{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,6,10]],"date-time":"2025-06-10T04:02:27Z","timestamp":1749528147744,"version":"3.41.0"},"reference-count":35,"publisher":"SLACK, Inc.","issue":"6","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Refract Surg"],"published-print":{"date-parts":[[2025,6]]},"abstract":"<jats:sec>\n            <jats:title>Purpose<\/jats:title>\n            <jats:p>To assess the feasibility and biocompatibility of a novel approach for preserving small incision lenticule extraction (SMILE) surgery-derived lenticules by integrating decellularization and lyophilization techniques.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods<\/jats:title>\n            <jats:p>\n              A total of 72 lenticules were divided into two distinct groups: the lyophilized decellularized storage group, which underwent treatment with Triton X-100 and sodium dodecyl sulfate, followed by freeze-drying and storage at \u221220\u00b0C for 24 hours; and the control group, which was stored in a sterile plastic vial at room temperature after extraction. Comprehensive analyses, including scanning electron and transmission electron microscopy, hematoxylin\u2013eosin staining, transmittance measurements, and live\/dead staining, were conducted on all lenticules to evaluate their preserved properties. SPSS v20.0 software (SPSS, Inc) was used for statistical analysis of quantitative data, and a\n              <jats:italic toggle=\"yes\">P<\/jats:italic>\n              value less than .05 was considered statistically significant.\n            <\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results<\/jats:title>\n            <jats:p>\n              Histomorphology observed that the lyophilized decellularized lenticules effectively removed cellular components while preserving the structural regularity and integrity of the collagen fibers. After rehydration, the lenticules exhibited central thickening and peripheral thinning. The optical transmittance of all rehydrated lyophilized decellularized lenticules was significantly higher than that of lyophilized ones (all\n              <jats:italic toggle=\"yes\">P<\/jats:italic>\n              &lt; .05), but still lower than that of fresh lenticules (all\n              <jats:italic toggle=\"yes\">P<\/jats:italic>\n              &lt; .05). After 20 to 30 minutes of rehydration, the optical transmittance of the lenticules exceeded 80%, and both weight and optical transmittance stabilized (all\n              <jats:italic toggle=\"yes\">P<\/jats:italic>\n              &gt; .05). Furthermore, in vitro biocompatibility testing revealed relatively good morphology and comparable quantity of human keratocytes, with no detection of dead cells.\n            <\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions<\/jats:title>\n            <jats:p>Lyophilized decellularized storage of SMILE-derived lenticules effectively preserved the tissue morphology, optical transparency, and biocompatibility, suggesting potential for clinical application.<\/jats:p>\n            <jats:p>\n              <jats:bold>\n                [\n                <jats:italic toggle=\"yes\">J Refract Surg<\/jats:italic>\n                . 2025;41(6):e542\u2013e550.]\n              <\/jats:bold>\n            <\/jats:p>\n          <\/jats:sec>","DOI":"10.3928\/1081597x-20250417-04","type":"journal-article","created":{"date-parts":[[2025,6,9]],"date-time":"2025-06-09T12:55:02Z","timestamp":1749473702000},"source":"Crossref","is-referenced-by-count":0,"title":["A Pilot Study of Lyophilized Decellularized Storage of SMILE-Derived Lenticules"],"prefix":"10.3928","volume":"41","author":[{"given":"Yiwen","family":"Fan","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xiaojun","family":"Hu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xingtao","family":"Zhou","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Meiyan","family":"Li","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"2308","reference":[{"key":"e_1_3_2_2_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2016.01.006"},{"key":"e_1_3_2_3_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0140-6736(18)33209-4"},{"key":"e_1_3_2_4_2","doi-asserted-by":"publisher","DOI":"10.1136\/bjo.2009.174284"},{"key":"e_1_3_2_5_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.preteyeres.2019.100780"},{"key":"e_1_3_2_6_2","doi-asserted-by":"publisher","DOI":"10.1097\/ICO.0000000000000276"},{"key":"e_1_3_2_7_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20170111-03"},{"key":"e_1_3_2_8_2","doi-asserted-by":"publisher","DOI":"10.5507\/bp.2023.004"},{"key":"e_1_3_2_9_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2015.04.007"},{"key":"e_1_3_2_10_2","doi-asserted-by":"publisher","DOI":"10.1007\/s10561-021-09990-0"},{"issue":"2","key":"e_1_3_2_11_2","first-page":"55","article-title":"A review of methods for storage of corneas for keratoplasty","volume":"43","author":"Basu PK","year":"1995","unstructured":"Basu PK. A review of methods for storage of corneas for keratoplasty. Indian J Ophthalmol. 1995;43(2):55\u201358. PMID:8818310","journal-title":"Indian J Ophthalmol"},{"key":"e_1_3_2_12_2","first-page":"3437","article-title":"Cornea lenticule viability and structural integrity after refractive lenticule extraction (ReLEx) and cryopreservation","volume":"17","author":"Mohamed-Noriega K","year":"2011","unstructured":"Mohamed-Noriega K, Toh KP, Poh R, . Cornea lenticule viability and structural integrity after refractive lenticule extraction (ReLEx) and cryopreservation. Mol Vis. 2011;17:3437\u20133449. PMID:22219639","journal-title":"Mol Vis"},{"key":"e_1_3_2_13_2","doi-asserted-by":"publisher","DOI":"10.1136\/bjophthalmol-2015-306944"},{"key":"e_1_3_2_14_2","doi-asserted-by":"publisher","DOI":"10.1080\/02713683.2019.1597890"},{"key":"e_1_3_2_15_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20201030-03"},{"key":"e_1_3_2_16_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.biomaterials.2011.01.057"},{"key":"e_1_3_2_17_2","doi-asserted-by":"publisher","DOI":"10.3390\/jfb4030114"},{"key":"e_1_3_2_18_2","volume-title":"ISO ISO 10993-12: 2021 Biological evaluation of medical devices\u2013Part 12: Sample preparation and reference materials","year":"2021","unstructured":"ISO ISO 10993-12: 2021 Biological evaluation of medical devices\u2013Part 12: Sample preparation and reference materials; International Organization for Standardization (ISO): Geneva S, 2021."},{"issue":"12","key":"e_1_3_2_19_2","first-page":"2827","article-title":"Cell death during corneal storage at 4 degrees C","volume":"40","author":"Komuro A","year":"1999","unstructured":"Komuro A, Hodge DO, Gores GJ, Bourne WM. Cell death during corneal storage at 4 degrees C. Invest Ophthalmol Vis Sci. 1999;40(12):2827\u20132832. PMID:10549642","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"e_1_3_2_20_2","doi-asserted-by":"publisher","DOI":"10.1097\/ICO.0000000000002846"},{"key":"e_1_3_2_21_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.exer.2020.108357"},{"key":"e_1_3_2_22_2","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0113332"},{"key":"e_1_3_2_23_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.cell.2010.02.014"},{"key":"e_1_3_2_24_2","doi-asserted-by":"publisher","DOI":"10.1189\/jlb.0306164"},{"key":"e_1_3_2_25_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.it.2007.08.004"},{"key":"e_1_3_2_26_2","doi-asserted-by":"publisher","DOI":"10.1089\/ten.tec.2011.0072"},{"key":"e_1_3_2_27_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1755-3768.2011.02300.x"},{"key":"e_1_3_2_28_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.exer.2012.12.012"},{"key":"e_1_3_2_29_2","doi-asserted-by":"publisher","DOI":"10.1167\/tvst.4.2.13"},{"key":"e_1_3_2_30_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.actbio.2022.07.035"},{"key":"e_1_3_2_31_2","doi-asserted-by":"publisher","DOI":"10.3109\/02713683.2015.1062114"},{"key":"e_1_3_2_32_2","doi-asserted-by":"publisher","unstructured":"Oh JY Kim MK Lee HJ Ko JH Wee WR Lee JH. Comparative observation of freeze-thaw-induced damage in pig rabbit and human corneal stroma. Vet Ophthalmol. 2009;12(s1)(suppl 1):50\u201356. 10.1111\/j.1463-5224.2009.00723.x PMID:19891652","DOI":"10.1111\/j.1463-5224.2009.00723.x"},{"issue":"8","key":"e_1_3_2_33_2","first-page":"1511","article-title":"Cryopreservation and culture of human corneal keratocytes","volume":"39","author":"Borderie VM","year":"1998","unstructured":"Borderie VM, Lopez M, Lombet A, Carvajal-Gonzalez S, Cywiner C, Laroche L. Cryopreservation and culture of human corneal keratocytes. Invest Ophthalmol Vis Sci. 1998;39(8):1511\u20131519. PMID:9660502","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"e_1_3_2_34_2","first-page":"878","article-title":"Decellularizing corneal stroma using N2 gas","volume":"14","author":"Amano S","year":"2008","unstructured":"Amano S, Shimomura N, Yokoo S, Araki-Sasaki K, Yamagami S. Decellularizing corneal stroma using N2 gas. Mol Vis. 2008;14:878\u2013882. PMID:18490960","journal-title":"Mol Vis"},{"key":"e_1_3_2_35_2","doi-asserted-by":"publisher","DOI":"10.2147\/OPTH.S9880"},{"key":"e_1_3_2_36_2","doi-asserted-by":"publisher","DOI":"10.4161\/org.5.3.10021"}],"container-title":["Journal of Refractive Surgery"],"original-title":[],"language":"en","deposited":{"date-parts":[[2025,6,9]],"date-time":"2025-06-09T12:55:07Z","timestamp":1749473707000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.healio.com\/doi\/10.3928\/1081597X-20250417-04"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,6]]},"references-count":35,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2025,6]]}},"alternative-id":["10.3928\/1081597X-20250417-04"],"URL":"https:\/\/doi.org\/10.3928\/1081597x-20250417-04","relation":{},"ISSN":["1081-597X"],"issn-type":[{"value":"1081-597X","type":"print"}],"subject":[],"published":{"date-parts":[[2025,6]]}}}