{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,29]],"date-time":"2026-06-29T10:47:49Z","timestamp":1782730069797,"version":"3.54.5"},"reference-count":21,"publisher":"SLACK, Inc.","issue":"11","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Refract Surg"],"published-print":{"date-parts":[[2024,11]]},"abstract":"<jats:sec>\n            <jats:title>Purpose<\/jats:title>\n            <jats:p>To demonstrate the non-inferiority of a stand-alone unidirectional airflow system, the SurgiCube (Surgi-Cube International BV), for cataract surgery compared to a conventional operating theater (OT).<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods<\/jats:title>\n            <jats:p>This was a retrospective and comparative cross-sectional study conducted at the Rothschild Foundation, Paris, France. All patients who underwent cataract surgery using the SurgiCube between February 2020 and February 2023 were included and compared to a separate group of patients with cataract surgery performed in a conventional OT and under topical anesthesia during the same period. Patients with less than 1 month of follow-up after surgery were excluded. We collected relevant information from the patient's medical records. Main outcome measures, incidence of endophthalmitis, intraoperative and postoperative complication incidence, 1-month logarithm of minimum angle of resolution (logMAR) visual acuity and intraocular pressure, and operating times were analyzed.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results<\/jats:title>\n            <jats:p>\n              A total of 1,901 eyes in the SurgiCube group were compared to 5,474 eyes in the OT group. The occurrence of endophthalmitis was 0.05% (n = 1) in the SurgiCube group versus 0.07% (n = 4) in the OT group (\n              <jats:italic>P<\/jats:italic>\n              = 1.00; odds ratio = 0.72 [95% CI = 0.01 to 7.28]). The percentage of procedures with at least one perioperative complication was 2.6% in the SurgiCube group and 2.7% in the OT group (\n              <jats:italic>P<\/jats:italic>\n              = .87; odds ratio = 0.96 [95% CI = 0.68 to 1.34]). The percentage of procedures with a postoperative complication was 6.31% in the SurgiCube group and 6.6% in the OT group (\n              <jats:italic>P<\/jats:italic>\n              = .59; odds ratio = 0.94 [95% CI = 0.75 to 1.17]. Average visual acuity at 30 days was 0.04 logMAR in the SurgiCube group and 0.07 logMAR in the OT group (\n              <jats:italic>P<\/jats:italic>\n              = .62). The average operating times were 16.8 and 19.7 minutes for the SurgiCube and OT groups, respectively (\n              <jats:italic>P<\/jats:italic>\n              &lt; .001). The average occupation room times were 26.2 and 32.3 minutes for the SurgiCube and OT groups, respectively (\n              <jats:italic>P<\/jats:italic>\n              &lt; .001).\n            <\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions<\/jats:title>\n            <jats:p>Cataract surgery in the SurgiCube seems to be non-inferior to cataract surgery in a conventional OT.<\/jats:p>\n            <jats:p>\n              <jats:bold>\n                [\n                <jats:italic>J Refract Surg<\/jats:italic>\n                . 2024;40(11):e884\u2013e891.]\n              <\/jats:bold>\n            <\/jats:p>\n          <\/jats:sec>","DOI":"10.3928\/1081597x-20241009-01","type":"journal-article","created":{"date-parts":[[2024,11,12]],"date-time":"2024-11-12T15:26:25Z","timestamp":1731425185000},"source":"Crossref","is-referenced-by-count":1,"title":["Non-inferiority of Cataract Surgery in a Stand-Alone Unidirectional Airflow System Versus in a Conventional Operating Room: A Retrospective Study"],"prefix":"10.3928","volume":"40","author":[{"given":"Sarah","family":"Partouche","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Filippo","family":"Fabro","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Artus","family":"Arnaud","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lucile","family":"Senicourt","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Damien","family":"Gatinel","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christophe","family":"Panthier","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"2308","reference":[{"key":"e_1_3_2_2_2","doi-asserted-by":"publisher","DOI":"10.1016\/S2214-109X(20)30489-7"},{"key":"e_1_3_2_3_2","doi-asserted-by":"publisher","DOI":"10.21037\/atm-2020-rcs-16"},{"key":"e_1_3_2_4_2","doi-asserted-by":"publisher","DOI":"10.1001\/jamaophthalmol.2017.5101"},{"key":"e_1_3_2_5_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jhin.2018.01.007"},{"key":"e_1_3_2_6_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2015.12.020"},{"key":"e_1_3_2_7_2","doi-asserted-by":"publisher","DOI":"10.1097\/j.jcrs.0000000000001231"},{"key":"e_1_3_2_8_2","unstructured":"SurgiCube International BV. Clean air SurgiCube airborne infections. April 10 2022. https:\/\/surgicube.com\/"},{"key":"e_1_3_2_9_2","unstructured":"AFNOR. NF S90-351 \u00c9tablissements de sant\u00e9\u2014Zones \u00e0 environnement ma\u00eetris\u00e9\u2014Exigences relatives \u00e0 la ma\u00eetrise de la contamination a\u00e9roport\u00e9e. April 2013."},{"key":"e_1_3_2_10_2","unstructured":"SurgiCube International BV. SurgiCube Clinical Tests The use of the SurgiCube\u00ae over critical zones and instruments to reduce air-borne contamination at intraocular ophthalmic surgeries Oogartsen Praktijk Delfland Eye clinic Delft The Netherlands. August & September 2016. https:\/\/surgicube.com\/wp-content\/uploads\/2017\/02\/2.6_Clinical-Info_SurgiCube-Clinical-Tests.pdf"},{"key":"e_1_3_2_11_2","doi-asserted-by":"publisher","DOI":"10.1155\/2020\/3680406"},{"key":"e_1_3_2_12_2","doi-asserted-by":"publisher","DOI":"10.1097\/j.jcrs.0000000000000613"},{"key":"e_1_3_2_13_2","doi-asserted-by":"publisher","DOI":"10.1007\/s10195-011-0168-5"},{"key":"e_1_3_2_14_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jhin.2018.03.024"},{"key":"e_1_3_2_15_2","doi-asserted-by":"publisher","DOI":"10.3389\/fmed.2023.987505"},{"key":"e_1_3_2_16_2","doi-asserted-by":"publisher","DOI":"10.1038\/s41433-022-02317-7"},{"key":"e_1_3_2_17_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2013.11.002"},{"key":"e_1_3_2_18_2","unstructured":"European Society of Cataract and Refractive Surgery. Annual Report 2020\u20132021 based on data from the European Registry of Quality Outcomes for Cataract and Refractive Surgery. 2021. https:\/\/www.escrs.org\/media\/3uhkvz2n\/eurequo_annual-report_2020_21_final.pdf"},{"key":"e_1_3_2_19_2","unstructured":"National Health Service. Ophthalmology Getting It Right the First Time Programme National Specialty Report. December 2019. https:\/\/gettingitrightfirsttime.co.uk\/surgical_specialties\/ophthalmology\/"},{"key":"e_1_3_2_20_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2019.01.002"},{"key":"e_1_3_2_21_2","doi-asserted-by":"publisher","DOI":"10.1097\/ICO.0000000000001149"},{"key":"e_1_3_2_22_2","unstructured":"World Health Organization. Report of the 2030 targets on effective coverage of eye care. October 12 2022. https:\/\/www.who.int\/publications-detail-redirect\/9789240058002"}],"container-title":["Journal of Refractive Surgery"],"original-title":[],"language":"en","deposited":{"date-parts":[[2024,11,12]],"date-time":"2024-11-12T15:27:10Z","timestamp":1731425230000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.healio.com\/doi\/10.3928\/1081597X-20241009-01"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,11]]},"references-count":21,"journal-issue":{"issue":"11","published-print":{"date-parts":[[2024,11]]}},"alternative-id":["10.3928\/1081597X-20241009-01"],"URL":"https:\/\/doi.org\/10.3928\/1081597x-20241009-01","relation":{},"ISSN":["1081-597X"],"issn-type":[{"value":"1081-597X","type":"print"}],"subject":[],"published":{"date-parts":[[2024,11]]}}}