{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,9]],"date-time":"2026-11-09T09:59:23Z","timestamp":1794218363442,"version":"4.8.0"},"reference-count":32,"publisher":"SLACK, Inc.","issue":"2","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Refract Surg"],"published-print":{"date-parts":[[2025,2]]},"abstract":"<jats:sec>\n            <jats:title>Purpose<\/jats:title>\n            <jats:p>To compare clinical outcomes for patients implanted with either FineVision HP or FineVision Triumf intraocular lenses (IOL) (Beaver-Visitec International, Inc) following cataract surgery.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods<\/jats:title>\n            <jats:p>Twenty-six patients bilaterally implanted with the HP IOL and 27 patients with the Triumf IOL were followed up for 6 months in a prospective randomized study. Refraction, uncorrected and corrected distance visual acuity (CDVA), uncorrected and distance-corrected intermediate visual acuity (DCIVA), and uncorrected and distance-corrected near visual acuity (DCNVA) were evaluated. Defocus curves and contrast sensitivity were also measured. Patient-reported outcomes were assessed using the National Eye Institute Visual Function Questionnaire 25, and adverse events were registered.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results<\/jats:title>\n            <jats:p>\n              Ninety-four percent of the eyes in both groups were within \u00b11.00 diopter (D) of spherical equivalent. All of the patients had 20\/20 or better binocular CDVA in both groups and 96% and 100% had 20\/25 or better binocular CDIVA in the Triumf and HP IOL groups, respectively, being reduced to 32% and 91.7% for DCNVA, respectively. Differences between groups were statistically significant from \u22122.00 to \u22124.50 D with better visual acuity outcomes for the HP IOL group (\n              <jats:italic>P<\/jats:italic>\n              &lt; .01). Better monocular photopic contrast sensitivity was found for the Triumf IOL group at 12 and 18 cycles per degree (\n              <jats:italic>P<\/jats:italic>\n              &lt; .01). There was a statistically significant increase of the overall composite score in both groups before and after surgery (\n              <jats:italic>P<\/jats:italic>\n              &lt; .001). Spectacle independence was similar between groups for distance and intermediate vision but higher for the HP IOL for near vision (96% versus 75%). There were no adverse events related to the IOLs.\n            <\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions<\/jats:title>\n            <jats:p>Both IOLs showed good and comparable distance and intermediate visual acuities but near vision was better for the HP IOL. This model provided higher spectacle independence for near vision.<\/jats:p>\n            <jats:p>\n              <jats:bold>\n                [\n                <jats:italic>J Refract Surg<\/jats:italic>\n                . 2025;41(3):e102\u2013e113.]\n              <\/jats:bold>\n            <\/jats:p>\n          <\/jats:sec>","DOI":"10.3928\/1081597x-20241113-01","type":"journal-article","created":{"date-parts":[[2025,2,12]],"date-time":"2025-02-12T19:54:31Z","timestamp":1739390071000},"source":"Crossref","is-referenced-by-count":4,"title":["Prospective Comparison of Clinical Outcomes After Bilateral Implantation of Diffractive Trifocal Extended Depth-of-Focus and Diffractive Trifocal Hydrophobic Intraocular Lenses"],"prefix":"10.3928","volume":"41","author":[{"given":"Zolt\u00e1n Z.","family":"Nagy","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Peter","family":"Dorman","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Szilard","family":"Szalczer","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Huba","family":"Kiss","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"2308","reference":[{"key":"e_1_3_2_2_2","doi-asserted-by":"publisher","DOI":"10.1001\/jamaophthalmol.2022.3667"},{"key":"e_1_3_2_3_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2009.02.036"},{"key":"e_1_3_2_4_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2007.12.038"},{"key":"e_1_3_2_5_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2010.07.035"},{"key":"e_1_3_2_6_2","doi-asserted-by":"publisher","DOI":"10.1097\/APO.0000000000000296"},{"key":"e_1_3_2_7_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2023.01.024"},{"key":"e_1_3_2_8_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2018.11.034"},{"key":"e_1_3_2_9_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20200930-01"},{"key":"e_1_3_2_10_2","doi-asserted-by":"publisher","DOI":"10.2147\/OPTH.S273641"},{"key":"e_1_3_2_11_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20211209-02"},{"key":"e_1_3_2_12_2","doi-asserted-by":"publisher","DOI":"10.1080\/02713683.2021.1946563"},{"key":"e_1_3_2_13_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20220516-02"},{"key":"e_1_3_2_14_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00417-022-05710-w"},{"key":"e_1_3_2_15_2","doi-asserted-by":"publisher","DOI":"10.1007\/s40123-022-00634-4"},{"key":"e_1_3_2_16_2","doi-asserted-by":"publisher","DOI":"10.1038\/s41433-023-02682-x"},{"key":"e_1_3_2_17_2","doi-asserted-by":"publisher","DOI":"10.2147\/OPTH.S453565"},{"key":"e_1_3_2_18_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2019.06.002"},{"key":"e_1_3_2_19_2","doi-asserted-by":"publisher","DOI":"10.3390\/jcm12072523"},{"key":"e_1_3_2_20_2","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-023-41634-z"},{"key":"e_1_3_2_21_2","doi-asserted-by":"publisher","DOI":"10.1097\/j.jcrs.0000000000001398"},{"key":"e_1_3_2_22_2","doi-asserted-by":"publisher","DOI":"10.1001\/archopht.119.7.1050"},{"key":"e_1_3_2_23_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20190618-01"},{"key":"e_1_3_2_24_2","doi-asserted-by":"publisher","DOI":"10.1186\/s12886-019-1204-0"},{"key":"e_1_3_2_25_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20170217-01"},{"key":"e_1_3_2_26_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2011.05.047"},{"key":"e_1_3_2_27_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2018.01.031"},{"key":"e_1_3_2_28_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20090301-07"},{"key":"e_1_3_2_29_2","doi-asserted-by":"publisher","DOI":"10.1097\/ICL.0b013e318232e32d"},{"key":"e_1_3_2_30_2","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.11-9155"},{"key":"e_1_3_2_31_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2010.11.043"},{"key":"e_1_3_2_32_2","doi-asserted-by":"publisher","DOI":"10.1097\/j.jcrs.0000000000000274"},{"key":"e_1_3_2_33_2","doi-asserted-by":"crossref","unstructured":"Mangione CM; National Eye Institute. The National Eye Institute 25-Item Visual Function Questionnaire (VFQ-25) 2000 version. https:\/\/www.nei.nih.gov\/learn-about-eye-health\/out-reach-resources\/outreach-materials\/visual-function-questionnaire-25","DOI":"10.1037\/t08622-000"}],"container-title":["Journal of Refractive Surgery"],"original-title":[],"language":"en","deposited":{"date-parts":[[2025,2,12]],"date-time":"2025-02-12T19:54:44Z","timestamp":1739390084000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.healio.com\/doi\/10.3928\/1081597X-20241113-01"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,2]]},"references-count":32,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2025,2]]}},"alternative-id":["10.3928\/1081597X-20241113-01"],"URL":"https:\/\/doi.org\/10.3928\/1081597x-20241113-01","relation":{},"ISSN":["1081-597X"],"issn-type":[{"value":"1081-597X","type":"print"}],"subject":[],"published":{"date-parts":[[2025,2]]}}}