{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,15]],"date-time":"2026-08-15T10:42:03Z","timestamp":1786790523890,"version":"build-2736575974"},"reference-count":22,"publisher":"SLACK, Inc.","issue":"4","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Refract Surg"],"published-print":{"date-parts":[[2026,4,1]]},"abstract":"<jats:sec>\n                    <jats:title>Purpose:<\/jats:title>\n                    <jats:p>To compare the visual performance of a new multifocal-extended depth-of-focus (EDOF) intraocular lens (IOL) (TECNIS Odyssey, Johnson &amp; Johnson) with that of an earlier multifocal\u2013EDOF IOL (TECNIS Synergy; Johnson &amp; Johnson) and a trifocal IOL (PanOptix; Alcon Laboratories, Inc).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>Ninety eyes of 90 patients who received one of two types of multifocal\u2013EDOF IOLs or a trifocal IOL were enrolled. Uncorrected and corrected distance visual acuity at various distances, photopic and mesopic contrast visual acuity, and degree of photic symptoms were evaluated at 3 months postoperatively and compared among groups.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      Mean uncorrected far and intermediate visual acuities from infinity to 1 m were generally better in the Odyssey group than in the other groups (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      \u2a7d .046), but uncorrected near visual acuity at 0.3 m and intermediate visual acuity at 0.5 m were worse (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      \u2a7d .028). However, mean distance-corrected far and intermediate visual acuities from infinity to 1 m, did not differ significantly among groups, and near visual acuity and intermediate visual acuity at 0.5 and 0.7 m were significantly worse, in the Odyssey group than in the other groups (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      \u2a7d .018). Mean mesopic contrast visual acuity at 10% contrast and glare size were significantly better in the Odyssey group than in the other groups (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      \u2a7d .040).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions:<\/jats:title>\n                    <jats:p>The Odyssey provided better uncorrected far and intermediate visual acuities from infinity to 1 m than the other IOLs despite no significant difference in distance-corrected visual acuity. However, it showed worse uncorrected and distance-corrected near visual acuity and intermediate visual acuities at 0.5 m, suggesting that the Odyssey has far-dominant properties and greater tolerance to refractive errors.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.3928\/1081597x-20260212-01","type":"journal-article","created":{"date-parts":[[2026,4,7]],"date-time":"2026-04-07T18:22:24Z","timestamp":1775586144000},"source":"Crossref","is-referenced-by-count":2,"title":["Comparison of Visual Performance Among Two Multifocal\u2013Extended Depth-of-Focus Intraocular Lens Types and a Trifocal Intraocular Lens"],"prefix":"10.3928","volume":"42","author":[{"given":"Ken","family":"Hayashi","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Koichi","family":"Uno","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shunsuke","family":"Hayashi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Motoaki","family":"Yoshida","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"2308","reference":[{"key":"e_1_3_2_2_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2023.01.024"},{"key":"e_1_3_2_3_2","doi-asserted-by":"publisher","DOI":"10.1001\/jamaophthalmol.2022.3667"},{"key":"e_1_3_2_4_2","doi-asserted-by":"publisher","DOI":"10.1002\/14651858.CD014891.pub2"},{"key":"e_1_3_2_5_2","doi-asserted-by":"publisher","DOI":"10.2147\/OPTH.S377234"},{"key":"e_1_3_2_6_2","doi-asserted-by":"publisher","DOI":"10.1097\/j.jcrs.0000000000001142"},{"key":"e_1_3_2_7_2","doi-asserted-by":"publisher","DOI":"10.2147\/OPTH.S400083"},{"key":"e_1_3_2_8_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20250221-02"},{"key":"e_1_3_2_9_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20230424-01"},{"key":"e_1_3_2_10_2","doi-asserted-by":"publisher","DOI":"10.1097\/j.jcrs.0000000000000743"},{"key":"e_1_3_2_11_2","doi-asserted-by":"publisher","DOI":"10.1038\/s41433-022-02188-y"},{"key":"e_1_3_2_12_2","doi-asserted-by":"publisher","DOI":"10.1097\/j.jcrs.0000000000000971"},{"key":"e_1_3_2_13_2","doi-asserted-by":"publisher","DOI":"10.1097\/j.jcrs.0000000000001678"},{"key":"e_1_3_2_14_2","doi-asserted-by":"publisher","DOI":"10.3390\/jcm11247374"},{"key":"e_1_3_2_15_2","doi-asserted-by":"publisher","DOI":"10.1364\/BOE.544647"},{"key":"e_1_3_2_16_2","doi-asserted-by":"publisher","DOI":"10.1097\/j.jcrs.0000000000000767"},{"key":"e_1_3_2_17_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2014.10.023"},{"key":"e_1_3_2_18_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2020.07.051"},{"key":"e_1_3_2_19_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2012.02.032"},{"key":"e_1_3_2_20_2","doi-asserted-by":"publisher","DOI":"10.1097\/j.jcrs.0000000000001734"},{"key":"e_1_3_2_21_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20220516-02"},{"key":"e_1_3_2_22_2","doi-asserted-by":"publisher","DOI":"10.3390\/jcm12134365"},{"key":"e_1_3_2_23_2","doi-asserted-by":"publisher","DOI":"10.2147\/OPTH.S504090"}],"container-title":["Journal of Refractive Surgery"],"original-title":[],"language":"en","deposited":{"date-parts":[[2026,7,20]],"date-time":"2026-07-20T18:41:47Z","timestamp":1784572907000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.healio.com\/doi\/10.3928\/1081597X-20260212-01"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,4,1]]},"references-count":22,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2026,4,1]]}},"alternative-id":["10.3928\/1081597X-20260212-01"],"URL":"https:\/\/doi.org\/10.3928\/1081597x-20260212-01","relation":{},"ISSN":["1081-597X"],"issn-type":[{"value":"1081-597X","type":"print"}],"subject":[],"published":{"date-parts":[[2026,4,1]]}}}