{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2024,11,13]],"date-time":"2024-11-13T05:29:41Z","timestamp":1731475781311,"version":"3.28.0"},"reference-count":25,"publisher":"SLACK, Inc.","issue":"11","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Refract Surg"],"published-print":{"date-parts":[[2024,11]]},"abstract":"<jats:sec>\n            <jats:title>Purpose<\/jats:title>\n            <jats:p>To investigate the reasons for the removal and\/or exchange of posterior chamber phakic intraocular lenses (PCPIOLs) and the outcomes of these procedures.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods<\/jats:title>\n            <jats:p>In this retrospective study, PCPIOL implantations performed between January 2015 and June 2023 in a single center were reviewed. The study group consisted of the files of eyes with removed and\/or exchanged PCPIOL. Visual acuities, refraction errors, endothelial cell counts, and measurements of the vault before and after exchanges were recorded. Reasons for removal and\/or exchange were evaluated. The tuck-and-pull technique was used in all explantations.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results<\/jats:title>\n            <jats:p>\n              Twenty-three of 1,490 eyes with PCPIOL implantation required removal and\/or exchange. Of the explanted eyes, 17 were implanted with PCPIOLs for myopia (1.21% of all myopic corrections) and 6 were implanted with PCPIOLs for hyperopia (6.59% of all hyperopic corrections). The most common reason for removal and\/or exchanges after implantation was inappropriate vault (10 of the 23 total removals and\/or exchanges), followed by cataract development (7 of the 23 total removals and\/or exchanges). A comparison of the biometric characteristics of eyes with PCPIOL removal and\/or exchange due to inappropriate vault with other PCPIOL implantations showed that anterior chamber depth, PCPIOL length, and white-to-white distance were significantly higher in the group of explanted eyes (\n              <jats:italic>P<\/jats:italic>\n              &lt; .05). All eyes with high vault in myopic patients had a 13.2- or 13.7-mm length PCPIOL.\n            <\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions<\/jats:title>\n            <jats:p>The main reason for PCPIOL removal and\/or exchange is vault values outside the ideal limits and cataract development. Before ordering 13.2- and 13.7-mm long PCPIOLs, biometric data of both eyes and recommended PCPIOL sizes should be carefully reviewed.<\/jats:p>\n            <jats:p>\n              <jats:bold>\n                [\n                <jats:italic>J Refract Surg<\/jats:italic>\n                . 2024;40(11):e797\u2013e803.]\n              <\/jats:bold>\n            <\/jats:p>\n          <\/jats:sec>","DOI":"10.3928\/1081597x-20240913-03","type":"journal-article","created":{"date-parts":[[2024,11,12]],"date-time":"2024-11-12T15:26:25Z","timestamp":1731425185000},"source":"Crossref","is-referenced-by-count":0,"title":["Reasons for Explantations of Posterior Chamber Phakic Intraocular Lenses in 1,490 Eyes"],"prefix":"10.3928","volume":"40","author":[{"given":"Efekan","family":"Coskunseven","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Belma","family":"Kayhan","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"2308","reference":[{"key":"e_1_3_3_2_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2006.05.057"},{"key":"e_1_3_3_3_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2006.09.029"},{"key":"e_1_3_3_4_2","doi-asserted-by":"publisher","DOI":"10.1097\/ICU.0000000000000870"},{"key":"e_1_3_3_5_2","doi-asserted-by":"publisher","DOI":"10.2147\/OPTH.S111620"},{"key":"e_1_3_3_6_2","doi-asserted-by":"publisher","DOI":"10.4103\/ijo.IJO_652_21"},{"key":"e_1_3_3_7_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2014.06.036"},{"key":"e_1_3_3_8_2","doi-asserted-by":"publisher","DOI":"10.4103\/0974-9233.194076"},{"key":"e_1_3_3_9_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081-597X-20070401-08"},{"key":"e_1_3_3_10_2","doi-asserted-by":"publisher","DOI":"10.1186\/s12886-018-0783-5"},{"key":"e_1_3_3_11_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2011.06.031"},{"key":"e_1_3_3_12_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20220302-01"},{"key":"e_1_3_3_13_2","doi-asserted-by":"publisher","DOI":"10.1186\/s12886-022-02583-9"},{"key":"e_1_3_3_14_2","doi-asserted-by":"publisher","DOI":"10.1097\/j.jcrs.0000000000000134"},{"key":"e_1_3_3_15_2","doi-asserted-by":"publisher","DOI":"10.1097\/j.jcrs.0000000000001079"},{"key":"e_1_3_3_16_2","doi-asserted-by":"publisher","DOI":"10.1186\/s12886-023-02814-7"},{"key":"e_1_3_3_17_2","doi-asserted-by":"publisher","DOI":"10.1136\/bcr-2020-238300"},{"key":"e_1_3_3_18_2","doi-asserted-by":"publisher","DOI":"10.1155\/2021\/6641475"},{"key":"e_1_3_3_19_2","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-020-78661-z"},{"key":"e_1_3_3_20_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcjo.2017.11.018"},{"key":"e_1_3_3_21_2","doi-asserted-by":"publisher","DOI":"10.1097\/MD.0000000000003270"},{"key":"e_1_3_3_22_2","doi-asserted-by":"publisher","DOI":"10.2147\/OPTH.S188785"},{"key":"e_1_3_3_23_2","doi-asserted-by":"publisher","DOI":"10.5301\/ejo.5000818"},{"key":"e_1_3_3_24_2","doi-asserted-by":"publisher","DOI":"10.1097\/j.jcrs.0000000000000119"},{"key":"e_1_3_3_25_2","doi-asserted-by":"publisher","DOI":"10.1097\/j.jcrs.0000000000000915"},{"key":"e_1_3_3_26_2","doi-asserted-by":"publisher","DOI":"10.1097\/j.jcrs.0000000000001099"}],"container-title":["Journal of Refractive Surgery"],"original-title":[],"language":"en","deposited":{"date-parts":[[2024,11,12]],"date-time":"2024-11-12T15:27:12Z","timestamp":1731425232000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.healio.com\/doi\/10.3928\/1081597X-20240913-03"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,11]]},"references-count":25,"journal-issue":{"issue":"11","published-print":{"date-parts":[[2024,11]]}},"alternative-id":["10.3928\/1081597X-20240913-03"],"URL":"https:\/\/doi.org\/10.3928\/1081597x-20240913-03","relation":{},"ISSN":["1081-597X"],"issn-type":[{"value":"1081-597X","type":"print"}],"subject":[],"published":{"date-parts":[[2024,11]]}}}