{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,8]],"date-time":"2026-10-08T05:22:57Z","timestamp":1791436977694,"version":"4.3.3"},"reference-count":45,"publisher":"SLACK, Inc.","issue":"9","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Refract Surg"],"published-print":{"date-parts":[[2024,9]]},"abstract":"<jats:sec>\n            <jats:title>Purpose:<\/jats:title>\n            <jats:p>To determine the misclassification rate of the keratoconus percentage (KISA%) index efficacy in eyes with progressive keratoconus.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods:<\/jats:title>\n            <jats:p>This was a retrospective case-control study of consecutive patients with confirmed progressive keratoconus and a contemporaneous normal control group with 1.00 diopters or greater regular astigmatism. Scheimpflug imaging (Pentacam HR) was obtained for all patients. KISA% index and inferior-superior (IS) values were obtained from the Pentacam topometric\/keratoconus staging map. Receiver operating characteristic curves were generated to determine the area under the receiver operating characteristic curve (AUROC), sensitivity, and specificity values.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>There were 160 eyes from 160 patients evaluated, including 80 eyes from 80 patients with progressive keratoconus and 80 eyes from 80 control patients. There were 20 eyes (25%) with progressive keratoconus misclassified by the KISA% index, with 16 eyes (20%) of the progressive keratoconus cohort classified as normal (ie, KISA% &lt; 60). There were 4 eyes (5%) with progressive keratoconus that would classify as having \u201cnormal topography\u201d using the published criteria for very asymmetric ectasia with normal topography of KISA% less than 60 and IS value less than 1.45. All controls had a KISA% index value of less than 15. The optimal cut-off value to distinguish cohorts was 15.31 (AUROC = 0.972, 93.75% sensitivity). KISA% index values of 60 and 100 achieved low sensitivity (80% and 73.75%, respectively).<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions:<\/jats:title>\n            <jats:p>The KISA% index misclassified a significant proportion of eyes with progressive keratoconus as normal. Although highly specific for clinical keratoconus, the KISA% index lacks sensitivity, does not effectively discriminate between normal and abnormal topography, and thus should not be used in large data analysis or artificial intelligence\u2013based modeling.<\/jats:p>\n            <jats:p>\n              <jats:bold>\n                [\n                <jats:italic>J Refract Surg<\/jats:italic>\n                . 2024;40(9):e614\u2013e624.]\n              <\/jats:bold>\n            <\/jats:p>\n          <\/jats:sec>","DOI":"10.3928\/1081597x-20240726-01","type":"journal-article","created":{"date-parts":[[2024,9,10]],"date-time":"2024-09-10T12:30:33Z","timestamp":1725971433000},"source":"Crossref","is-referenced-by-count":4,"title":["Misclassification of Eyes With Progressive Keratoconus Using the KISA% Index"],"prefix":"10.3928","volume":"40","author":[{"given":"Bassel","family":"Hammoud","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"suffix":"Jr","given":"William J.","family":"Dupps","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Giuliano","family":"Scarcelli","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"J. Bradley","family":"Randleman","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"2308","reference":[{"key":"e_1_3_2_2_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0039-6257(97)00119-7"},{"key":"e_1_3_2_3_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2022.11.027"},{"key":"e_1_3_2_4_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2020.08.020"},{"key":"e_1_3_2_5_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2016.12.015"},{"key":"e_1_3_2_6_2","doi-asserted-by":"publisher","DOI":"10.1136\/bjophthalmol-2017-311391"},{"key":"e_1_3_2_7_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2007.03.073"},{"key":"e_1_3_2_8_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0161-6420(02)01727-X"},{"issue":"6","key":"e_1_3_2_9_2","first-page":"2749","article-title":"Automated keratoconus screening with corneal topography analysis","volume":"35","author":"Maeda N","year":"1994","unstructured":"Maeda N, Klyce SD, Smolek MK, Thompson HW. Automated keratoconus screening with corneal topography analysis. Invest Ophthalmol Vis Sci. 1994;35(6):2749\u20132757. PMID:8188468","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"e_1_3_2_10_2","doi-asserted-by":"publisher","DOI":"10.1001\/archopht.1995.01100070044023"},{"key":"e_1_3_2_11_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081-597X-19950901-14"},{"key":"e_1_3_2_12_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2008.08.004"},{"key":"e_1_3_2_13_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2009.03.050"},{"key":"e_1_3_2_14_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20100218-01"},{"key":"e_1_3_2_15_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2006.06.025"},{"key":"e_1_3_2_16_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(99)00195-9"},{"key":"e_1_3_2_17_2","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.09-3689"},{"key":"e_1_3_2_18_2","doi-asserted-by":"publisher","DOI":"10.1097\/ICO.0000000000000568"},{"key":"e_1_3_2_19_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20170426-02"},{"key":"e_1_3_2_20_2","doi-asserted-by":"publisher","DOI":"10.1002\/jbio.201600106"},{"key":"e_1_3_2_21_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2018.06.020"},{"key":"e_1_3_2_22_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2023.10.011"},{"key":"e_1_3_2_23_2","doi-asserted-by":"publisher","DOI":"10.1136\/bjo.80.7.610"},{"key":"e_1_3_2_24_2","doi-asserted-by":"publisher","DOI":"10.1097\/01.opx.0000192350.01045.6f"},{"key":"e_1_3_2_25_2","doi-asserted-by":"publisher","DOI":"10.1097\/ICO.0000000000001194"},{"key":"e_1_3_2_26_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00347-011-2446-2"},{"key":"e_1_3_2_27_2","doi-asserted-by":"publisher","DOI":"10.1111\/aos.12590"},{"key":"e_1_3_2_28_2","doi-asserted-by":"publisher","DOI":"10.1097\/ICO.0000000000001537"},{"key":"e_1_3_2_29_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2022.12.016"},{"key":"e_1_3_2_30_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20181012-01"},{"key":"e_1_3_2_31_2","doi-asserted-by":"publisher","DOI":"10.1097\/ICO.0000000000003273"},{"key":"e_1_3_2_32_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20220601-01"},{"key":"e_1_3_2_33_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2018.08.005"},{"key":"e_1_3_2_34_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.survophthal.2021.08.004"},{"issue":"11","key":"e_1_3_2_35_2","first-page":"CD014911","article-title":"Artificial intelligence for detecting keratoconus","volume":"11","author":"Vandevenne MM","year":"2023","unstructured":"Vandevenne MM, Favuzza E, Veta M, . Artificial intelligence for detecting keratoconus. Cochrane Database Syst Rev. 2023;11(11):CD014911. PMID:37965960","journal-title":"Cochrane Database Syst Rev"},{"key":"e_1_3_2_36_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0002-9394(02)02220-1"},{"key":"e_1_3_2_37_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2017.03.052"},{"key":"e_1_3_2_38_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.survophthal.2015.04.002"},{"key":"e_1_3_2_39_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2003.06.020"},{"key":"e_1_3_2_40_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.exer.2007.06.016"},{"key":"e_1_3_2_41_2","doi-asserted-by":"publisher","DOI":"10.1002\/1096-8628(20000828)93:5<403::AIDAJMG11>3.0.CO;2-A"},{"key":"e_1_3_2_42_2","doi-asserted-by":"publisher","DOI":"10.1111\/aos.12389"},{"key":"e_1_3_2_43_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081-597X-20051101-15"},{"key":"e_1_3_2_44_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2007.12.033"},{"key":"e_1_3_2_45_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20170213-01"},{"key":"e_1_3_2_46_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2018.08.054"}],"container-title":["Journal of Refractive Surgery"],"original-title":[],"language":"en","deposited":{"date-parts":[[2024,9,10]],"date-time":"2024-09-10T12:31:20Z","timestamp":1725971480000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.healio.com\/doi\/10.3928\/1081597X-20240726-01"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,9]]},"references-count":45,"journal-issue":{"issue":"9","published-print":{"date-parts":[[2024,9]]}},"alternative-id":["10.3928\/1081597X-20240726-01"],"URL":"https:\/\/doi.org\/10.3928\/1081597x-20240726-01","relation":{},"ISSN":["1081-597X"],"issn-type":[{"value":"1081-597X","type":"print"}],"subject":[],"published":{"date-parts":[[2024,9]]}}}