{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,20]],"date-time":"2026-07-20T19:04:06Z","timestamp":1784574246565,"version":"3.55.0"},"reference-count":42,"publisher":"SLACK, Inc.","issue":"5","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Refract Surg"],"published-print":{"date-parts":[[2026,5,1]]},"abstract":"<jats:sec>\n                    <jats:title>Purpose:<\/jats:title>\n                    <jats:p>To evaluate the visual and refractive outcomes of three different partial range of field intraocular lenses (PRoF IOLs) using a mini-monvision strategy.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>This was a single-center, prospective, randomized double-blind study enrolling 105 patients who underwent bilateral cataract surgery with implantation of either Isopure (BVI Medical, n = 36), Tecnis Eyhance (Johnson &amp; Johnson, n = 35), or AcrySof IQ Vivity (Alcon Laboratories, Inc, n = 34) IOLs. Binocular and monocular (dominant eye) visual acuity at distance, intermediate, and near ranges, defocus curves, and spectacle independence (PRSIQ) were assessed over a 6-month follow-up. Mini-monovision (\u22120.50 diopters [D] in the non-dominant eye) was employed.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      At 6 months, binocular uncorrected distance visual acuity was excellent (Isopure: \u22120.06 \u00b1 0.09; Vivity: \u22120.01 \u00b1 0.09; Eyhance: \u22120.05 \u00b1 0.07 logarithm of the minimum angle of resolution [logMAR];\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = .077). Binocular uncorrected intermediate visual acuity was similar across the three groups (Isopure: 0.07 \u00b1 0.10; Vivity: 0.05 \u00b1 0.08; Eyhance: 0.06 \u00b1 0.11 logMAR;\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = .592). Vivity showed better binocular uncorrected near visual acuity than Isopure and Eyhance (Isopure: 0.29 \u00b1 0.13; Vivity: 0.19 \u00b1 0.12; Eyhance: 0.30 \u00b1 0.15 logMAR;\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      \u2264 .012). Monocular uncorrected and corrected distance visual acuity were significantly worse in the Vivity group (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; .001 vs Vivity). All IOLs maintained binocular visual acuity \u22640.20 logMAR from +1.00 to \u22121.50 diopters (D), with Vivity showing superior performance at \u22121.50 and \u22122.00 D. Spectacle independence was high for distance (\u226585%) and intermediate (\u226592%) tasks in all groups. Most patients required near correction at least occasionally.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions:<\/jats:title>\n                    <jats:p>All three PRoF IOLs provided excellent distance and intermediate vision with functional near vision using a mini-monvision strategy. Vivity offered slightly better near acuity and defocus performance, whereas Isopure and Eyhance tended to show superior distance vision.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.3928\/1081597x-20260216-02","type":"journal-article","created":{"date-parts":[[2026,5,11]],"date-time":"2026-05-11T18:21:48Z","timestamp":1778523708000},"source":"Crossref","is-referenced-by-count":0,"title":["A Prospective, Randomized Comparison of Three Partial Range of Field Intraocular Lenses Using a Mini-monovision Strategy"],"prefix":"10.3928","volume":"42","author":[{"given":"Kristof","family":"Vandekerckhove","sequence":"first","affiliation":[{"name":"Vista Alpina Eye Clinic, Visp, Switzerland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mark","family":"Rabinovich","sequence":"additional","affiliation":[{"name":"Vista Alpina Eye Clinic, Visp, Switzerland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"David P.","family":"Pi\u00f1ero","sequence":"additional","affiliation":[{"name":"Department of Optics, Pharmacology and Anatomy, University of Alicante, Alicante, Spain."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"2308","reference":[{"key":"e_1_3_2_2_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20231212-01"},{"key":"e_1_3_2_3_2","doi-asserted-by":"publisher","DOI":"10.1186\/s12886-023-02844-1"},{"key":"e_1_3_2_4_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2016.09.039"},{"key":"e_1_3_2_5_2","doi-asserted-by":"publisher","DOI":"10.1097\/j.jcrs.0000000000001479"},{"key":"e_1_3_2_6_2","doi-asserted-by":"publisher","DOI":"10.3390\/diagnostics12112667"},{"key":"e_1_3_2_7_2","doi-asserted-by":"publisher","DOI":"10.1097\/j.jcrs.0000000000001502"},{"key":"e_1_3_2_8_2","doi-asserted-by":"publisher","DOI":"10.1186\/s12886-022-02584-8"},{"key":"e_1_3_2_9_2","doi-asserted-by":"publisher","DOI":"10.1159\/000519139"},{"key":"e_1_3_2_10_2","doi-asserted-by":"publisher","DOI":"10.18240\/ijo.2025.04.05"},{"key":"e_1_3_2_11_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20250204-02"},{"key":"e_1_3_2_12_2","doi-asserted-by":"publisher","DOI":"10.1186\/s40662-024-00424-y"},{"key":"e_1_3_2_13_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2024.10.014"},{"key":"e_1_3_2_14_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20240501-02"},{"key":"e_1_3_2_15_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20240903-01"},{"key":"e_1_3_2_16_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20230124-02"},{"key":"e_1_3_2_17_2","doi-asserted-by":"publisher","DOI":"10.2147\/OPTH.S425352"},{"key":"e_1_3_2_18_2","doi-asserted-by":"publisher","DOI":"10.1080\/02713683.2022.2074046"},{"key":"e_1_3_2_19_2","doi-asserted-by":"publisher","DOI":"10.1155\/2022\/5100861"},{"key":"e_1_3_2_20_2","doi-asserted-by":"publisher","DOI":"10.1155\/2022\/4119698"},{"key":"e_1_3_2_21_2","doi-asserted-by":"publisher","DOI":"10.2147\/OPTH.S344379"},{"key":"e_1_3_2_22_2","doi-asserted-by":"publisher","DOI":"10.2147\/OPTH.S297985"},{"key":"e_1_3_2_23_2","doi-asserted-by":"publisher","DOI":"10.1097\/j.jcrs.0000000000000068"},{"key":"e_1_3_2_24_2","doi-asserted-by":"publisher","DOI":"10.1177\/11206721231154818"},{"key":"e_1_3_2_25_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2017.03.018"},{"key":"e_1_3_2_26_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00417-024-06590-y"},{"key":"e_1_3_2_27_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00417-021-05426-3"},{"key":"e_1_3_2_28_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20200612-01"},{"key":"e_1_3_2_29_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20091016-01"},{"key":"e_1_3_2_30_2","doi-asserted-by":"publisher","DOI":"10.1159\/000529234"},{"key":"e_1_3_2_31_2","doi-asserted-by":"publisher","DOI":"10.1186\/s12886-023-02839-y"},{"key":"e_1_3_2_32_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jfo.2025.104429"},{"key":"e_1_3_2_33_2","doi-asserted-by":"publisher","DOI":"10.1177\/11206721221125004"},{"key":"e_1_3_2_34_2","doi-asserted-by":"publisher","DOI":"10.1177\/11206721221146675"},{"key":"e_1_3_2_35_2","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-024-80663-0"},{"key":"e_1_3_2_36_2","doi-asserted-by":"publisher","DOI":"10.2147\/OPTH.S442752"},{"key":"e_1_3_2_37_2","doi-asserted-by":"publisher","DOI":"10.2147\/OPTH.S405267"},{"key":"e_1_3_2_38_2","doi-asserted-by":"publisher","DOI":"10.1097\/j.jcrs.0000000000000825"},{"key":"e_1_3_2_39_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2023.01.024"},{"key":"e_1_3_2_40_2","doi-asserted-by":"publisher","DOI":"10.1097\/j.jcrs.0000000000000096"},{"key":"e_1_3_2_41_2","doi-asserted-by":"publisher","DOI":"10.1097\/j.jcrs.0000000000000706"},{"key":"e_1_3_2_42_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20220802-01"},{"key":"e_1_3_2_43_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20230126-02"}],"container-title":["Journal of Refractive Surgery"],"original-title":[],"language":"en","deposited":{"date-parts":[[2026,7,20]],"date-time":"2026-07-20T18:44:27Z","timestamp":1784573067000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.healio.com\/doi\/10.3928\/1081597X-20260216-02"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,5,1]]},"references-count":42,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2026,5,1]]}},"alternative-id":["10.3928\/1081597X-20260216-02"],"URL":"https:\/\/doi.org\/10.3928\/1081597x-20260216-02","relation":{},"ISSN":["1081-597X"],"issn-type":[{"value":"1081-597X","type":"print"}],"subject":[],"published":{"date-parts":[[2026,5,1]]}}}