Optics Physiology and Management. Published online February 29 2012. 10.5772\/19623","DOI":"10.5772\/19623"},{"key":"e_1_3_2_12_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081-597X-19980401-05"},{"key":"e_1_3_2_13_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081-597X-19990302-04"},{"key":"e_1_3_2_14_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081-597X-20010302-20"},{"key":"e_1_3_2_15_2","doi-asserted-by":"publisher","DOI":"10.1177\/112067210801800603"},{"key":"e_1_3_2_16_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0161-6420(00)00498-X"},{"key":"e_1_3_2_17_2","doi-asserted-by":"publisher","DOI":"10.3906\/sag-1504-35"},{"issue":"1","key":"e_1_3_2_18_2","first-page":"277","article-title":"Femtosecond-LASIK outcomes using the VisuMax\u00ae-MEL\u00ae 80 platform for mixed astigmatism refractive surgery","volume":"59","author":"Stanca HT","year":"2018","unstructured":"Stanca HT, Munteanu M, Jianu DC, . Femtosecond-LASIK outcomes using the VisuMax\u00ae-MEL\u00ae 80 platform for mixed astigmatism refractive surgery. Rom J Morphol Embryol. 2018;59(1):277\u2013283. PMID:29940638","journal-title":"Rom J Morphol Embryol"},{"key":"e_1_3_2_19_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2012.11.027"},{"key":"e_1_3_2_20_2","doi-asserted-by":"publisher","DOI":"10.1097\/j.jcrs.0000000000000476"},{"key":"e_1_3_2_21_2","doi-asserted-by":"publisher","DOI":"10.1007\/s40123-022-00472-4"},{"key":"e_1_3_2_22_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081-597X-20041101-12"}],"container-title":["Journal of Refractive Surgery"],"original-title":[],"language":"en","deposited":{"date-parts":[[2024,2,12]],"date-time":"2024-02-12T19:03:37Z","timestamp":1707764617000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.healio.com\/doi\/10.3928\/1081597X-20231212-06"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,2]]},"references-count":21,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2024,2]]}},"alternative-id":["10.3928\/1081597X-20231212-06"],"URL":"https:\/\/doi.org\/10.3928\/1081597x-20231212-06","relation":{},"ISSN":["1081-597X"],"issn-type":[{"value":"1081-597X","type":"print"}],"subject":[],"published":{"date-parts":[[2024,2]]}}}