{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,8]],"date-time":"2026-10-08T05:22:14Z","timestamp":1791436934378,"version":"4.3.3"},"reference-count":49,"publisher":"SLACK, Inc.","issue":"1","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Refract Surg"],"published-print":{"date-parts":[[2026,1]]},"abstract":"<jats:sec>\n                    <jats:title>Purpose:<\/jats:title>\n                    <jats:p>To evaluate the long-term safety and efficacy of simultaneous total corneal wavefront-guided transepithelial photorefractive keratectomy (TCWG-TransPRK) with accelerated corneal cross-linking (CXL) in mild to moderate keratoconus, incorporating corneal biomechanics as objective markers of structural stability.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>\n                      This prospective, interventional, single-center study included patients with mild to moderate keratoconus. All underwent TCWG-TransPRK (maximum planned stromal ablation: 55 \u00b5m) followed by accelerated CXL (30 mW\/cm\n                      <jats:sup>2<\/jats:sup>\n                      for 3 minutes; total fluence: 5.4 J\/cm\n                      <jats:sup>2<\/jats:sup>\n                      ). Follow-up was conducted at 24 hours, 1 week, and 1, 3, 6, and 12 months. Primary outcomes were safety and efficacy, with stress-strain index version 2 (SSI v2) proposed as a key objective marker of biomechanical stability. Additionally, refractive accuracy, tomography, and epithelial remodeling were evaluated.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      Thirty-eight eyes from 19 patients were analyzed. At 12 months, uncorrected distance visual acuity improved from 0.80 \u00b1 0.36 to \u22120.03 \u00b1 0.10 logarithm of the minimum angle of resolution (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; .0001), with 87% achieving 20\/20 and all 20\/40 or better. Corrected distance visual acuity improved (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; .0001), with no Snellen line loss. Refractive accuracy was high (89% within \u00b11.00 diopter). SSI v2 increased significantly (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; .0001), indicating enhanced intrinsic stiffness. No keratoconus progression was observed. Epithelial thickness increased nasally and temporally, correlating with changes in spherical aberration and vertical trefoil.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions:<\/jats:title>\n                    <jats:p>Despite the use of accelerated CXL parameters, TCWG-TransPRK with CXL improved vision and enhanced biomechanical stability, as evidenced by a significant increase in SSI v2. This provides an objective structural marker for monitoring and customizing keratoconus care. These findings support the procedure as a safe and effective option for non-progressive mild to moderate keratoconus.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.3928\/1081597x-20251202-05","type":"journal-article","created":{"date-parts":[[2026,1,12]],"date-time":"2026-01-12T16:25:02Z","timestamp":1768235102000},"source":"Crossref","is-referenced-by-count":3,"title":["Biomechanical, Visual, and Refractive Outcomes of Total Corneal Wavefront-Guided Transepithelial PRK With Accelerated CXL in Keratoconus Using Objective Stability Markers"],"prefix":"10.3928","volume":"42","author":[{"given":"Luis","family":"Haro-Morlett","sequence":"first","affiliation":[{"name":"Cornea, Instituto de Oftalmologia Fundacion Conde de Valenciana IAP, Mexico City, Mexico"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Samuel","family":"Arba-Mosquera","sequence":"additional","affiliation":[{"name":"SCHWIND eye-tech-solutions, Kleinostheim, Germany."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Angelica","family":"Hernandez-Solis","sequence":"additional","affiliation":[{"name":"Cornea, Instituto de Oftalmologia Fundacion Conde de Valenciana IAP, Mexico City, Mexico"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Aldo","family":"Hernandez","sequence":"additional","affiliation":[{"name":"Cornea, Instituto de Oftalmologia Fundacion Conde de Valenciana IAP, Mexico City, Mexico"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Arturo","family":"Ramirez-Miranda","sequence":"additional","affiliation":[{"name":"Cornea, Instituto de Oftalmologia Fundacion Conde de Valenciana IAP, Mexico City, Mexico"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alejandro","family":"Navas","sequence":"additional","affiliation":[{"name":"Cornea, Instituto de Oftalmologia Fundacion Conde de Valenciana IAP, Mexico City, Mexico"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Enrique O.","family":"Graue-Hernandez","sequence":"additional","affiliation":[{"name":"Cornea, Instituto de Oftalmologia Fundacion Conde de Valenciana IAP, Mexico City, Mexico"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"2308","reference":[{"key":"e_1_3_2_2_2","doi-asserted-by":"publisher","DOI":"10.3389\/fmed.2023.1212314"},{"key":"e_1_3_2_3_2","doi-asserted-by":"publisher","DOI":"10.1097\/ICO.0000000000002781"},{"key":"e_1_3_2_4_2","doi-asserted-by":"publisher","DOI":"10.1080\/02713683.2022.2041042"},{"key":"e_1_3_2_5_2","doi-asserted-by":"publisher","DOI":"10.1097\/ICO.0000000000000408"},{"key":"e_1_3_2_6_2","doi-asserted-by":"publisher","DOI":"10.1177\/25158414241232258"},{"key":"e_1_3_2_7_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20160629-01"},{"key":"e_1_3_2_8_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(03)00407-3"},{"key":"e_1_3_2_9_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20161221-03"},{"key":"e_1_3_2_10_2","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-024-81809-w"},{"key":"e_1_3_2_11_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2022.12.016"},{"key":"e_1_3_2_12_2","doi-asserted-by":"publisher","DOI":"10.4103\/ijo.IJO_2078_20"},{"key":"e_1_3_2_13_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2014.02.036"},{"key":"e_1_3_2_14_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20151021-02"},{"key":"e_1_3_2_15_2","doi-asserted-by":"publisher","DOI":"10.1097\/ICO.0000000000003225"},{"key":"e_1_3_2_16_2","doi-asserted-by":"publisher","DOI":"10.1097\/ICO.0b013e318074e424"},{"key":"e_1_3_2_17_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20240715-03"},{"key":"e_1_3_2_18_2","doi-asserted-by":"publisher","DOI":"10.2147\/OPTH.S294775"},{"key":"e_1_3_2_19_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20190514-01"},{"key":"e_1_3_2_20_2","doi-asserted-by":"publisher","DOI":"10.1097\/j.jcrs.0000000000000110"},{"key":"e_1_3_2_21_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20190627-01"},{"key":"e_1_3_2_22_2","doi-asserted-by":"publisher","DOI":"10.1186\/s12886-023-03087-w"},{"key":"e_1_3_2_23_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.clae.2022.101717"},{"key":"e_1_3_2_24_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1755-3768.2012.02509.x"},{"key":"e_1_3_2_25_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00417-023-06167-1"},{"key":"e_1_3_2_26_2","volume-title":"Presented in the Lamellar Keratoplasty session at the IX World Cornea Congress","author":"Gomes J","unstructured":"Gomes J. The II global consensus on keratoconus. Presented in the Lamellar Keratoplasty session at the IX World Cornea Congress; March 20\u201322, 2025; Washington, D.C."},{"key":"e_1_3_2_27_2","doi-asserted-by":"publisher","DOI":"10.2147\/OPTH.S392665"},{"key":"e_1_3_2_28_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2014.01.040"},{"key":"e_1_3_2_29_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20160531-02"},{"key":"e_1_3_2_30_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2017.06.047"},{"key":"e_1_3_2_31_2","doi-asserted-by":"publisher","DOI":"10.1097\/ICO.0000000000000843"},{"key":"e_1_3_2_32_2","doi-asserted-by":"publisher","DOI":"10.2147\/OPTH.S156500"},{"key":"e_1_3_2_33_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2018.03.026"},{"key":"e_1_3_2_34_2","doi-asserted-by":"publisher","DOI":"10.1097\/ICO.0000000000003168"},{"key":"e_1_3_2_35_2","doi-asserted-by":"publisher","DOI":"10.1097\/ICO.0000000000003320"},{"key":"e_1_3_2_36_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081-597X-20050301-07"},{"key":"e_1_3_2_37_2","doi-asserted-by":"publisher","DOI":"10.2147\/OPTH.S44745"},{"key":"e_1_3_2_38_2","doi-asserted-by":"publisher","DOI":"10.1097\/ICU.0000000000000867"},{"key":"e_1_3_2_39_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20210830-03"},{"key":"e_1_3_2_40_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00417-024-06549-z"},{"key":"e_1_3_2_41_2","doi-asserted-by":"publisher","DOI":"10.3389\/fbioe.2021.640434"},{"key":"e_1_3_2_42_2","doi-asserted-by":"publisher","DOI":"10.1186\/s40662-024-00392-3"},{"key":"e_1_3_2_43_2","doi-asserted-by":"publisher","DOI":"10.4103\/ijo.IJO_1980_22"},{"key":"e_1_3_2_44_2","doi-asserted-by":"publisher","DOI":"10.1177\/1120672120944798"},{"key":"e_1_3_2_45_2","doi-asserted-by":"publisher","DOI":"10.1167\/tvst.13.10.38"},{"key":"e_1_3_2_46_2","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.12-11387"},{"issue":"7","key":"e_1_3_2_47_2","first-page":"2165","article-title":"UV absorbance of the human cornea in the 240- to 400-nm range","volume":"43","author":"Kolozsv\u00e1ri L","year":"2002","unstructured":"Kolozsv\u00e1ri L, N\u00f3gr\u00e1di A, Hopp B, Bor Z. UV absorbance of the human cornea in the 240- to 400-nm range. Invest Ophthalmol Vis Sci. 2002;43(7):2165\u20132168. PMID:12091412","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"e_1_3_2_48_2","doi-asserted-by":"publisher","DOI":"10.2174\/1874364101509010017"},{"key":"e_1_3_2_49_2","doi-asserted-by":"publisher","DOI":"10.2147\/OPTH.S188517"},{"key":"e_1_3_2_50_2","doi-asserted-by":"publisher","DOI":"10.2147\/OPTH.S117372"}],"container-title":["Journal of Refractive Surgery"],"original-title":[],"language":"en","deposited":{"date-parts":[[2026,1,12]],"date-time":"2026-01-12T16:25:14Z","timestamp":1768235114000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.healio.com\/doi\/10.3928\/1081597X-20251202-05"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,1]]},"references-count":49,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2026,1]]}},"alternative-id":["10.3928\/1081597X-20251202-05"],"URL":"https:\/\/doi.org\/10.3928\/1081597x-20251202-05","relation":{},"ISSN":["1081-597X"],"issn-type":[{"value":"1081-597X","type":"print"}],"subject":[],"published":{"date-parts":[[2026,1]]}}}