{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,8]],"date-time":"2026-10-08T05:22:17Z","timestamp":1791436937992,"version":"4.3.3"},"reference-count":25,"publisher":"SLACK, Inc.","issue":"3","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Refract Surg"],"published-print":{"date-parts":[[2026,3,1]]},"abstract":"<jats:sec>\n                    <jats:title>Purpose:<\/jats:title>\n                    <jats:p>To evaluate the effect of anterior capsule polishing (ACP) on postoperative formation of the capsule\u2013intraocular lens (C-IOL) complex in patients with cataract who have normal axial length.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>In this prospective randomized controlled trial, patients were assigned to either 360\u00b0 ACP or no polishing. Primary outcomes (capsular bend index [CBI], adhesion index [AI], and continuous curvilinear capsulorhexis diameter [CCCD]) and secondary outcomes (IOL tilt and decentration) were quantitatively assessed at 1 week, 1 month, and 3 months postoperatively using 14-meridian swept-source optical coherence tomography (SS-OCT) (CASIA 2; Tomey). Additional secondary outcomes were root mean square (RMS), corrected distance visual acuity (CDVA), and spherical equivalent refraction (SER).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      Forty-five eyes were enrolled (23 ACP, 22 control), and 40 (20 per group) completed a 3-month follow-up. At 3 months, the ACP group showed lower CBI (3.16 vs 3.68;\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = .001) and AI (0.00 vs 0.32;\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = .023), larger CCCD (5.30 vs 5.04 mm;\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = .025), and less CCCD contraction (0.11 vs 0.22 mm;\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = .034). Between-visit changes in CBI and AI did not differ between groups. Vertical tilt and its RMS were greater with ACP (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = .012 and .009, respectively), whereas horizontal tilt, decentration, CDVA, and SER were comparable.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions:<\/jats:title>\n                    <jats:p>ACP slows early C-IOL structural maturation (reduced capsular-bend kinetics and delayed capsule\u2013IOL adhesion) without compromising early refractive stability and stabilizes the capsulorhexis, but increases vertical IOL tilt. These findings support selective use in eyes prone to contraction and caution when precise IOL alignment is required.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.3928\/1081597x-20260112-10","type":"journal-article","created":{"date-parts":[[2026,3,7]],"date-time":"2026-03-07T14:16:49Z","timestamp":1772893009000},"source":"Crossref","is-referenced-by-count":2,"title":["Effect of Anterior Capsule Polishing on the Capsule\u2013IOL Complex in Patients With Normal Axial Length: A Prospective Randomized Controlled Trial"],"prefix":"10.3928","volume":"42","author":[{"given":"Wenkai","family":"Huang","sequence":"first","affiliation":[{"name":"National Clinical Research Center for Ocular Diseases, Eye Hospital, Wenzhou Medical University, Wenzhou, Zhejiang, China"},{"name":"Eye Hospital and School of Ophthalmology and Optometry, Wenzhou Medical University, Wenzhou, Zhejiang, China;"},{"name":"Shidong Hospital Affiliated to University of Shanghai for Science and Technology Shanghai, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chenyuan","family":"Zhu","sequence":"additional","affiliation":[{"name":"National Clinical Research Center for Ocular Diseases, Eye Hospital, Wenzhou Medical University, Wenzhou, Zhejiang, China"},{"name":"Eye Hospital and School of Ophthalmology and Optometry, Wenzhou Medical University, Wenzhou, Zhejiang, China;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xuechuan","family":"Miao","sequence":"additional","affiliation":[{"name":"National Clinical Research Center for Ocular Diseases, Eye Hospital, Wenzhou Medical University, Wenzhou, Zhejiang, China"},{"name":"Eye Hospital and School of Ophthalmology and Optometry, Wenzhou Medical University, Wenzhou, Zhejiang, China;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Er","family":"Mo","sequence":"additional","affiliation":[{"name":"Eye Hospital of Wenzhou Medical University Hangzhou Branch, Hangzhou, Zhejiang, China."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zhexuan","family":"Liu","sequence":"additional","affiliation":[{"name":"National Clinical Research Center for Ocular Diseases, Eye Hospital, Wenzhou Medical University, Wenzhou, Zhejiang, China"},{"name":"Eye Hospital and School of Ophthalmology and Optometry, Wenzhou Medical University, Wenzhou, Zhejiang, China;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jin","family":"Li","sequence":"additional","affiliation":[{"name":"National Clinical Research Center for Ocular Diseases, Eye Hospital, Wenzhou Medical University, Wenzhou, Zhejiang, China"},{"name":"Eye Hospital and School of Ophthalmology and Optometry, Wenzhou Medical University, Wenzhou, Zhejiang, China;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Junyong","family":"Cai","sequence":"additional","affiliation":[{"name":"National Clinical Research Center for Ocular Diseases, Eye Hospital, Wenzhou Medical University, Wenzhou, Zhejiang, China"},{"name":"Eye Hospital and School of Ophthalmology and Optometry, Wenzhou Medical University, Wenzhou, Zhejiang, China;"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"2308","reference":[{"key":"e_1_3_3_2_2","doi-asserted-by":"publisher","DOI":"10.1080\/02713683.2019.1570275"},{"key":"e_1_3_3_3_2","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.13-12849"},{"key":"e_1_3_3_4_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20200420-01"},{"key":"e_1_3_3_5_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0161-6420(02)01112-0"},{"key":"e_1_3_3_6_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0161-6420(97)30231-0"},{"key":"e_1_3_3_7_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(01)01094-X"},{"key":"e_1_3_3_8_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2012.08.019"},{"key":"e_1_3_3_9_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20210222-01"},{"key":"e_1_3_3_10_2","doi-asserted-by":"publisher","DOI":"10.1097\/j.jcrs.0000000000001407"},{"key":"e_1_3_3_11_2","doi-asserted-by":"publisher","DOI":"10.1080\/09273948.2019.1578888"},{"key":"e_1_3_3_12_2","doi-asserted-by":"publisher","DOI":"10.1159\/000084508"},{"key":"e_1_3_3_13_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2015.09.027"},{"key":"e_1_3_3_14_2","doi-asserted-by":"publisher","DOI":"10.3390\/ijms19103093"},{"key":"e_1_3_3_15_2","doi-asserted-by":"publisher","DOI":"10.1155\/2018\/8676451"},{"key":"e_1_3_3_16_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2009.08.020"},{"key":"e_1_3_3_17_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2022.01.013"},{"key":"e_1_3_3_18_2","doi-asserted-by":"publisher","DOI":"10.1186\/s12886-025-03884-5"},{"key":"e_1_3_3_19_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2018.04.035"},{"issue":"4","key":"e_1_3_3_20_2","first-page":"270","article-title":"[Comparative study of the tilt, decentration and higher-order aberrations (HOA) of single-piece and 3-piece Tecnis aspheric intraocular lenses]","volume":"51","author":"Yu F","year":"2015","unstructured":"Yu F, Chang P, Li J, Zhou Y, Zhao Y. [Comparative study of the tilt, decentration and higher-order aberrations (HOA) of single-piece and 3-piece Tecnis aspheric intraocular lenses]. Zhonghua Yan Ke Za Zhi. 2015;51(4):270\u2013275. PMID:26081230","journal-title":"Zhonghua Yan Ke Za Zhi"},{"key":"e_1_3_3_21_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20171004-02"},{"key":"e_1_3_3_22_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2018.10.045"},{"key":"e_1_3_3_23_2","doi-asserted-by":"publisher","DOI":"10.1097\/j.jcrs.0000000000000219"},{"key":"e_1_3_3_24_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(13)80004-1"},{"key":"e_1_3_3_25_2","doi-asserted-by":"publisher","DOI":"10.1097\/j.jcrs.0000000000001418"},{"key":"e_1_3_3_26_2","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-024-83387-3"}],"container-title":["Journal of Refractive Surgery"],"original-title":[],"language":"en","deposited":{"date-parts":[[2026,7,20]],"date-time":"2026-07-20T18:35:47Z","timestamp":1784572547000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.healio.com\/doi\/10.3928\/1081597X-20260112-10"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,3,1]]},"references-count":25,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2026,3,1]]}},"alternative-id":["10.3928\/1081597X-20260112-10"],"URL":"https:\/\/doi.org\/10.3928\/1081597x-20260112-10","relation":{},"ISSN":["1081-597X"],"issn-type":[{"value":"1081-597X","type":"print"}],"subject":[],"published":{"date-parts":[[2026,3,1]]}}}