{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,19]],"date-time":"2026-11-19T18:01:51Z","timestamp":1795111311771,"version":"4.10.3"},"reference-count":20,"publisher":"SLACK, Inc.","issue":"8","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Refract Surg"],"published-print":{"date-parts":[[2024,8]]},"abstract":"<jats:sec>\n            <jats:title>Purpose:<\/jats:title>\n            <jats:p>To compare the outcomes of anterior chamber intraocular lens (AC-IOL) implantation versus the four-flanged scleral fixation technique in eyes with loss of capsular support during routine cataract surgery.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods:<\/jats:title>\n            <jats:p>This was a retrospective cohort study of all patients in whom an IOL was implanted either during or after short-term aphakia due to loss of capsular and sulcus support in a routine cataract surgery with at least 6 months of follow-up time between 2015 and 2023 in a tertiary medical center in Israel. Two different IOL implantation techniques were compared: the implantation of an angle-supported ACIOL and four-flanged scleral fixation. Main outcome measures included postoperative complications such as pseudophakic bullous keratopathy, loss of intraocular pressure control and glaucoma, IOL subluxation, and retinal detachment.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>\n              Sixty-five eyes of 65 patients were included in the study, 33 eyes in the AC-IOL group and 32 eyes in the flange group. Follow-up time was 29.92 \u00b1 20.02 months in the AC-IOL group and 20.17 \u00b1 15.56 months in the flange group (\n              <jats:italic>P<\/jats:italic>\n              = .087). Pseudophakic bullous keratopathy was observed in 10 (30.3%) patients in the AC-IOL group and in 1 (3.1%) patient in the flange group (\n              <jats:italic>P<\/jats:italic>\n              = .04). This association remained significant using survival analysis (\n              <jats:italic>P<\/jats:italic>\n              = .006). In 4 (12.1%) patients in the AC-IOL group, a glaucoma filtering procedure was performed to control the intraocular pressure compared with none in the flange group (\n              <jats:italic>P<\/jats:italic>\n              = .042).\n            <\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions:<\/jats:title>\n            <jats:p>In the setting of loss of capsular support during routine cataract surgery, four-flanged scleral fixation showed an overall lower rate of complications and significantly reduced rate of subsequent surgical interventions.<\/jats:p>\n            <jats:p>\n              <jats:bold>\n                [\n                <jats:italic>J Refract Surg<\/jats:italic>\n                . 2024;40(8):e520\u2013e526.]\n              <\/jats:bold>\n            <\/jats:p>\n          <\/jats:sec>","DOI":"10.3928\/1081597x-20240523-01","type":"journal-article","created":{"date-parts":[[2024,8,9]],"date-time":"2024-08-09T11:43:40Z","timestamp":1723203820000},"source":"Crossref","is-referenced-by-count":4,"title":["Anterior Chamber Intraocular Lens Implantation Versus Four-Flanged Scleral Fixation Technique for Patients With Loss of Capsular Support During Routine Cataract Surgery"],"prefix":"10.3928","volume":"40","author":[{"given":"Biana","family":"Dubinsky-Pertzov","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ori","family":"Mahler","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Asaf","family":"Shemer","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Idan","family":"Hecht","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Francis","family":"Simaan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Avner","family":"Belkin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Eran","family":"Pras","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Adi","family":"Einan-Lifshitz","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"2308","reference":[{"key":"e_1_3_2_2_2","doi-asserted-by":"publisher","DOI":"10.1136\/bjo.79.12.1133"},{"key":"e_1_3_2_3_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2020.03.005"},{"key":"e_1_3_2_4_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.survophthal.2005.06.010"},{"key":"e_1_3_2_5_2","doi-asserted-by":"publisher","DOI":"10.1155\/2020\/5967509"},{"key":"e_1_3_2_6_2","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.08-2778"},{"key":"e_1_3_2_7_2","doi-asserted-by":"publisher","DOI":"10.1097\/00055735-200102000-00009"},{"key":"e_1_3_2_8_2","doi-asserted-by":"publisher","DOI":"10.1097\/ICO.0000000000002185"},{"key":"e_1_3_2_9_2","doi-asserted-by":"publisher","DOI":"10.1097\/j.jcrs.0000000000000600"},{"key":"e_1_3_2_10_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20220919-01"},{"key":"e_1_3_2_11_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2013.01.019"},{"issue":"14","key":"e_1_3_2_12_2","first-page":"6216","article-title":"Severe loss of endothelial cell density and beginning corneal decompensation 6 years after implantation of I-CARE anterior-chamber angle-supported phakic intraocular lens","volume":"52","author":"Hofmann C","year":"2011","unstructured":"Hofmann C, Kohnen T. Severe loss of endothelial cell density and beginning corneal decompensation 6 years after implantation of I-CARE anterior-chamber angle-supported phakic intraocular lens. Invest Ophthalmol Vis Sci. 2011;52(14):6216.","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"e_1_3_2_13_2","doi-asserted-by":"publisher","DOI":"10.4103\/ojo.OJO_134_2016"},{"key":"e_1_3_2_14_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(02)02052-7"},{"key":"e_1_3_2_15_2","doi-asserted-by":"publisher","DOI":"10.1097\/01.ico.0000214225.98366.83"},{"key":"e_1_3_2_16_2","doi-asserted-by":"publisher","DOI":"10.1136\/bjophthalmol-2020-316711"},{"key":"e_1_3_2_17_2","doi-asserted-by":"publisher","DOI":"10.1177\/11206721211066390"},{"key":"e_1_3_2_18_2","doi-asserted-by":"publisher","DOI":"10.3928\/1542-8877-19930601-04"},{"key":"e_1_3_2_19_2","doi-asserted-by":"publisher","DOI":"10.1038\/eye.2017.261"},{"key":"e_1_3_2_20_2","doi-asserted-by":"publisher","DOI":"10.18240\/ijo.2016.03.26"},{"key":"e_1_3_2_21_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2016.06.018"}],"container-title":["Journal of Refractive Surgery"],"original-title":[],"language":"en","deposited":{"date-parts":[[2024,8,9]],"date-time":"2024-08-09T11:44:20Z","timestamp":1723203860000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.healio.com\/doi\/10.3928\/1081597X-20240523-01"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,8]]},"references-count":20,"journal-issue":{"issue":"8","published-print":{"date-parts":[[2024,8]]}},"alternative-id":["10.3928\/1081597X-20240523-01"],"URL":"https:\/\/doi.org\/10.3928\/1081597x-20240523-01","relation":{},"ISSN":["1081-597X"],"issn-type":[{"value":"1081-597X","type":"print"}],"subject":[],"published":{"date-parts":[[2024,8]]}}}