{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,11]],"date-time":"2026-09-11T15:39:50Z","timestamp":1789141190519,"version":"build-2803163510"},"reference-count":70,"publisher":"SLACK, Inc.","issue":"3","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Refract Surg"],"published-print":{"date-parts":[[2024,3]]},"abstract":"<jats:sec>\n            <jats:title>Purpose:<\/jats:title>\n            <jats:p>To provide an up-to-date review of the agreement in automated white-to-white (WTW) measurement between the latest topographic and biometric devices.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods:<\/jats:title>\n            <jats:p>In this systematic review, PubMed, Web of Science, and Scopus databases were searched for articles published between 2017 and 2023, focusing on WTW agreement studies on adult, virgin eyes, with or without cataract and no other ocular comorbidities. Studies evaluating WTW measurements performed with autokeratometers, manual calipers, or manual image analysis were excluded. When available, the following metrics for the agreement of WTW measurements between pairs of devices were included: mean difference \u00b1 standard deviation, 95% limits of agreement (LoA), LoA width, 95% confidence interval (95 CI%), and intraclass correlation coefficient (ICC).<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>Forty-one studies, covering comparisons for 19 devices, were included. Altogether, 81 paired comparisons were performed for 4,595 eyes of 4,002 individuals. The mean difference in WTW measurements between devices ranged from 0.01 mm up to 0.96 mm, with varying CI. The 95% LoA width ranged from 0.31 to 2.45 mm (median: 0.65 mm). The majority of pairwise comparisons reported LoA wider than 0.5 mm, a clinically significant value for phakic intraocular lens sizing.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions:<\/jats:title>\n            <jats:p>Nearly all analyzed studies demonstrated the lack of interchangeability of the WTW parameter. The corneal diameter, assessed by means of grayscale en-face image analysis, tended to demonstrate the lowest agreement among devices compared to other measured biometric parameters.<\/jats:p>\n            <jats:p>\n              <jats:bold>\n                [\n                <jats:italic>J Refract Surg<\/jats:italic>\n                . 2024;40(3):e182\u2013e194.]\n              <\/jats:bold>\n            <\/jats:p>\n          <\/jats:sec>","DOI":"10.3928\/1081597x-20240212-02","type":"journal-article","created":{"date-parts":[[2024,3,11]],"date-time":"2024-03-11T17:49:59Z","timestamp":1710179399000},"source":"Crossref","is-referenced-by-count":7,"title":["Interchangeability in Automated Corneal Diameter Measurements Across Different Biometric Devices: A Systematic Review of Agreement Studies"],"prefix":"10.3928","volume":"40","author":[{"given":"Maria","family":"Muzyka-Wo\u017aniak","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Slawomir","family":"Wo\u017aniak","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Grzegorz","family":"\u0141abuz","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"2308","reference":[{"key":"e_1_3_2_2_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2003.06.004"},{"key":"e_1_3_2_3_2","doi-asserted-by":"publisher","DOI":"10.18240\/ijo.2016.07.20"},{"key":"e_1_3_2_4_2","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0278884"},{"key":"e_1_3_2_5_2","doi-asserted-by":"publisher","DOI":"10.1097\/j.jcrs.0000000000000551"},{"key":"e_1_3_2_6_2","doi-asserted-by":"publisher","DOI":"10.1186\/s40662-023-00330-9"},{"key":"e_1_3_2_7_2","doi-asserted-by":"publisher","DOI":"10.1007\/978-1-4471-6784-6"},{"key":"e_1_3_2_8_2","doi-asserted-by":"publisher","DOI":"10.1111\/cxo.12583"},{"key":"e_1_3_2_9_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2017.02.027"},{"key":"e_1_3_2_10_2","unstructured":"Heidelberg Engineering GmbH. ANTERION\u00ae Hardware Manual Article No. 230031-009 INT.AE22. January 2022. Downloaded from www.Manualslib.com manuals search engine"},{"key":"e_1_3_2_11_2","doi-asserted-by":"publisher","DOI":"10.1097\/j.jcrs.0000000000000690"},{"key":"e_1_3_2_12_2","unstructured":"Topcon. ALADDIN\u2013User manual Rev. 23. Downloaded 08\/07\/2016 from www.Manualslib.com manuals search engine"},{"key":"e_1_3_2_13_2","unstructured":"ATLAS User Manual 2660021143529 Rev. C 2015-10"},{"key":"e_1_3_2_14_2","doi-asserted-by":"publisher","DOI":"10.1007\/s10792-020-01552-9"},{"key":"e_1_3_2_15_2","unstructured":"Haag Streit AG. Instructions For Use Biometer EYESTAR 900\u00a8 3. Edition\/2023\u201301. HS-Doc. no. 1500.7220686-04030\u20132023\u201301."},{"key":"e_1_3_2_16_2","unstructured":"Ziemer Ophthalmic Systems AG. GALILEI G4 Operator Manual. Doc. No. CM3941-0081-03. 2016."},{"key":"e_1_3_2_17_2","unstructured":"Carl Zeiss Meditec AG. User manual IOLMaster 700; Software version 1.90 Documentation set. 000000-1932-169-GA-en-GB-280122. 2022."},{"key":"e_1_3_2_18_2","unstructured":"Instructions For Use Biometer Lenstar LS 900\u00ae 10. Edition\/2015\u201306. 01-IFU_LS900-7220055-04100_eng.indd 1. Downloaded from www.Manualslib.com manuals search engine"},{"key":"e_1_3_2_19_2","doi-asserted-by":"publisher","DOI":"10.1097\/OPX.0000000000000799"},{"key":"e_1_3_2_20_2","unstructured":"INSTRUCTION MANUAL Multifunction Unit MR-600028AA9090-10"},{"key":"e_1_3_2_21_2","unstructured":"Costruzione Strumenti Oftalmici. MS-39 AS-OCT. Instructions for Use. IFU302EN00\u201303\/2019. www.csoitalia.it"},{"key":"e_1_3_2_22_2","unstructured":"Instruction Manual Pentacam\u00ae AXL (G\/70100\/EN 1121 Rev04)"},{"key":"e_1_3_2_23_2","unstructured":"Costruzione Strumenti Oftalmici. Corneal Topograph\/Tomograph Sirius+ Instructions For Use. IFU327EN00\u201301\/2021. www.csoitalia.it"},{"key":"e_1_3_2_24_2","doi-asserted-by":"publisher","DOI":"10.1136\/bjo-2023-323268"},{"key":"e_1_3_2_25_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.pdpdt.2022.103207"},{"key":"e_1_3_2_26_2","doi-asserted-by":"publisher","DOI":"10.3341\/kjo.2017.0091"},{"key":"e_1_3_2_27_2","doi-asserted-by":"publisher","DOI":"10.3341\/kjo.2022.0025"},{"key":"e_1_3_2_28_2","doi-asserted-by":"publisher","DOI":"10.1136\/bmjophth-2021-000941"},{"key":"e_1_3_2_29_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2019.03.020"},{"key":"e_1_3_2_30_2","doi-asserted-by":"publisher","DOI":"10.1097\/j.jcrs.0000000000000976"},{"key":"e_1_3_2_31_2","doi-asserted-by":"publisher","DOI":"10.1097\/j.jcrs.0000000000000974"},{"key":"e_1_3_2_32_2","doi-asserted-by":"publisher","DOI":"10.1097\/j.jcrs.0000000000001146"},{"key":"e_1_3_2_33_2","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0268856"},{"key":"e_1_3_2_34_2","doi-asserted-by":"publisher","DOI":"10.1097\/ICL.0000000000000786"},{"key":"e_1_3_2_35_2","doi-asserted-by":"publisher","DOI":"10.1111\/cxo.13101"},{"key":"e_1_3_2_36_2","doi-asserted-by":"publisher","DOI":"10.1097\/j.jcrs.0000000000000483"},{"key":"e_1_3_2_37_2","doi-asserted-by":"publisher","DOI":"10.1080\/17434440.2021.1905518"},{"key":"e_1_3_2_38_2","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0254832"},{"key":"e_1_3_2_39_2","doi-asserted-by":"publisher","DOI":"10.1080\/17434440.2018.1481745"},{"key":"e_1_3_2_40_2","doi-asserted-by":"publisher","DOI":"10.1097\/ICO.0000000000002964"},{"key":"e_1_3_2_41_2","doi-asserted-by":"publisher","DOI":"10.1097\/ICO.0000000000001300"},{"key":"e_1_3_2_42_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.pdpdt.2023.103646"},{"key":"e_1_3_2_43_2","doi-asserted-by":"publisher","DOI":"10.4103\/ijo.IJO_2217_21"},{"key":"e_1_3_2_44_2","doi-asserted-by":"publisher","DOI":"10.3389\/fmed.2021.814519"},{"key":"e_1_3_2_45_2","doi-asserted-by":"publisher","DOI":"10.1097\/j.jcrs.0000000000001023"},{"key":"e_1_3_2_46_2","doi-asserted-by":"publisher","DOI":"10.1136\/bjophthalmol-2016-309365"},{"key":"e_1_3_2_47_2","doi-asserted-by":"publisher","DOI":"10.4103\/ijo.IJO_2433_21"},{"key":"e_1_3_2_48_2","doi-asserted-by":"publisher","DOI":"10.1097\/j.jcrs.0000000000000704"},{"key":"e_1_3_2_49_2","doi-asserted-by":"publisher","DOI":"10.1097\/j.jcrs.0000000000000788"},{"key":"e_1_3_2_50_2","doi-asserted-by":"publisher","DOI":"10.2147\/OPTH.S278701"},{"key":"e_1_3_2_51_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20200420-02"},{"key":"e_1_3_2_52_2","doi-asserted-by":"publisher","DOI":"10.1177\/1120672118802918"},{"key":"e_1_3_2_53_2","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-020-59919-y"},{"key":"e_1_3_2_54_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2018.10.033"},{"key":"e_1_3_2_55_2","doi-asserted-by":"publisher","DOI":"10.4103\/ijo.IJO_249_22"},{"key":"e_1_3_2_56_2","doi-asserted-by":"publisher","DOI":"10.1097\/ICL.0000000000000603"},{"key":"e_1_3_2_57_2","doi-asserted-by":"publisher","DOI":"10.1177\/11206721221143160"},{"key":"e_1_3_2_58_2","doi-asserted-by":"publisher","DOI":"10.1097\/j.jcrs.0000000000000942"},{"key":"e_1_3_2_59_2","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-017-02463-z"},{"key":"e_1_3_2_60_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2019.03.016"},{"key":"e_1_3_2_61_2","doi-asserted-by":"publisher","DOI":"10.2147\/OPTH.S274303"},{"key":"e_1_3_2_62_2","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0277703"},{"key":"e_1_3_2_63_2","doi-asserted-by":"publisher","DOI":"10.3390\/medicina59050899"},{"key":"e_1_3_2_64_2","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0251990"},{"key":"e_1_3_2_65_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.preteyeres.2015.07.001"},{"key":"e_1_3_2_66_2","doi-asserted-by":"publisher","DOI":"10.1111\/opo.13020"},{"key":"e_1_3_2_67_2","doi-asserted-by":"publisher","DOI":"10.1097\/j.jcrs.0000000000001207"},{"key":"e_1_3_2_68_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20200630-01"},{"key":"e_1_3_2_69_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2010.07.014"},{"key":"e_1_3_2_70_2","doi-asserted-by":"publisher","DOI":"10.1080\/17434440.2020.1816463"},{"key":"e_1_3_2_71_2","doi-asserted-by":"publisher","DOI":"10.1186\/s40662-020-00208-0"}],"container-title":["Journal of Refractive Surgery"],"original-title":[],"language":"en","deposited":{"date-parts":[[2024,3,11]],"date-time":"2024-03-11T17:50:10Z","timestamp":1710179410000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.healio.com\/doi\/10.3928\/1081597X-20240212-02"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,3]]},"references-count":70,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2024,3]]}},"alternative-id":["10.3928\/1081597X-20240212-02"],"URL":"https:\/\/doi.org\/10.3928\/1081597x-20240212-02","relation":{},"ISSN":["1081-597X"],"issn-type":[{"value":"1081-597X","type":"print"}],"subject":[],"published":{"date-parts":[[2024,3]]}}}