{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,13]],"date-time":"2026-11-13T09:07:50Z","timestamp":1794560870169,"version":"4.9.1"},"reference-count":36,"publisher":"SLACK, Inc.","issue":"6","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Refract Surg"],"published-print":{"date-parts":[[2024,6,1]]},"abstract":"<jats:sec>\n                    <jats:title>Purpose:<\/jats:title>\n                    <jats:p>To investigate the long-term visual quality and rotational stability after the implantation of Implantable Collamer Lens (ICL) and toric ICL (TICL) (STAAR Surgical) in patients with myopia older than 40 years.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>This study included 82 eyes of 41 patients older than 40 years with myopia who underwent ICL\/TICL V4c implantation. The refraction sphere, refraction cylinder, spherical equivalent (SE), uncorrected and corrected distance visual acuity, and anterior segmental parameters were measured preoperatively and at the 1-month, 3-month, and last follow-up visits at 33 to 58 months postoperatively (mean follow-up: 42.56 \u00b1 7.17 months). Wavefront aberrations and TICL rotation were measured using OPD-Scan III (Nidek Co Ltd) at the last follow-up visit.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      At the last follow-up visit, the overall safety and efficacy index were 1.22 \u00b1 0.26 and 0.88 \u00b1 0.34, respectively, without significant differences between the ICL and TICL groups. Postoperative refraction cylinder was \u22120.95 \u00b1 0.64 and \u22120.71 \u00b1 0.54 diopters in the ICL and TICL groups, respectively. The average vault was 467.44 \u00b1 231.98 \u00b5m. The average TICL rotation was 5.45 \u00b1 6.61 degrees, positively correlated with the preoperative anterior chamber volume (\n                      <jats:italic toggle=\"yes\">R<\/jats:italic>\n                      <jats:sup>2<\/jats:sup>\n                      = 0.1118,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = .026) and clockwise TICL alignment degree (\n                      <jats:italic toggle=\"yes\">R<\/jats:italic>\n                      <jats:sup>2<\/jats:sup>\n                      = 0.3110,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = .007) and negatively correlated with the 1-month vault (\n                      <jats:italic toggle=\"yes\">R<\/jats:italic>\n                      <jats:sup>2<\/jats:sup>\n                      = 0.1218,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = .008). There were no significant differences in the total, corneal, or internal aberrations and modulation transfer function AreaRatio between the ICL and TICL groups.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions:<\/jats:title>\n                    <jats:p>Both ICL and TICL presented satisfactory long-term safety, efficacy, and visual quality in patients older than 40 years. Postoperative TICL spontaneous rotation was within the manageable range in the long term.<\/jats:p>\n                    <jats:p>\n                      <jats:bold>\n                        [\n                        <jats:italic toggle=\"yes\">J Refract Surg<\/jats:italic>\n                        . 2024;40(6):e381\u2013e391.]\n                      <\/jats:bold>\n                    <\/jats:p>\n                  <\/jats:sec>","DOI":"10.3928\/1081597x-20240422-04","type":"journal-article","created":{"date-parts":[[2024,6,7]],"date-time":"2024-06-07T11:18:00Z","timestamp":1717759080000},"source":"Crossref","is-referenced-by-count":10,"title":["The Long-term Visual Quality and Rotational Stability After ICL\/TICL V4c Implantation in Individuals With High Myopia Older Than 40 Years"],"prefix":"10.3928","volume":"40","author":[{"given":"Yuhao","family":"Ye","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yijia","family":"Xu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zhe","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lingling","family":"Niu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wanru","family":"Shi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xiaoying","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xingtao","family":"Zhou","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jing","family":"Zhao","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"2308","reference":[{"key":"e_1_3_3_2_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2018.10.029"},{"key":"e_1_3_3_3_2","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0238399"},{"key":"e_1_3_3_4_2","doi-asserted-by":"publisher","DOI":"10.1136\/bjophthalmol-2021-319205"},{"key":"e_1_3_3_5_2","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0183335"},{"key":"e_1_3_3_6_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1442-9071.2010.02273.x"},{"key":"e_1_3_3_7_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20230512-03"},{"key":"e_1_3_3_8_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.preteyeres.2018.09.004"},{"key":"e_1_3_3_9_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.preteyeres.2017.04.001"},{"key":"e_1_3_3_10_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00417-017-3801-z"},{"key":"e_1_3_3_11_2","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.10-6447"},{"key":"e_1_3_3_12_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00417-021-05545-x"},{"key":"e_1_3_3_13_2","doi-asserted-by":"publisher","DOI":"10.1186\/s12886-016-0336-8"},{"key":"e_1_3_3_14_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20090915-08"},{"key":"e_1_3_3_15_2","doi-asserted-by":"publisher","DOI":"10.1038\/eye.2014.272"},{"key":"e_1_3_3_16_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20220411-01"},{"key":"e_1_3_3_17_2","doi-asserted-by":"publisher","DOI":"10.1186\/s12886-018-0805-3"},{"key":"e_1_3_3_18_2","doi-asserted-by":"publisher","DOI":"10.1080\/02713683.2021.2012202"},{"key":"e_1_3_3_19_2","doi-asserted-by":"publisher","DOI":"10.2147\/OPTH.S393422"},{"key":"e_1_3_3_20_2","doi-asserted-by":"publisher","DOI":"10.1007\/s10792-022-02328-z"},{"key":"e_1_3_3_21_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00417-021-05545-x"},{"key":"e_1_3_3_22_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2004.07.018"},{"key":"e_1_3_3_23_2","doi-asserted-by":"publisher","DOI":"10.1186\/s12886-022-02653-y"},{"key":"e_1_3_3_24_2","doi-asserted-by":"publisher","DOI":"10.1080\/02713683.2022.2159981"},{"key":"e_1_3_3_25_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00417-021-05449-w"},{"key":"e_1_3_3_26_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2004.12.057"},{"key":"e_1_3_3_27_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20180521-01"},{"key":"e_1_3_3_28_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2004.06.009"},{"issue":"4","key":"e_1_3_3_29_2","first-page":"459","article-title":"Outcomes and possible risk factors associated with axis alignment and rotational stability after implantation of the Toric implantable collamer lens for high myopic astigmatism","volume":"5","author":"Sheng XL","year":"2012","unstructured":"Sheng XL, Rong WN, Jia Q, . Outcomes and possible risk factors associated with axis alignment and rotational stability after implantation of the Toric implantable collamer lens for high myopic astigmatism. Int J Ophthalmol. 2012;5(4):459\u2013465. PMID:22937505","journal-title":"Int J Ophthalmol"},{"key":"e_1_3_3_30_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20090422-01"},{"key":"e_1_3_3_31_2","doi-asserted-by":"publisher","DOI":"10.1155\/2020\/3095302"},{"key":"e_1_3_3_32_2","doi-asserted-by":"publisher","DOI":"10.1097\/j.jcrs.0000000000000950"},{"key":"e_1_3_3_33_2","doi-asserted-by":"publisher","DOI":"10.1097\/j.jcrs.0000000000001140"},{"key":"e_1_3_3_34_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20220302-01a"},{"key":"e_1_3_3_35_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20111018-02"},{"key":"e_1_3_3_36_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20200210-02"},{"key":"e_1_3_3_37_2","doi-asserted-by":"publisher","DOI":"10.1111\/aos.14652"}],"container-title":["Journal of Refractive Surgery"],"original-title":[],"language":"en","deposited":{"date-parts":[[2026,3,31]],"date-time":"2026-03-31T13:40:49Z","timestamp":1774964449000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.healio.com\/doi\/10.3928\/1081597X-20240422-04"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,6,1]]},"references-count":36,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2024,6,1]]}},"alternative-id":["10.3928\/1081597X-20240422-04"],"URL":"https:\/\/doi.org\/10.3928\/1081597x-20240422-04","relation":{},"ISSN":["1081-597X"],"issn-type":[{"value":"1081-597X","type":"print"}],"subject":[],"published":{"date-parts":[[2024,6,1]]}}}