{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,4,8]],"date-time":"2025-04-08T12:40:10Z","timestamp":1744116010494,"version":"3.40.3"},"reference-count":38,"publisher":"SLACK, Inc.","issue":"4","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Refract Surg"],"published-print":{"date-parts":[[2025,4]]},"abstract":"<jats:sec>\n            <jats:title>Purpose<\/jats:title>\n            <jats:p>To characterize the accommodative function and optical quality in high and moderate myopia after the implantation of a phakic intraocular lens implantable collamer lens (ICL).<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods<\/jats:title>\n            <jats:p>This was a prospective observational study of 20 myopic patients undergoing bilateral ICL implantation with a mean spherical equivalent (SE) of \u22127.44 diopters (D) (range: \u22124.37 to \u221212.00 D). Amplitude of accommodation, subjective accommodative response, optical quality parameters including modulation transfer function cut-off, Objective Scatter Index, and Strehl ratio, and objective accommodative response with a double-pass system (HD Analyzer; Visiometrics SL) were assessed before surgery and 1 month postoperatively.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results<\/jats:title>\n            <jats:p>\n              Mean residual refractive error improved to 0.20 \u00b1 0.19 D (\n              <jats:italic>P<\/jats:italic>\n              &lt; .001) at 1 month postoperatively compared to preoperatively. Amplitude of accommodation decreased significantly by 1.65 D (\n              <jats:italic>P<\/jats:italic>\n              &lt; .001) from 7.65 \u00b1 1.33 D at baseline to 6.00 \u00b1 0.95 D at 1 month after ICL implantation. However, no significant changes were found in accommodative response or in the optical quality parameters of modulation transfer function cut-off, Objective Scatter Index, Strehl ratio, and objective accommodative response with HD Analyzer between preoperatively and 1-month postoperative follow-up (\n              <jats:italic>P<\/jats:italic>\n              &gt; .05).\n            <\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions<\/jats:title>\n            <jats:p>ICL implantation in healthy patients with moderate to high myopia does not significantly alter accommodative function, as measured by subjective or objective methods, or optical quality parameters, except for a non-clinically relevant decrease in amplitude of accommodation.<\/jats:p>\n            <jats:p>\n              <jats:bold>\n                [\n                <jats:italic>J Refract Surg<\/jats:italic>\n                . 2025;41(4):e325\u2013e332.]\n              <\/jats:bold>\n            <\/jats:p>\n          <\/jats:sec>","DOI":"10.3928\/1081597x-20250221-01","type":"journal-article","created":{"date-parts":[[2025,4,8]],"date-time":"2025-04-08T12:02:05Z","timestamp":1744113725000},"source":"Crossref","is-referenced-by-count":0,"title":["Analysis of Accommodation and Optical Quality After Myopia Surgery With Phakic Intraocular Lens Implantation"],"prefix":"10.3928","volume":"41","author":[{"given":"Esther","family":"L\u00f3pez-Artero","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Nuria","family":"Garz\u00f3n","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Francisco","family":"Poyales","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Blanca","family":"Poyales","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ricardo","family":"P\u00e9rez-Izquierdo","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mar\u00eda","family":"Garc\u00eda-Montero","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"2308","reference":[{"key":"e_1_3_2_2_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2016.01.006"},{"key":"e_1_3_2_3_2","doi-asserted-by":"publisher","DOI":"10.1136\/bjophthalmol-2021-319205"},{"key":"e_1_3_2_4_2","doi-asserted-by":"publisher","DOI":"10.1111\/aos.14599"},{"key":"e_1_3_2_5_2","doi-asserted-by":"publisher","DOI":"10.1177\/11206721211012861"},{"key":"e_1_3_2_6_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1475-1313.2007.00529.x"},{"key":"e_1_3_2_7_2","doi-asserted-by":"publisher","DOI":"10.4103\/0301-4738.16173"},{"key":"e_1_3_2_8_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1475-1313.2007.00479.x"},{"key":"e_1_3_2_9_2","doi-asserted-by":"publisher","DOI":"10.1186\/s12886-021-02217-6"},{"key":"e_1_3_2_10_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2008.05.049"},{"key":"e_1_3_2_11_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.optom.2019.08.001"},{"key":"e_1_3_2_12_2","doi-asserted-by":"publisher","DOI":"10.1111\/aos.13891"},{"key":"e_1_3_2_13_2","volume-title":"Clinical Management of Binocular Vision: Heterophoric, Accommodative, and Eye Movement Disorders","author":"Scheiman M","year":"2013","unstructured":"Scheiman M. Clinical Management of Binocular Vision: Heterophoric, Accommodative, and Eye Movement Disorders. Lippincott Williams & Wilkins; 2013."},{"key":"e_1_3_2_14_2","doi-asserted-by":"publisher","DOI":"10.1097\/MD.0000000000016434"},{"key":"e_1_3_2_15_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.visres.2012.03.021"},{"key":"e_1_3_2_16_2","doi-asserted-by":"publisher","DOI":"10.1111\/opo.12009"},{"key":"e_1_3_2_17_2","doi-asserted-by":"publisher","DOI":"10.1177\/11206721221128993"},{"key":"e_1_3_2_18_2","doi-asserted-by":"publisher","DOI":"10.1155\/2018\/8678352"},{"key":"e_1_3_2_19_2","doi-asserted-by":"publisher","DOI":"10.3390\/ijerph19116716"},{"issue":"10","key":"e_1_3_2_20_2","first-page":"20411","article-title":"Accommodation after an implantable collamer lens implantation in high myopia patients","volume":"9","author":"Tang Y","year":"2016","unstructured":"Tang Y, Ye J. Accommodation after an implantable collamer lens implantation in high myopia patients. Int J Clin Exp Med. 2016;9(10):20411\u201320417.","journal-title":"Int J Clin Exp Med"},{"key":"e_1_3_2_21_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20220919-02"},{"key":"e_1_3_2_22_2","doi-asserted-by":"publisher","DOI":"10.1080\/02713683.2019.1701690"},{"key":"e_1_3_2_23_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2011.07.001"},{"key":"e_1_3_2_24_2","doi-asserted-by":"publisher","DOI":"10.1007\/s11596-008-0524-8"},{"key":"e_1_3_2_25_2","doi-asserted-by":"publisher","DOI":"10.1186\/s12886-016-0352-8"},{"key":"e_1_3_2_26_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00417-010-1570-z"},{"key":"e_1_3_2_27_2","doi-asserted-by":"publisher","DOI":"10.1111\/cxo.12884"},{"key":"e_1_3_2_28_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00417-008-0938-9"},{"key":"e_1_3_2_29_2","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0066846"},{"key":"e_1_3_2_30_2","doi-asserted-by":"publisher","DOI":"10.1186\/s12886-020-01482-1"},{"key":"e_1_3_2_31_2","doi-asserted-by":"publisher","DOI":"10.1186\/s12886-018-0805-3"},{"key":"e_1_3_2_32_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2009.07.033"},{"key":"e_1_3_2_33_2","doi-asserted-by":"publisher","DOI":"10.1097\/OPX.0b013e3181ea1ad3"},{"key":"e_1_3_2_34_2","doi-asserted-by":"publisher","DOI":"10.1111\/opo.12038"},{"key":"e_1_3_2_35_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(03)00667-9"},{"key":"e_1_3_2_36_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.optom.2019.05.002"},{"key":"e_1_3_2_37_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.visres.2005.06.009"},{"key":"e_1_3_2_38_2","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0016823"},{"key":"e_1_3_2_39_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.optom.2020.06.004"}],"container-title":["Journal of Refractive Surgery"],"original-title":[],"language":"en","deposited":{"date-parts":[[2025,4,8]],"date-time":"2025-04-08T12:02:13Z","timestamp":1744113733000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.healio.com\/doi\/10.3928\/1081597X-20250221-01"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,4]]},"references-count":38,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2025,4]]}},"alternative-id":["10.3928\/1081597X-20250221-01"],"URL":"https:\/\/doi.org\/10.3928\/1081597x-20250221-01","relation":{},"ISSN":["1081-597X"],"issn-type":[{"value":"1081-597X","type":"print"}],"subject":[],"published":{"date-parts":[[2025,4]]}}}